• Sign up now and get discount up to 47%

Schneider NS1600N 4P 1600A MICROLOGIC 2.0

# of Pole : 4

Arus Nominal (In) : 1600A

Rp 63,925,332.00 Rp 31,962,665.00 31962665 IDR

Rp 63,925,332.00

Option not available

  • # of Pole
  • Arus Nominal (In)

This combination does not exist.

Add to Cart

Schneider NS1600N 4P 1600A MICROLOGIC 2.0
Terjual 0
0 (0 Rating)
Ulasan (0)

Rp 31,962,665.00
50.00 % Rp 63,925,332.00 31962665 IDR

Rp 63,925,332.00

Option not available

Atur Jumlah & Catatan
Stock Total: 2

# of Pole : 4

Arus Nominal (In) : 1600A

Spesifikasi
Main (see above)
range
ComPact
product name
ComPact NS
range of product
ComPact NS630b...1600
device short name
Compact NS1600N
product or component type
Circuit breaker
device application
Distribution
Number of poles
4P
protected poles description
4d
neutral position
Left
(In) rated current up to 65 °C
1600 A at 50 °C
[Ue] rated operational voltage
690 V AC 50/60 Hz
network type
AC
network frequency
50/60 Hz
suitability for isolation
Yes conforming to EN/IEC 60947-2
utilisation category
Category B
[Icu] rated ultimate short-circuit breaking capacity
30 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
40 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2
Performance level
N 50 kA 415 V AC
trip unit name
Micrologic 2.0
trip unit technology
Electronic
trip unit protection functions
LI
control type
Toggle
Rotary handle
Circuit breaker mounting mode
Fixed
Complementary (see above)
[Ui] rated insulation voltage
800 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage
8 kV conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity
30 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2
37 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
37 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
22 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
37 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
[Icw] rated short-time withstand current
19.2 kA 1 s conforming to IEC 60947-2
mechanical durability
10000 cycles
electrical durability
1000 cycles at 690 V In
2000 cycles at 690 V In/2
2000 cycles at 440 V In
5000 cycles at 440 V In/2
power losses
74 W
mounting support
Backplate
upside connection
Front
downside connection
Front
connection pitch
70 mm
protection type
L : for overload protection (long time)
I : for instantaneous short-circuit protection
trip unit rating
1600 A at 50 °C
Long-time pick-up adjustment type Ir (thermal protection)
Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range
0.4...1 x In
Long-time protection delay adjustment type tr
Adjustable 9 settings
[tr] long-time protection delay adjustment range
12.5…600 s at 1.5 x Ir
0.5…24 s at 6 x Ir
0.7…16.6 s at 7.2 x Ir
thermal memory
20 mn
Instantaneous protection pick-up adjustment type Ii
Adjustable
[Ii] instantaneous protection pick-up adjustment range
1.5...10 x Ir
earth-leakage protection
Without
Neutral protection settings
No protection (3d)
0.5 x Ir (3d + N/2)
1 x Ir (4d)
auxiliary contact composition
1 NO/NC
local signalling
4 LEDs (red) for fault indication
1 LED (yellow) for overload
Width (W)
280 mm
Height (H)
327 mm
Depth (D)
147 mm
net weight
18 kg
Environment (see above)
standards
EN/IEC 60947-2
product certifications
ASTA
ASEFA
pollution degree
3 conforming to IEC 60947
IP degree of protection
IP40 conforming to IEC 60529
IK degree of protection
IK07 conforming to EN 50102
ambient air temperature for operation
-25…70 °C
ambient air temperature for storage
-50…85 °C
relative humidity
0…95 %
operating altitude
0...2000 m without derating
2000 m...5000 m with derating
Packing Units (see above)
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Weight
16.966 kg
Package 1 Height
37 cm
Package 1 width
38 cm
Package 1 Length
30 cm
Offer Sustainability (see above)
Sustainable offer status
Green Premium product
REACh Regulation
EU RoHS Directive
Mercury free
Yes
RoHS exemption information
China RoHS Regulation
China RoHS declaration
Product out of China RoHS scope. Substance declaration for your information
WEEE
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Contractual warranty (see above)
Warranty
12 months

Specifications for Schneider NS1600N 4P 1600A MICROLOGIC 2.0

# of Pole 4
Arus Nominal (In) 1600A

Filter By

Product Public Price Discount Guaranteed Stock QTY Action
Rp 34,798,622.00 100.00 % 3
  • # of Pole
  • Arus Nominal (In)
  • Icu (kA)
Rp 25,570,475.00 100.00 % Out of Stock
  • # of Pole
  • Arus Nominal (In)
Rp 27,609,551.00 100.00 % 2
  • # of Pole
  • Arus Nominal (In)
  • Icu (kA)
Rp 18,966,774.00 100.00 % 10
  • # of Pole
  • Arus Nominal (In)
Rp 22,962,608.00 100.00 % 2
  • # of Pole
  • Arus Nominal (In)
  • Icu (kA)
Rp 14,528,484.00 100.00 % 2
  • # of Pole
  • Arus Nominal (In)
HOT PROMO
Main (see above)
range
ComPact
product name
ComPact NS
range of product
ComPact NS630b...1600
device short name
Compact NS1600N
product or component type
Circuit breaker
device application
Distribution
Number of poles
4P
protected poles description
4d
neutral position
Left
(In) rated current up to 65 °C
1600 A at 50 °C
[Ue] rated operational voltage
690 V AC 50/60 Hz
network type
AC
network frequency
50/60 Hz
suitability for isolation
Yes conforming to EN/IEC 60947-2
utilisation category
Category B
[Icu] rated ultimate short-circuit breaking capacity
30 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
40 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2
Performance level
N 50 kA 415 V AC
trip unit name
Micrologic 2.0
trip unit technology
Electronic
trip unit protection functions
LI
control type
Toggle
Rotary handle
Circuit breaker mounting mode
Fixed
Complementary (see above)
[Ui] rated insulation voltage
800 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage
8 kV conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity
30 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2
37 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
37 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
22 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
37 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
[Icw] rated short-time withstand current
19.2 kA 1 s conforming to IEC 60947-2
mechanical durability
10000 cycles
electrical durability
1000 cycles at 690 V In
2000 cycles at 690 V In/2
2000 cycles at 440 V In
5000 cycles at 440 V In/2
power losses
74 W
mounting support
Backplate
upside connection
Front
downside connection
Front
connection pitch
70 mm
protection type
L : for overload protection (long time)
I : for instantaneous short-circuit protection
trip unit rating
1600 A at 50 °C
Long-time pick-up adjustment type Ir (thermal protection)
Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range
0.4...1 x In
Long-time protection delay adjustment type tr
Adjustable 9 settings
[tr] long-time protection delay adjustment range
12.5…600 s at 1.5 x Ir
0.5…24 s at 6 x Ir
0.7…16.6 s at 7.2 x Ir
thermal memory
20 mn
Instantaneous protection pick-up adjustment type Ii
Adjustable
[Ii] instantaneous protection pick-up adjustment range
1.5...10 x Ir
earth-leakage protection
Without
Neutral protection settings
No protection (3d)
0.5 x Ir (3d + N/2)
1 x Ir (4d)
auxiliary contact composition
1 NO/NC
local signalling
4 LEDs (red) for fault indication
1 LED (yellow) for overload
Width (W)
280 mm
Height (H)
327 mm
Depth (D)
147 mm
net weight
18 kg
Environment (see above)
standards
EN/IEC 60947-2
product certifications
ASTA
ASEFA
pollution degree
3 conforming to IEC 60947
IP degree of protection
IP40 conforming to IEC 60529
IK degree of protection
IK07 conforming to EN 50102
ambient air temperature for operation
-25…70 °C
ambient air temperature for storage
-50…85 °C
relative humidity
0…95 %
operating altitude
0...2000 m without derating
2000 m...5000 m with derating
Packing Units (see above)
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Weight
16.966 kg
Package 1 Height
37 cm
Package 1 width
38 cm
Package 1 Length
30 cm
Offer Sustainability (see above)
Sustainable offer status
Green Premium product
REACh Regulation
EU RoHS Directive
Mercury free
Yes
RoHS exemption information
China RoHS Regulation
China RoHS declaration
Product out of China RoHS scope. Substance declaration for your information
WEEE
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Contractual warranty (see above)
Warranty
12 months