                    | range | EasyPact  | |
|---|---|---|
| product name | EasyPact TVS  | |
| product or component type | Contactor  | |
| device short name | LC1E  | |
| contactor application | Resistive load Motor control  | |
| utilisation category | AC-1 AC-3  | |
| poles description | 3P  | |
| power pole contact composition | 3 NO  | |
| [Ue] rated operational voltage | Power circuit: <= 690 V AC 50/60 Hz  | |
| [Ie] rated operational current | 32 A (at <55 °C) at <= 440 V AC AC-3 for power circuit 50 A (at <60 °C) at <= 440 V AC AC-1 for power circuit  | |
| motor power kW | 7.5 kW at 220...230 V AC 50/60 Hz (AC-3) 15 kW at 380...400 V AC 50/60 Hz (AC-3) 15 kW at 415 V AC 50/60 Hz (AC-3) 15 kW at 440 V AC 50/60 Hz (AC-3) 18.5 kW at 500 V AC 50/60 Hz (AC-3) 18.5 kW at 660...690 V AC 50/60 Hz (AC-3)  | |
| control circuit type | AC at 50 Hz  | |
| [Uc] control circuit voltage | 380 V AC 50 Hz  | |
| height | 84 mm  | |
| width | 56 mm  | |
| depth | 86 mm  | |
| net weight | 0.45 kg  | |
| colour | Grey (RAL 7011)  | 
| auxiliary contact composition | 1 NO  | |
|---|---|---|
| [Uimp] rated impulse withstand voltage | 6 kV coil not connected to the power circuit conforming to IEC 60947  | |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1  | |
| overvoltage category | III  | |
| Irms rated making capacity | 320 A at 440 V AC for power circuit conforming to IEC 60947-4-1  | |
| rated breaking capacity | 256 A at 440 V for power circuit conforming to IEC 60947  | |
| [Icw] rated short-time withstand current | 260 A 40 °C - 10 s for power circuit 138 A 40 °C - 60 s for power circuit 60 A 40 °C - 600 s for power circuit  | |
| associated fuse rating | 10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1 63 A gG at <= 690 V coordination type 1 for power circuit  | |
| average impedance | 2.5 mOhm - Ith 50 A 50 Hz for power circuit  | |
| power dissipation per pole | 2 W AC-3 5 W AC-1  | |
| control circuit voltage limits | Operational: 0.85...1.1 Uc at 50 Hz (at <55 °C) Drop-out: 0.3...0.6 Uc at 50 Hz (at <55 °C)  | |
| operating time | 12...22 ms on closing 4...19 ms on opening  | |
| mechanical durability | 8000000 cycles  | |
| maximum operating rate | 1800 cyc/h 60 °C  | |
| inrush power in VA | 95 VA 50 Hz cos phi 0.75 (at 20 °C) 95 VA 60 Hz cos phi 0.75 (at 20 °C)  | |
| hold-in power consumption in VA | 8.3 VA 50 Hz cos phi 0.3 (at 20 °C) 8.5 VA 60 Hz cos phi 0.3 (at 20 °C)  | |
| heat dissipation | 2…3 W for control circuit  | |
| minimum switching current | 5 mA for control circuit  | |
| minimum switching voltage | 17 V for control circuit  | |
| non-overlap time | 1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact  | |
| insulation resistance | > 10 MOhm for control circuit  | |
| electrical durability | 1000000 cycles AC-3 350000 cycles AC-1  | |
| mounting support | DIN rail Plate  | |
| connections - terminals | Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 1 1.5…6 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 2 1.5…6 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 1 1…6 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible with cable end  | |
| Recommended tightening torque | Control circuit: 1.2 N.m Power circuit: 2.1 N.m  | |
| Max tightening torque | Control circuit: 1.4 N.m Power circuit: 2.3 N.m  | 
| standards | IEC 60947-4-1 IEC 60947-5-1 IEC 60947-1  | |
|---|---|---|
| product certifications | EAC CE  | |
| IP degree of protection | IP2x conforming to IEC 60529  | |
| protective treatment | TH (pollution degree 3) conforming to IEC 60068-2-30 test Db  | |
| pollution degree | 3  | |
| ambient air temperature for operation | -5…55 °C  | |
| ambient air temperature for storage | -60…80 °C  | |
| permissible ambient air temperature around the device | -20…70 °C at Uc  | |
| operating altitude | 3000 m without derating  | |
| fire resistance | 850 °C conforming to IEC 60695-2-1  | |
| mechanical robustness | Vibrations contactor open: 1.5 Gn, 5...300 Hz Vibrations contactor closed: 3 Gn, 5...300 Hz Shocks contactor closed: 10 Gn for 11 ms Shocks contactor open: 6 Gn for 11 ms  | 
| Package 1 Weight | 451.000 g  | |
|---|---|---|
| Package 1 Height | 8.600 cm  | |
| Package 1 width | 5.600 cm  | |
| Package 1 Length | 8.400 cm  | 
| Sustainable offer status | Green Premium product  | |
|---|---|---|
| REACh Regulation | ||
| REACh free of SVHC | Yes  | |
| EU RoHS Directive | Compliant EU RoHS Declaration  | |
| Toxic heavy metal free | Yes  | |
| Mercury free | Yes  | |
| RoHS exemption information | ||
| China RoHS Regulation | ||
| Environmental Disclosure | ||
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins  | 
| Warranty | 12 months  | 
|---|
| range | EasyPact  | |
|---|---|---|
| product name | EasyPact TVS  | |
| product or component type | Contactor  | |
| device short name | LC1E  | |
| contactor application | Resistive load Motor control  | |
| utilisation category | AC-1 AC-3  | |
| poles description | 3P  | |
| power pole contact composition | 3 NO  | |
| [Ue] rated operational voltage | Power circuit: <= 690 V AC 50/60 Hz  | |
| [Ie] rated operational current | 32 A (at <55 °C) at <= 440 V AC AC-3 for power circuit 50 A (at <60 °C) at <= 440 V AC AC-1 for power circuit  | |
| motor power kW | 7.5 kW at 220...230 V AC 50/60 Hz (AC-3) 15 kW at 380...400 V AC 50/60 Hz (AC-3) 15 kW at 415 V AC 50/60 Hz (AC-3) 15 kW at 440 V AC 50/60 Hz (AC-3) 18.5 kW at 500 V AC 50/60 Hz (AC-3) 18.5 kW at 660...690 V AC 50/60 Hz (AC-3)  | |
| control circuit type | AC at 50 Hz  | |
| [Uc] control circuit voltage | 380 V AC 50 Hz  | |
| height | 84 mm  | |
| width | 56 mm  | |
| depth | 86 mm  | |
| net weight | 0.45 kg  | |
| colour | Grey (RAL 7011)  | 
| auxiliary contact composition | 1 NO  | |
|---|---|---|
| [Uimp] rated impulse withstand voltage | 6 kV coil not connected to the power circuit conforming to IEC 60947  | |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1  | |
| overvoltage category | III  | |
| Irms rated making capacity | 320 A at 440 V AC for power circuit conforming to IEC 60947-4-1  | |
| rated breaking capacity | 256 A at 440 V for power circuit conforming to IEC 60947  | |
| [Icw] rated short-time withstand current | 260 A 40 °C - 10 s for power circuit 138 A 40 °C - 60 s for power circuit 60 A 40 °C - 600 s for power circuit  | |
| associated fuse rating | 10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1 63 A gG at <= 690 V coordination type 1 for power circuit  | |
| average impedance | 2.5 mOhm - Ith 50 A 50 Hz for power circuit  | |
| power dissipation per pole | 2 W AC-3 5 W AC-1  | |
| control circuit voltage limits | Operational: 0.85...1.1 Uc at 50 Hz (at <55 °C) Drop-out: 0.3...0.6 Uc at 50 Hz (at <55 °C)  | |
| operating time | 12...22 ms on closing 4...19 ms on opening  | |
| mechanical durability | 8000000 cycles  | |
| maximum operating rate | 1800 cyc/h 60 °C  | |
| inrush power in VA | 95 VA 50 Hz cos phi 0.75 (at 20 °C) 95 VA 60 Hz cos phi 0.75 (at 20 °C)  | |
| hold-in power consumption in VA | 8.3 VA 50 Hz cos phi 0.3 (at 20 °C) 8.5 VA 60 Hz cos phi 0.3 (at 20 °C)  | |
| heat dissipation | 2…3 W for control circuit  | |
| minimum switching current | 5 mA for control circuit  | |
| minimum switching voltage | 17 V for control circuit  | |
| non-overlap time | 1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact  | |
| insulation resistance | > 10 MOhm for control circuit  | |
| electrical durability | 1000000 cycles AC-3 350000 cycles AC-1  | |
| mounting support | DIN rail Plate  | |
| connections - terminals | Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 1 1.5…6 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 2 1.5…6 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 1 1…6 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible with cable end  | |
| Recommended tightening torque | Control circuit: 1.2 N.m Power circuit: 2.1 N.m  | |
| Max tightening torque | Control circuit: 1.4 N.m Power circuit: 2.3 N.m  | 
| standards | IEC 60947-4-1 IEC 60947-5-1 IEC 60947-1  | |
|---|---|---|
| product certifications | EAC CE  | |
| IP degree of protection | IP2x conforming to IEC 60529  | |
| protective treatment | TH (pollution degree 3) conforming to IEC 60068-2-30 test Db  | |
| pollution degree | 3  | |
| ambient air temperature for operation | -5…55 °C  | |
| ambient air temperature for storage | -60…80 °C  | |
| permissible ambient air temperature around the device | -20…70 °C at Uc  | |
| operating altitude | 3000 m without derating  | |
| fire resistance | 850 °C conforming to IEC 60695-2-1  | |
| mechanical robustness | Vibrations contactor open: 1.5 Gn, 5...300 Hz Vibrations contactor closed: 3 Gn, 5...300 Hz Shocks contactor closed: 10 Gn for 11 ms Shocks contactor open: 6 Gn for 11 ms  | 
| Package 1 Weight | 451.000 g  | |
|---|---|---|
| Package 1 Height | 8.600 cm  | |
| Package 1 width | 5.600 cm  | |
| Package 1 Length | 8.400 cm  | 
| Sustainable offer status | Green Premium product  | |
|---|---|---|
| REACh Regulation | ||
| REACh free of SVHC | Yes  | |
| EU RoHS Directive | Compliant EU RoHS Declaration  | |
| Toxic heavy metal free | Yes  | |
| Mercury free | Yes  | |
| RoHS exemption information | ||
| China RoHS Regulation | ||
| Environmental Disclosure | ||
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins  | 
| Warranty | 12 months  | 
|---|