• Sign up now and get discount up to 47%

Schneider TeSys D contactor - 4P(2 NO + 2 NC) - AC-1 <= 440 V 60 A - 48 V AC 50/60 Hz coil

# of Pole : 4

Arus Pengenal (A) : 60A

Coil AC : 48V (E7)

Rp 3,044,607.00 Rp 1,704,979.00 1704979 IDR

Rp 3,044,607.00

Option not available

  • # of Pole
  • Arus Pengenal (A)
  • Coil AC

This combination does not exist.

Add to Cart

Schneider TeSys D contactor - 4P(2 NO + 2 NC) - AC-1 <= 440 V 60 A - 48 V AC 50/60 Hz coil
Terjual 0
0 (0 Rating)
Ulasan (0)

Rp 1,704,979.00
44.00 % Rp 3,044,607.00 1704979 IDR

Rp 3,044,607.00

Option not available

Atur Jumlah & Catatan
Stock Total: 18

# of Pole : 4

Arus Pengenal (A) : 60A

Coil AC : 48V (E7)

Spesifikasi

[Deskripsi] 1. product name : TeSys D 2. product or component type : Contactor 3. device short name : LC1D 4. contactor application : Resistive load 5. utilisation category : AC-1 6. poles description : 4P 7. power pole contact composition : 2 NO + 2 NC 8. [Ue] rated operational voltage : -Power circuit: <= 690 V AC 25...400 Hz -Power circuit: <= 300 V DC 9. [Ie] rated operational current : 60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit 10. control circuit type : AC at 50/60 Hz 11. [Uc] control circuit voltage : 48 V AC 50/60 Hz 12. auxiliary contact composition : - 13. [Uimp] rated impulse withstand voltage : 6 kV conforming to IEC 60947 14. overvoltage category : III 15. [Ith] conventional free air thermal current : 60 A (at 60 °C) for power circuit 16. Irms rated making capacity : 800 A at 440 V for power circuit conforming to IEC 60947 17. rated breaking capacity : 800 A at 440 V for power circuit conforming to IEC 60947 18. [Icw] rated short-time withstand current : -320 A 40 °C - 10 s for power circuit -720 A 40 °C - 1 s for power circuit -72 A 40 °C - 10 min for power circuit -165 A 40 °C - 1 min for power circuit 19. associated fuse rating : -80 A gG at <= 690 V coordination type 1 for power circuit -80 A gG at <= 690 V coordination type 2 for power circuit 20. average impedance : 1.5 mOhm - Ith 40 A 50 Hz for power circuit 21. [Ui] rated insulation voltage : -Power circuit: 690 V conforming to IEC 60947-4-1 -Power circuit: 600 V CSA certified -Power circuit: 600 V UL certified -Signalling circuit: 690 V conforming to IEC 60947-1 -Signalling circuit: 600 V CSA certified -Signalling circuit: 600 V UL certified 22. electrical durability : 1.4 Mcycles 60 A AC-1 at Ue <= 440 V 23. power dissipation per pole : 5.4 W AC-1 24. safety cover : With 25. mounting support : -Plate -RaiL 26. standards : -CSA C22.2 No 14 -EN 60947-4-1 -EN 60947-5-1 -IEC 60947-4-1 -IEC 60947-5-1 -UL 508 27. product certifications : -DNV -UL -LROS (Lloyds register of shipping) -CSA -CCC -GL -GOST -RINA -BV 28. coil technology : Built-in bidirectional peak limiting diode suppressor 29. control circuit voltage limits : -Drop-out: 0.1...0.25 Uc DC (at 60 °C) -Operational: 0.7...1.25 Uc DC (at 60 °C) 30. time constant : 28 ms 31. inrush power in VA : -70 VA 60 Hz cos phi 0.75 (at 20 °C) -70 VA 50 Hz cos phi 0.75 (at 20 °C) 32. hold-in power consumption in VA : -7.5 VA 60 Hz cos phi 0.3 (at 20 °C) -7 VA 50 Hz cos phi 0.3 (at 20 °C) 33. auxiliary contacts type : -type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 -type mirror contact 1 NC conforming to IEC 60947-4-1 34. signalling circuit frequency : 25...400 Hz 35. minimum switching current : 5 mA for signalling circuit 36. minimum switching voltage : 17 V for signalling circuit 37. non-overlap time : -1.5 ms on de-energisation between NC and NO contact -1.5 ms on energisation between NC and NO contact 38. insulation resistance : > 10 MOhm for signalling circuit 39. IP degree of protection : IP20 front face conforming to IEC 60529 40. protective treatment : TH conforming to IEC 60068-2-30 41. pollution degree : 3 42. ambient air temperature for operation : -5…60 °C 43. ambient air temperature for storage : -60…80 °C 44. permissible ambient air temperature around the device : -40…70 °C at Uc 45. operating altitude : 3000 m without 46. fire resistance : 850 °C conforming to IEC 60695-2-1 47. flame retardance : V1 conforming to UL 94 48. mechanical robustness : -Vibrations contactor open: 2 Gn, 5...300 Hz -Vibrations contactor closed: 4 Gn, 5...300 Hz -Shocks contactor open: 10 Gn for 11 ms -Shocks contactor closed: 15 Gn for 11 ms 49. height : 127 mm 50. width : 85 mm 51. depth : 125 mm 52. product weight : 1.44 kg

Specifications for Schneider TeSys D contactor - 4P(2 NO + 2 NC) - AC-1 <= 440 V 60 A - 48 V AC 50/60 Hz coil

General Information
# of Pole 4
Arus Pengenal (A) 60A
Uncategorized
Coil AC 48V (E7)

Filter By

Product Public Price Discount Guaranteed Stock QTY Action
Rp 2,704,407.00 100.00 % Out of Stock
  • # of Pole
  • Arus Pengenal (A)
  • Coil AC
Rp 3,968,256.00 100.00 % Out of Stock
  • # of Pole
  • Arus Pengenal (A)
  • Coil AC
Rp 2,568,674.00 100.00 % Out of Stock
  • # of Pole
  • Arus Pengenal (A)
  • Coil AC
Rp 1,619,186.00 100.00 % Out of Stock
  • # of Pole
  • Arus Pengenal (A)
  • Coil AC
Rp 0.00 0.00 % Out of Stock
  • # of Pole
  • Arus Pengenal (A)
  • Coil AC
Rp 1,704,979.00 100.00 % Out of Stock
  • # of Pole
  • Arus Pengenal (A)
  • Coil AC
HOT PROMO

[Deskripsi] 1. product name : TeSys D 2. product or component type : Contactor 3. device short name : LC1D 4. contactor application : Resistive load 5. utilisation category : AC-1 6. poles description : 4P 7. power pole contact composition : 2 NO + 2 NC 8. [Ue] rated operational voltage : -Power circuit: <= 690 V AC 25...400 Hz -Power circuit: <= 300 V DC 9. [Ie] rated operational current : 60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit 10. control circuit type : AC at 50/60 Hz 11. [Uc] control circuit voltage : 48 V AC 50/60 Hz 12. auxiliary contact composition : - 13. [Uimp] rated impulse withstand voltage : 6 kV conforming to IEC 60947 14. overvoltage category : III 15. [Ith] conventional free air thermal current : 60 A (at 60 °C) for power circuit 16. Irms rated making capacity : 800 A at 440 V for power circuit conforming to IEC 60947 17. rated breaking capacity : 800 A at 440 V for power circuit conforming to IEC 60947 18. [Icw] rated short-time withstand current : -320 A 40 °C - 10 s for power circuit -720 A 40 °C - 1 s for power circuit -72 A 40 °C - 10 min for power circuit -165 A 40 °C - 1 min for power circuit 19. associated fuse rating : -80 A gG at <= 690 V coordination type 1 for power circuit -80 A gG at <= 690 V coordination type 2 for power circuit 20. average impedance : 1.5 mOhm - Ith 40 A 50 Hz for power circuit 21. [Ui] rated insulation voltage : -Power circuit: 690 V conforming to IEC 60947-4-1 -Power circuit: 600 V CSA certified -Power circuit: 600 V UL certified -Signalling circuit: 690 V conforming to IEC 60947-1 -Signalling circuit: 600 V CSA certified -Signalling circuit: 600 V UL certified 22. electrical durability : 1.4 Mcycles 60 A AC-1 at Ue <= 440 V 23. power dissipation per pole : 5.4 W AC-1 24. safety cover : With 25. mounting support : -Plate -RaiL 26. standards : -CSA C22.2 No 14 -EN 60947-4-1 -EN 60947-5-1 -IEC 60947-4-1 -IEC 60947-5-1 -UL 508 27. product certifications : -DNV -UL -LROS (Lloyds register of shipping) -CSA -CCC -GL -GOST -RINA -BV 28. coil technology : Built-in bidirectional peak limiting diode suppressor 29. control circuit voltage limits : -Drop-out: 0.1...0.25 Uc DC (at 60 °C) -Operational: 0.7...1.25 Uc DC (at 60 °C) 30. time constant : 28 ms 31. inrush power in VA : -70 VA 60 Hz cos phi 0.75 (at 20 °C) -70 VA 50 Hz cos phi 0.75 (at 20 °C) 32. hold-in power consumption in VA : -7.5 VA 60 Hz cos phi 0.3 (at 20 °C) -7 VA 50 Hz cos phi 0.3 (at 20 °C) 33. auxiliary contacts type : -type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 -type mirror contact 1 NC conforming to IEC 60947-4-1 34. signalling circuit frequency : 25...400 Hz 35. minimum switching current : 5 mA for signalling circuit 36. minimum switching voltage : 17 V for signalling circuit 37. non-overlap time : -1.5 ms on de-energisation between NC and NO contact -1.5 ms on energisation between NC and NO contact 38. insulation resistance : > 10 MOhm for signalling circuit 39. IP degree of protection : IP20 front face conforming to IEC 60529 40. protective treatment : TH conforming to IEC 60068-2-30 41. pollution degree : 3 42. ambient air temperature for operation : -5…60 °C 43. ambient air temperature for storage : -60…80 °C 44. permissible ambient air temperature around the device : -40…70 °C at Uc 45. operating altitude : 3000 m without 46. fire resistance : 850 °C conforming to IEC 60695-2-1 47. flame retardance : V1 conforming to UL 94 48. mechanical robustness : -Vibrations contactor open: 2 Gn, 5...300 Hz -Vibrations contactor closed: 4 Gn, 5...300 Hz -Shocks contactor open: 10 Gn for 11 ms -Shocks contactor closed: 15 Gn for 11 ms 49. height : 127 mm 50. width : 85 mm 51. depth : 125 mm 52. product weight : 1.44 kg