Spesifikasi
| range | TeSys | |
|---|---|---|
| product name | TeSys CAD | |
| product or component type | Control relay | |
| device short name | CAD | |
| contactor application | Control circuit |
| utilisation category | DC-13 AC-15 AC-14 | |
|---|---|---|
| pole contact composition | 5 NO | |
| [Ue] rated operational voltage | <= 690 V AC 25...400 Hz | |
| control circuit type | DC standard | |
| [Uc] control circuit voltage | 220 V DC | |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 | |
| [Ith] conventional free air thermal current | 10 A (at 60 °C) | |
| Irms rated making capacity | 140 A AC conforming to IEC 60947-5-1 250 A DC conforming to IEC 60947-5-1 | |
| [Icw] rated short-time withstand current | 100 A - 1 s 120 A - 500 ms 140 A - 100 ms | |
| associated fuse rating | 10 A gG conforming to IEC 60947-5-1 | |
| [Ui] rated insulation voltage | 600 V UL certified 600 V CSA certified 690 V conforming to IEC 60947-5-1 | |
| mounting support | Rail Plate | |
| connections - terminals | Screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end Screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end | |
| tightening torque | 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm | |
| control circuit voltage limits | 0.1...0.25 Uc (-40…70 °C):drop-out DC 0.7...1.25 Uc (-40…60 °C):operational DC 1...1.25 Uc (60…70 °C):operational DC | |
| operating time | 53...72 ms coil energisation and NO closing 16...24 ms coil de-energisation and NO opening | |
| mechanical durability | 30 Mcycles | |
| maximum operating rate | 180 cyc/mn | |
| time constant | 28 ms | |
| inrush power in W | 5.4 W (at 20 °C) | |
| hold-in power consumption in W | 5.4 W at 20 °C | |
| minimum switching voltage | 17 V | |
| minimum switching current | 5 mA | |
| non-overlap time | 1.5 ms on energisation between NC and NO contact 1.5 ms on de-energisation between NC and NO contact | |
| insulation resistance | > 10 MOhm | |
| mechanical robustness | Shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 | |
| height | 77 mm | |
| width | 45 mm | |
| depth | 93 mm | |
| net weight | 0.58 kg |
| standards | BS 4794 EN 60947-5 IEC 60947-5-1 NF C 63-140 VDE 0660 | |
|---|---|---|
| product certifications | CSA UL | |
| IP degree of protection | IP2x front face conforming to VDE 0106 | |
| protective treatment | TH conforming to IEC 60068 | |
| ambient air temperature for operation | -40…60 °C 60…70 °C with derating | |
| ambient air temperature for storage | -60…80 °C | |
| operating altitude | 0...3000 m |
| Unit Type of Package 1 | PCE | |
|---|---|---|
| Number of Units in Package 1 | 1 | |
| Package 1 Weight | 498 g | |
| Package 1 Height | 5 cm | |
| Package 1 width | 9.1 cm | |
| Package 1 Length | 11.2 cm | |
| Unit Type of Package 2 | S02 | |
| Number of Units in Package 2 | 15 | |
| Package 2 Weight | 7.772 kg | |
| Package 2 Height | 15 cm | |
| Package 2 width | 30 cm | |
| Package 2 Length | 40 cm | |
| Unit Type of Package 3 | P06 | |
| Number of Units in Package 3 | 120 | |
| Package 3 Weight | 73.82 kg | |
| Package 3 Height | 45 cm | |
| Package 3 width | 80 cm | |
| Package 3 Length | 60 cm |
| Sustainable offer status | Green Premium product | |
|---|---|---|
| REACh Regulation | ||
| EU RoHS Directive | Compliant EU RoHS Declaration | |
| Mercury free | Yes | |
| RoHS exemption information | ||
| China RoHS Regulation | China RoHS declaration Product out of China RoHS scope. Substance declaration for your information | |
| Environmental Disclosure | ||
| Circularity Profile | ||
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | |
| California proposition 65 | WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov |
| Warranty | 12 months |
|---|
| range | TeSys | |
|---|---|---|
| product name | TeSys CAD | |
| product or component type | Control relay | |
| device short name | CAD | |
| contactor application | Control circuit |
| utilisation category | DC-13 AC-15 AC-14 | |
|---|---|---|
| pole contact composition | 5 NO | |
| [Ue] rated operational voltage | <= 690 V AC 25...400 Hz | |
| control circuit type | DC standard | |
| [Uc] control circuit voltage | 220 V DC | |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 | |
| [Ith] conventional free air thermal current | 10 A (at 60 °C) | |
| Irms rated making capacity | 140 A AC conforming to IEC 60947-5-1 250 A DC conforming to IEC 60947-5-1 | |
| [Icw] rated short-time withstand current | 100 A - 1 s 120 A - 500 ms 140 A - 100 ms | |
| associated fuse rating | 10 A gG conforming to IEC 60947-5-1 | |
| [Ui] rated insulation voltage | 600 V UL certified 600 V CSA certified 690 V conforming to IEC 60947-5-1 | |
| mounting support | Rail Plate | |
| connections - terminals | Screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end Screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end | |
| tightening torque | 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm | |
| control circuit voltage limits | 0.1...0.25 Uc (-40…70 °C):drop-out DC 0.7...1.25 Uc (-40…60 °C):operational DC 1...1.25 Uc (60…70 °C):operational DC | |
| operating time | 53...72 ms coil energisation and NO closing 16...24 ms coil de-energisation and NO opening | |
| mechanical durability | 30 Mcycles | |
| maximum operating rate | 180 cyc/mn | |
| time constant | 28 ms | |
| inrush power in W | 5.4 W (at 20 °C) | |
| hold-in power consumption in W | 5.4 W at 20 °C | |
| minimum switching voltage | 17 V | |
| minimum switching current | 5 mA | |
| non-overlap time | 1.5 ms on energisation between NC and NO contact 1.5 ms on de-energisation between NC and NO contact | |
| insulation resistance | > 10 MOhm | |
| mechanical robustness | Shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 | |
| height | 77 mm | |
| width | 45 mm | |
| depth | 93 mm | |
| net weight | 0.58 kg |
| standards | BS 4794 EN 60947-5 IEC 60947-5-1 NF C 63-140 VDE 0660 | |
|---|---|---|
| product certifications | CSA UL | |
| IP degree of protection | IP2x front face conforming to VDE 0106 | |
| protective treatment | TH conforming to IEC 60068 | |
| ambient air temperature for operation | -40…60 °C 60…70 °C with derating | |
| ambient air temperature for storage | -60…80 °C | |
| operating altitude | 0...3000 m |
| Unit Type of Package 1 | PCE | |
|---|---|---|
| Number of Units in Package 1 | 1 | |
| Package 1 Weight | 498 g | |
| Package 1 Height | 5 cm | |
| Package 1 width | 9.1 cm | |
| Package 1 Length | 11.2 cm | |
| Unit Type of Package 2 | S02 | |
| Number of Units in Package 2 | 15 | |
| Package 2 Weight | 7.772 kg | |
| Package 2 Height | 15 cm | |
| Package 2 width | 30 cm | |
| Package 2 Length | 40 cm | |
| Unit Type of Package 3 | P06 | |
| Number of Units in Package 3 | 120 | |
| Package 3 Weight | 73.82 kg | |
| Package 3 Height | 45 cm | |
| Package 3 width | 80 cm | |
| Package 3 Length | 60 cm |
| Sustainable offer status | Green Premium product | |
|---|---|---|
| REACh Regulation | ||
| EU RoHS Directive | Compliant EU RoHS Declaration | |
| Mercury free | Yes | |
| RoHS exemption information | ||
| China RoHS Regulation | China RoHS declaration Product out of China RoHS scope. Substance declaration for your information | |
| Environmental Disclosure | ||
| Circularity Profile | ||
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | |
| California proposition 65 | WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov |
| Warranty | 12 months |
|---|