[Deskripsi] -Kurva C (Magnetis trip antara 5 dan 10 In) -Lebar modul per kutub = 27 mm. -Dapat digunakan untuk jaringan listrik DC (Untuk 1 Pole hingga 144VDC, 2 Pole hingga 250VDC, 3 Pole hingga 375VDC, 4 Pole hingga 500VDC) -Koneksi kabel ke terminal : maksimum 35 mm2 kabel serabut atau 50 mm2 kabel tunggal. [Spesifikasi] 1. poles description : 3P 2. number of protected poles : 3 3. [In] rated current : 100 A at 30 C 4. network type : AC 5. trip unit technology : thermal-magnetic 6. curve code : C 7. breaking capacity : -6 kA Icu conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz -10 kA Icu conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz -20 kA Icu conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz -10 kA Icu conforming to EN/IEC 60947-2 - <= 250 V DC -10000 A Icn conforming to EN/IEC 60898-1 - 230...400 V AC 50/60 Hz 8. suitability for isolation : Yes conforming to IEC 60947-2 9. network frequency : 50/60 Hz 10. [Ue] rated operational voltage : -<= 375 V DC -220...240 V AC 50/60 Hz -380...415 V AC 50/60 Hz -440 V AC 50/60 Hz -230400 V AC 50/60 Hz 11. magnetic tripping limit : 5...10 x In 12. limitation class : 3 conforming to EN/IEC 60947-2 13. [Ui] rated insulation voltage : 500 V AC 50/60 Hz conforming to EN/IEC 60947-2 14. [Uimp] rated impulse withstand voltage : 6 kV conforming to EN/IEC 60947-2 15. contact position indicator : Yes 16. control type : Toggle 17. local signaling : ON/OFF indication 18. height : 81 mm 19. width : 81 mm 20. depth : 73 mm 21. product weight : 0.619 kg 22. colour : White
| range of product | C120 | |
|---|---|---|
| range | Acti 9 | |
| product name | C120 | |
| product or component type | Miniature circuit-breaker | |
| device short name | C120N | |
| device application | Distribution | |
| poles description | 3P | |
| number of protected poles | 3 | |
| [In] rated current | 100 A at 30 °C | |
| network type | AC | |
| trip unit technology | Thermal-magnetic | |
| curve code | C | |
| breaking capacity | 10000 A Icn at 230...400 V AC 50/60 Hz conforming to EN/IEC 60898-1 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at <= 375 V DC conforming to EN/IEC 60947-2 | |
| suitability for isolation | Yes conforming to IEC 60947-2 |
| network frequency | 50/60 Hz | |
|---|---|---|
| [Ue] rated operational voltage | <= 375 V DC 380...415 V AC 50/60 Hz 220...240 V AC 50/60 Hz 440 V AC 50/60 Hz 230...400 V AC 50/60 Hz | |
| magnetic tripping limit | 5...10 x In | |
| [Ics] rated service breaking capacity | 7500 A 75 % conforming to EN/IEC 60898-1 - 230...400 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 375 V DC | |
| limitation class | 3 conforming to EN/IEC 60947-2 | |
| [Ui] rated insulation voltage | 500 V AC 50/60 Hz conforming to EN/IEC 60947-2 | |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to EN/IEC 60947-2 | |
| contact position indicator | Yes | |
| control type | Toggle | |
| local signalling | ON/OFF indication | |
| mounting mode | Clip-on | |
| mounting support | 35 mm symmetrical DIN rail | |
| comb busbar and distribution block compatibility | NO | |
| 9 mm pitches | 9 | |
| height | 81 mm | |
| width | 81 mm | |
| depth | 73 mm | |
| net weight | 0.615 kg | |
| colour | White | |
| mechanical durability | 20000 cycles | |
| electrical durability | 5000 cycles conforming to IEC 60947-2 | |
| connections - terminals | Tunnel type terminals1…50 mm² rigid Tunnel type terminals1.5…35 mm² flexible | |
| wire stripping length | 15 mm | |
| tightening torque | 3.5 N.m | |
| earth-leakage protection | Separate block |
| standards | EN/IEC 60947-2 EN/IEC 60898-1 | |
|---|---|---|
| product certifications | EAC | |
| IP degree of protection | IP20 conforming to IEC 60529 | |
| pollution degree | 3 conforming to IEC 60947-2 | |
| overvoltage category | IV | |
| tropicalisation | 2 conforming to IEC 60068-1 | |
| relative humidity | 95 % at 55 °C | |
| operating altitude | 2000 m | |
| ambient air temperature for operation | -25…70 °C | |
| ambient air temperature for storage | -40…85 °C |
| Unit Type of Package 1 | PCE | |
|---|---|---|
| Number of Units in Package 1 | 1 | |
| Package 1 Weight | 580 g | |
| Package 1 Height | 8 cm | |
| Package 1 width | 7.2 cm | |
| Package 1 Length | 8.2 cm | |
| Unit Type of Package 2 | BB1 | |
| Number of Units in Package 2 | 4 | |
| Package 2 Weight | 2.381 kg | |
| Package 2 Height | 10 cm | |
| Package 2 width | 9 cm | |
| Package 2 Length | 33 cm | |
| Unit Type of Package 3 | S03 | |
| Number of Units in Package 3 | 24 | |
| Package 3 Weight | 14.773 kg | |
| Package 3 Height | 30 cm | |
| Package 3 width | 30 cm | |
| Package 3 Length | 40 cm |
| Sustainable offer status | Green Premium product | |
|---|---|---|
| REACh Regulation | ||
| REACh free of SVHC | Yes | |
| EU RoHS Directive | Compliant EU RoHS Declaration | |
| Toxic heavy metal free | Yes | |
| Mercury free | Yes | |
| RoHS exemption information | ||
| China RoHS Regulation | China RoHS declaration Pro-active China RoHS declaration (out of China RoHS legal scope) | |
| Environmental Disclosure | ||
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Warranty | 12 months |
|---|
Specifications for Schneider Acti 9 ACTI 9 C120N 3P 100A 10KA KURVA C
| # of Pole | 3 |
| Arus Nominal (In) | 100A |
[Deskripsi] -Kurva C (Magnetis trip antara 5 dan 10 In) -Lebar modul per kutub = 27 mm. -Dapat digunakan untuk jaringan listrik DC (Untuk 1 Pole hingga 144VDC, 2 Pole hingga 250VDC, 3 Pole hingga 375VDC, 4 Pole hingga 500VDC) -Koneksi kabel ke terminal : maksimum 35 mm2 kabel serabut atau 50 mm2 kabel tunggal. [Spesifikasi] 1. poles description : 3P 2. number of protected poles : 3 3. [In] rated current : 100 A at 30 C 4. network type : AC 5. trip unit technology : thermal-magnetic 6. curve code : C 7. breaking capacity : -6 kA Icu conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz -10 kA Icu conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz -20 kA Icu conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz -10 kA Icu conforming to EN/IEC 60947-2 - <= 250 V DC -10000 A Icn conforming to EN/IEC 60898-1 - 230...400 V AC 50/60 Hz 8. suitability for isolation : Yes conforming to IEC 60947-2 9. network frequency : 50/60 Hz 10. [Ue] rated operational voltage : -<= 375 V DC -220...240 V AC 50/60 Hz -380...415 V AC 50/60 Hz -440 V AC 50/60 Hz -230400 V AC 50/60 Hz 11. magnetic tripping limit : 5...10 x In 12. limitation class : 3 conforming to EN/IEC 60947-2 13. [Ui] rated insulation voltage : 500 V AC 50/60 Hz conforming to EN/IEC 60947-2 14. [Uimp] rated impulse withstand voltage : 6 kV conforming to EN/IEC 60947-2 15. contact position indicator : Yes 16. control type : Toggle 17. local signaling : ON/OFF indication 18. height : 81 mm 19. width : 81 mm 20. depth : 73 mm 21. product weight : 0.619 kg 22. colour : White
| range of product | C120 | |
|---|---|---|
| range | Acti 9 | |
| product name | C120 | |
| product or component type | Miniature circuit-breaker | |
| device short name | C120N | |
| device application | Distribution | |
| poles description | 3P | |
| number of protected poles | 3 | |
| [In] rated current | 100 A at 30 °C | |
| network type | AC | |
| trip unit technology | Thermal-magnetic | |
| curve code | C | |
| breaking capacity | 10000 A Icn at 230...400 V AC 50/60 Hz conforming to EN/IEC 60898-1 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at <= 375 V DC conforming to EN/IEC 60947-2 | |
| suitability for isolation | Yes conforming to IEC 60947-2 |
| network frequency | 50/60 Hz | |
|---|---|---|
| [Ue] rated operational voltage | <= 375 V DC 380...415 V AC 50/60 Hz 220...240 V AC 50/60 Hz 440 V AC 50/60 Hz 230...400 V AC 50/60 Hz | |
| magnetic tripping limit | 5...10 x In | |
| [Ics] rated service breaking capacity | 7500 A 75 % conforming to EN/IEC 60898-1 - 230...400 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 375 V DC | |
| limitation class | 3 conforming to EN/IEC 60947-2 | |
| [Ui] rated insulation voltage | 500 V AC 50/60 Hz conforming to EN/IEC 60947-2 | |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to EN/IEC 60947-2 | |
| contact position indicator | Yes | |
| control type | Toggle | |
| local signalling | ON/OFF indication | |
| mounting mode | Clip-on | |
| mounting support | 35 mm symmetrical DIN rail | |
| comb busbar and distribution block compatibility | NO | |
| 9 mm pitches | 9 | |
| height | 81 mm | |
| width | 81 mm | |
| depth | 73 mm | |
| net weight | 0.615 kg | |
| colour | White | |
| mechanical durability | 20000 cycles | |
| electrical durability | 5000 cycles conforming to IEC 60947-2 | |
| connections - terminals | Tunnel type terminals1…50 mm² rigid Tunnel type terminals1.5…35 mm² flexible | |
| wire stripping length | 15 mm | |
| tightening torque | 3.5 N.m | |
| earth-leakage protection | Separate block |
| standards | EN/IEC 60947-2 EN/IEC 60898-1 | |
|---|---|---|
| product certifications | EAC | |
| IP degree of protection | IP20 conforming to IEC 60529 | |
| pollution degree | 3 conforming to IEC 60947-2 | |
| overvoltage category | IV | |
| tropicalisation | 2 conforming to IEC 60068-1 | |
| relative humidity | 95 % at 55 °C | |
| operating altitude | 2000 m | |
| ambient air temperature for operation | -25…70 °C | |
| ambient air temperature for storage | -40…85 °C |
| Unit Type of Package 1 | PCE | |
|---|---|---|
| Number of Units in Package 1 | 1 | |
| Package 1 Weight | 580 g | |
| Package 1 Height | 8 cm | |
| Package 1 width | 7.2 cm | |
| Package 1 Length | 8.2 cm | |
| Unit Type of Package 2 | BB1 | |
| Number of Units in Package 2 | 4 | |
| Package 2 Weight | 2.381 kg | |
| Package 2 Height | 10 cm | |
| Package 2 width | 9 cm | |
| Package 2 Length | 33 cm | |
| Unit Type of Package 3 | S03 | |
| Number of Units in Package 3 | 24 | |
| Package 3 Weight | 14.773 kg | |
| Package 3 Height | 30 cm | |
| Package 3 width | 30 cm | |
| Package 3 Length | 40 cm |
| Sustainable offer status | Green Premium product | |
|---|---|---|
| REACh Regulation | ||
| REACh free of SVHC | Yes | |
| EU RoHS Directive | Compliant EU RoHS Declaration | |
| Toxic heavy metal free | Yes | |
| Mercury free | Yes | |
| RoHS exemption information | ||
| China RoHS Regulation | China RoHS declaration Pro-active China RoHS declaration (out of China RoHS legal scope) | |
| Environmental Disclosure | ||
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Warranty | 12 months |
|---|
HOT PROMO