• Sign up now and get discount up to 47%

Schneider TeSys GV3-Circuit breaker-thermal-magnetic - 12…18A - EverLink BTR connectors - GV3P18

# of Pole : 3

P (kW) : 7.5

Icu (kA) : 100

Rp 3,686,199.00 Rp 1,916,823.00 1916823 IDR

Rp 3,686,199.00

Option not available

  • # of Pole
  • P (kW)
  • Icu (kA)

This combination does not exist.

Add to Cart

Schneider TeSys GV3-Circuit breaker-thermal-magnetic - 12…18A - EverLink BTR connectors - GV3P18
Terjual 0
0 (0 Rating)
Ulasan (0)

Rp 1,916,823.00
48.00 % Rp 3,686,199.00 1916823 IDR

Rp 3,686,199.00

Option not available

Atur Jumlah & Catatan
Stock Total: 2

# of Pole : 3

P (kW) : 7.5

Icu (kA) : 100

Spesifikasi

[Deskripsi] Pemutus sirkuit motor termal-magnetik dan magnetik hingga 80 A dan 45 kW. Pemutus sirkuit motor TeSys GV3 menyediakan isolasi, kontrol motor dan perlindungan arus berlebih termal dalam satuan lebar standar 55 mm. [Spesifikasi] 1. product name : TeSys GV3 2. device short name : GV3ME 3. device application : Motor 4. trip unit technology : Thermal-magnetic 5. poles description : 3P 6. network type : AC 7. utilisation category : -AC-3 conforming to IEC 60947-4-1 -Category A conforming to IEC 60947-2 8. network frequency : 50/60 Hz conforming to IEC 60947-4-1 9. fixing mode : -35 mm symmetrical DIN rail: clipped -Panel: screwed (with 2 x M4 screws) 10. operating position : Any position 11. motor power kW : -7.5 kW at 400/415 V AC 50/60 Hz -9 kW at 500 V AC 50/60 Hz -15 kW at 690 V AC 50/60 Hz 12. breaking capacity : -100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 -100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 -50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 -6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 -12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 13. [Ics] rated service short-circuit breaking capacity : -100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 -100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 -100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 -50 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 -60 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 14. control type : Push-button 15. [In] rated current : 18 A 16. thermal protection adjustment range : 12…18 A 17. magnetic tripping current : 252 A 18. [Ue] rated operational voltage : 690 V AC 50/60 Hz conforming to IEC 60947-2 19. [Ui] rated insulation voltage : 690 V AC 50/60 Hz conforming to IEC 60947-2 20. [Ith] conventional free air thermal current : 18 A conforming to IEC 60947-4-1 21. height : 132 mm 22. width : 55 mm 23. depth : 136 mm 24. net weight : 0.96 kg

Specifications for Schneider TeSys GV3-Circuit breaker-thermal-magnetic - 12…18A - EverLink BTR connectors - GV3P18

# of Pole 3
P (kW) 7.5
Icu (kA) 100

Filter By

Product Public Price Discount Guaranteed Stock QTY Action
Rp 309,840.00 100.00 % Out of Stock
  • # of Pole
  • P (kW)
Rp 235,555.00 100.00 % 105
  • # of Pole
  • P (kW)
Rp 6,180,396.00 100.00 % 20
  • # of Pole
Rp 2,838,312.00 100.00 % 12
  • # of Pole
Rp 2,143,990.00 100.00 % 16
  • # of Pole
Rp 2,516,187.00 100.00 % 2
  • # of Pole
  • P (kW)
  • [Ie] rated operational current

[Deskripsi] Pemutus sirkuit motor termal-magnetik dan magnetik hingga 80 A dan 45 kW. Pemutus sirkuit motor TeSys GV3 menyediakan isolasi, kontrol motor dan perlindungan arus berlebih termal dalam satuan lebar standar 55 mm. [Spesifikasi] 1. product name : TeSys GV3 2. device short name : GV3ME 3. device application : Motor 4. trip unit technology : Thermal-magnetic 5. poles description : 3P 6. network type : AC 7. utilisation category : -AC-3 conforming to IEC 60947-4-1 -Category A conforming to IEC 60947-2 8. network frequency : 50/60 Hz conforming to IEC 60947-4-1 9. fixing mode : -35 mm symmetrical DIN rail: clipped -Panel: screwed (with 2 x M4 screws) 10. operating position : Any position 11. motor power kW : -7.5 kW at 400/415 V AC 50/60 Hz -9 kW at 500 V AC 50/60 Hz -15 kW at 690 V AC 50/60 Hz 12. breaking capacity : -100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 -100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 -50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 -6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 -12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 13. [Ics] rated service short-circuit breaking capacity : -100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 -100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 -100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 -50 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 -60 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 14. control type : Push-button 15. [In] rated current : 18 A 16. thermal protection adjustment range : 12…18 A 17. magnetic tripping current : 252 A 18. [Ue] rated operational voltage : 690 V AC 50/60 Hz conforming to IEC 60947-2 19. [Ui] rated insulation voltage : 690 V AC 50/60 Hz conforming to IEC 60947-2 20. [Ith] conventional free air thermal current : 18 A conforming to IEC 60947-4-1 21. height : 132 mm 22. width : 55 mm 23. depth : 136 mm 24. net weight : 0.96 kg