Schneider TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A - 110 V AC 50/60 Hz coil
# of Pole : 3
Arus Pengenal (A) : 50A
Coil AC : 110V (F7)
Rp 1,351,563.00
44.00 %
Rp 2,413,506.00
Rp 2,413,506.00
Option not available
[Deskripsi] 1. product name : TeSys D 2. product or component type : Contactor 3. device short name : LC1D 4. contactor application : -Motor Control -Resistive load 5. utilisation category : -AC-4 -AC-1 -AC-3 6. poles description : 3P 7. power pole contact composition : 3 NO 8. [Ue] rated operational voltage : -Power circuit: <= 690 V AC 25...400 Hz -Power circuit: <= 300 V DC 9. [Ie] rated operational current : -50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit -80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit 10.motor power kW : -15 kW at 220...230 V AC 50/60 Hz (AC-3) -22 kW at 380...400 V AC 50/60 Hz (AC-3) -30 kW at 500 V AC 50/60 Hz (AC-3) -33 kW at 660...690 V AC 50/60 Hz (AC-3) -25 kW at 415 V AC 50/60 Hz (AC-3) -30 kW at 440 V AC 50/60 Hz (AC-3) -11 kW at 400 V AC 50/60 Hz (AC-4) 11. motor power HP (UL / CSA) : -3 hp at 115 V AC 50/60 Hz for 1 phase motors -7.5 hp at 230/240 V AC 50/60 Hz for 1 phase motors -15 hp at 200/208 V AC 50/60 Hz for 3 phases motors -15 hp at 230/240 V AC 50/60 Hz for 3 phases motors -40 hp at 460/480 V AC 50/60 Hz for 3 phases motors -40 hp at 575/600 V AC 50/60 Hz for 3 phases motors 12. control circuit type : AC at 50/60 Hz 13. [Uc] control circuit voltage : 110 V AC 50/60 Hz 14. auxiliary contact composition : 1 NO + 1 NC 15. [Uimp] rated impulse withstand voltage : 6 kV conforming to IEC 60947 16. overvoltage category : III 17. [Ith] conventional free air thermal current : -25 A (at 60 °C) for power circuit -10 A (at 60 °C) for signalling circuit 18. Irms rated making capacity : -250 A at 440 V for power circuit conforming to IEC 60947 -140 A AC for signalling circuit conforming to IEC 60947-5-1 -250 A DC for signalling circuit conforming to IEC 60947-5-1 19. rated breaking capacity : 250 A at 440 V for power circuit conforming to IEC 60947 20. [Icw] rated short-time withstand current : -105 A 40 °C - 10 s for power circuit -210 A 40 °C - 1 s for power circuit -30 A 40 °C - 10 min for power circuit -61 A 40 °C - 1 min for power circuit -100 A - 1 s for signalling circuit -120 A - 500 ms for signalling circuit -140 A - 100 ms for signalling circuit 21. associated fuse rating : -10 A gG for signalling circuit conforming to IEC 60947-5-1 -25 A gG at <= 690 V coordination type 1 for power circuit -20 A gG at <= 690 V coordination type 2 for power circuit 22. average impedance : 2.5 mOhm - Ith 25 A 50 Hz for power circuit 23. [Ui] rated insulation voltage : -Power circuit: 690 V conforming to IEC 60947-4-1 -Power circuit: 600 V CSA certified -Power circuit: 600 V UL certified -Signalling circuit: 690 V conforming to IEC 60947-1 -Signalling circuit: 600 V CSA certified -Signalling circuit: 600 V UL certified 24. electrical durability : -0.6 Mcycles 25 A AC-1 at Ue <= 440 V -2 Mcycles 9 A AC-3 at Ue <= 440 V 25. power dissipation per pole : -1.56 W AC-1 -0.2 W AC-3 26. safety cover : With 27. mounting support : -Plate -RaiL 28. standards : -CSA C22.2 No 14 -EN 60947-4-1 -EN 60947-5-1 -IEC 60947-4-1 -IEC 60947-5-1 -UL 508 29. product certifications : -DNV -UL -LROS (Lloyds register of shipping) -CSA -CCC -GL -GOST -RINA -BV 30. coil technology : Built-in bidirectional peak limiting diode suppressor 31. control circuit voltage limits : -Drop-out: 0.1...0.25 Uc DC (at 60 °C) -Operational: 0.7...1.25 Uc DC (at 60 °C) 32. time constant : 28 ms 33. inrush power in W : 5.4 W (at 20 °C) 34. hold-in power consumption in W : 5.4 W at 20 °C 35. auxiliary contacts type : -type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 -type mirror contact 1 NC conforming to IEC 60947-4-1 36. signalling circuit frequency : 25...400 Hz 37. minimum switching current : 5 mA for signalling circuit 38. minimum switching voltage : 17 V for signalling circuit 39. non-overlap time : -1.5 ms on de-energisation between NC and NO contact -1.5 ms on energisation between NC and NO contact 40. insulation resistance : > 10 MOhm for signalling circuit 41. height : 122 mm 42. width : 55 mm 43. depth : 120 mm 44. product weight : 0.855 kg
range | TeSys | |
---|---|---|
product name | TeSys D | |
product or component type | Contactor | |
device short name | LC1D | |
contactor application | Motor control Resistive load | |
utilisation category | AC-1 AC-4 AC-3 | |
poles description | 3P | |
power pole contact composition | 3 NO | |
[Ue] rated operational voltage | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | |
[Ie] rated operational current | 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit | |
motor power kW | 15 kW at 220...230 V AC 50/60 Hz (AC-3) 22 kW at 380...400 V AC 50/60 Hz (AC-3) 30 kW at 500 V AC 50/60 Hz (AC-3) 33 kW at 660...690 V AC 50/60 Hz (AC-3) 25 kW at 415 V AC 50/60 Hz (AC-3) 30 kW at 440 V AC 50/60 Hz (AC-3) 11 kW at 400 V AC 50/60 Hz (AC-4) | |
motor power HP (UL / CSA) | 3 hp at 115 V AC 50/60 Hz for 1 phase motors 7.5 hp at 230/240 V AC 50/60 Hz for 1 phase motors 15 hp at 200/208 V AC 50/60 Hz for 3 phases motors 15 hp at 230/240 V AC 50/60 Hz for 3 phases motors 40 hp at 460/480 V AC 50/60 Hz for 3 phases motors 40 hp at 575/600 V AC 50/60 Hz for 3 phases motors | |
control circuit type | AC at 50/60 Hz | |
[Uc] control circuit voltage | 110 V AC 50/60 Hz | |
auxiliary contact composition | 1 NO + 1 NC | |
[Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 | |
overvoltage category | III | |
[Ith] conventional free air thermal current | 10 A (at 60 °C) for signalling circuit 80 A (at 60 °C) for power circuit | |
Irms rated making capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 900 A at 440 V for power circuit conforming to IEC 60947 | |
rated breaking capacity | 900 A at 440 V for power circuit conforming to IEC 60947 | |
[Icw] rated short-time withstand current | 400 A 40 °C - 10 s for power circuit 810 A 40 °C - 1 s for power circuit 84 A 40 °C - 10 min for power circuit 208 A 40 °C - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | |
associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1 100 A gG at <= 690 V coordination type 1 for power circuit 100 A gG at <= 690 V coordination type 2 for power circuit | |
average impedance | 1.5 mOhm - Ith 80 A 50 Hz for power circuit | |
[Ui] rated insulation voltage | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 | |
electrical durability | 1.45 Mcycles 50 A AC-3 at Ue <= 440 V 1.1 Mcycles 80 A AC-1 at Ue <= 440 V | |
power dissipation per pole | 3.7 W AC-3 9.6 W AC-1 | |
Front cover | With | |
mounting support | Rail Plate | |
standards | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | |
product certifications | CCC GOST UL LROS (Lloyds register of shipping) CSA DNV BV GL RINA | |
connections - terminals | Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end Power circuit: screw connection 1 cable(s) 1…35 mm²flexible without cable end Power circuit: screw connection 2 cable(s) 1…25 mm²flexible without cable end Power circuit: screw connection 1 cable(s) 1…35 mm²flexible with cable end Power circuit: screw connection 2 cable(s) 1…25 mm²flexible with cable end Power circuit: screw connection 1 cable(s) 1…35 mm²solid without cable end Power circuit: screw connection 2 cable(s) 1…25 mm²solid without cable end | |
tightening torque | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25…35 mm² hexagonal screw head 4 mm Power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1…25 mm² hexagonal screw head 4 mm | |
operating time | 4...19 ms opening 12...26 ms closing | |
safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | |
mechanical durability | 6 Mcycles | |
maximum operating rate | 3600 cyc/h 60 °C |
coil technology | Without built-in suppressor module | |
---|---|---|
inrush power in VA | 140 VA 60 Hz cos phi 0.75 (at 20 °C) 160 VA 50 Hz cos phi 0.75 (at 20 °C) | |
hold-in power consumption in VA | 13 VA 60 Hz cos phi 0.3 (at 20 °C) 15 VA 50 Hz cos phi 0.3 (at 20 °C) | |
heat dissipation | 4…5 W at 50/60 Hz | |
auxiliary contacts type | type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1 | |
signalling circuit frequency | 25...400 Hz | |
minimum switching current | 5 mA for signalling circuit | |
minimum switching voltage | 17 V for signalling circuit | |
non-overlap time | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | |
insulation resistance | > 10 MOhm for signalling circuit |
IP degree of protection | IP20 front face conforming to IEC 60529 | |
---|---|---|
protective treatment | TH conforming to IEC 60068-2-30 | |
pollution degree | 3 | |
ambient air temperature for storage | -60…80 °C | |
operating altitude | 3000 m without derating | |
fire resistance | 850 °C conforming to IEC 60695-2-1 | |
flame retardance | V1 conforming to UL 94 | |
mechanical robustness | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 10 Gn for 11 ms | |
height | 122 mm | |
width | 55 mm | |
depth | 120 mm | |
net weight | 0.855 kg |
Unit Type of Package 1 | PCE | |
---|---|---|
Number of Units in Package 1 | 1 | |
Package 1 Weight | 946 g | |
Package 1 Height | 6.2 cm | |
Package 1 width | 13.5 cm | |
Package 1 Length | 15.5 cm | |
Unit Type of Package 2 | P06 | |
Number of Units in Package 2 | 160 | |
Package 2 Weight | 167.14 kg | |
Package 2 Height | 77 cm | |
Package 2 width | 80 cm | |
Package 2 Length | 60 cm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
REACh free of SVHC | Yes | |
EU RoHS Directive | Compliant EU RoHS Declaration | |
Toxic heavy metal free | Yes | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | China RoHS declaration Pro-active China RoHS declaration (out of China RoHS legal scope) | |
Environmental Disclosure | ||
Circularity Profile | ||
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | |
PVC free | Yes | |
California proposition 65 | WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov |
Warranty | 12 months |
---|
Specifications for Schneider TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A - 110 V AC 50/60 Hz coil
General Information | |
---|---|
# of Pole | 3 |
Arus Pengenal (A) | 50A |
Uncategorized | |
Coil AC | 110V (F7) |
[Deskripsi] 1. product name : TeSys D 2. product or component type : Contactor 3. device short name : LC1D 4. contactor application : -Motor Control -Resistive load 5. utilisation category : -AC-4 -AC-1 -AC-3 6. poles description : 3P 7. power pole contact composition : 3 NO 8. [Ue] rated operational voltage : -Power circuit: <= 690 V AC 25...400 Hz -Power circuit: <= 300 V DC 9. [Ie] rated operational current : -50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit -80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit 10.motor power kW : -15 kW at 220...230 V AC 50/60 Hz (AC-3) -22 kW at 380...400 V AC 50/60 Hz (AC-3) -30 kW at 500 V AC 50/60 Hz (AC-3) -33 kW at 660...690 V AC 50/60 Hz (AC-3) -25 kW at 415 V AC 50/60 Hz (AC-3) -30 kW at 440 V AC 50/60 Hz (AC-3) -11 kW at 400 V AC 50/60 Hz (AC-4) 11. motor power HP (UL / CSA) : -3 hp at 115 V AC 50/60 Hz for 1 phase motors -7.5 hp at 230/240 V AC 50/60 Hz for 1 phase motors -15 hp at 200/208 V AC 50/60 Hz for 3 phases motors -15 hp at 230/240 V AC 50/60 Hz for 3 phases motors -40 hp at 460/480 V AC 50/60 Hz for 3 phases motors -40 hp at 575/600 V AC 50/60 Hz for 3 phases motors 12. control circuit type : AC at 50/60 Hz 13. [Uc] control circuit voltage : 110 V AC 50/60 Hz 14. auxiliary contact composition : 1 NO + 1 NC 15. [Uimp] rated impulse withstand voltage : 6 kV conforming to IEC 60947 16. overvoltage category : III 17. [Ith] conventional free air thermal current : -25 A (at 60 °C) for power circuit -10 A (at 60 °C) for signalling circuit 18. Irms rated making capacity : -250 A at 440 V for power circuit conforming to IEC 60947 -140 A AC for signalling circuit conforming to IEC 60947-5-1 -250 A DC for signalling circuit conforming to IEC 60947-5-1 19. rated breaking capacity : 250 A at 440 V for power circuit conforming to IEC 60947 20. [Icw] rated short-time withstand current : -105 A 40 °C - 10 s for power circuit -210 A 40 °C - 1 s for power circuit -30 A 40 °C - 10 min for power circuit -61 A 40 °C - 1 min for power circuit -100 A - 1 s for signalling circuit -120 A - 500 ms for signalling circuit -140 A - 100 ms for signalling circuit 21. associated fuse rating : -10 A gG for signalling circuit conforming to IEC 60947-5-1 -25 A gG at <= 690 V coordination type 1 for power circuit -20 A gG at <= 690 V coordination type 2 for power circuit 22. average impedance : 2.5 mOhm - Ith 25 A 50 Hz for power circuit 23. [Ui] rated insulation voltage : -Power circuit: 690 V conforming to IEC 60947-4-1 -Power circuit: 600 V CSA certified -Power circuit: 600 V UL certified -Signalling circuit: 690 V conforming to IEC 60947-1 -Signalling circuit: 600 V CSA certified -Signalling circuit: 600 V UL certified 24. electrical durability : -0.6 Mcycles 25 A AC-1 at Ue <= 440 V -2 Mcycles 9 A AC-3 at Ue <= 440 V 25. power dissipation per pole : -1.56 W AC-1 -0.2 W AC-3 26. safety cover : With 27. mounting support : -Plate -RaiL 28. standards : -CSA C22.2 No 14 -EN 60947-4-1 -EN 60947-5-1 -IEC 60947-4-1 -IEC 60947-5-1 -UL 508 29. product certifications : -DNV -UL -LROS (Lloyds register of shipping) -CSA -CCC -GL -GOST -RINA -BV 30. coil technology : Built-in bidirectional peak limiting diode suppressor 31. control circuit voltage limits : -Drop-out: 0.1...0.25 Uc DC (at 60 °C) -Operational: 0.7...1.25 Uc DC (at 60 °C) 32. time constant : 28 ms 33. inrush power in W : 5.4 W (at 20 °C) 34. hold-in power consumption in W : 5.4 W at 20 °C 35. auxiliary contacts type : -type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 -type mirror contact 1 NC conforming to IEC 60947-4-1 36. signalling circuit frequency : 25...400 Hz 37. minimum switching current : 5 mA for signalling circuit 38. minimum switching voltage : 17 V for signalling circuit 39. non-overlap time : -1.5 ms on de-energisation between NC and NO contact -1.5 ms on energisation between NC and NO contact 40. insulation resistance : > 10 MOhm for signalling circuit 41. height : 122 mm 42. width : 55 mm 43. depth : 120 mm 44. product weight : 0.855 kg
range | TeSys | |
---|---|---|
product name | TeSys D | |
product or component type | Contactor | |
device short name | LC1D | |
contactor application | Motor control Resistive load | |
utilisation category | AC-1 AC-4 AC-3 | |
poles description | 3P | |
power pole contact composition | 3 NO | |
[Ue] rated operational voltage | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | |
[Ie] rated operational current | 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit | |
motor power kW | 15 kW at 220...230 V AC 50/60 Hz (AC-3) 22 kW at 380...400 V AC 50/60 Hz (AC-3) 30 kW at 500 V AC 50/60 Hz (AC-3) 33 kW at 660...690 V AC 50/60 Hz (AC-3) 25 kW at 415 V AC 50/60 Hz (AC-3) 30 kW at 440 V AC 50/60 Hz (AC-3) 11 kW at 400 V AC 50/60 Hz (AC-4) | |
motor power HP (UL / CSA) | 3 hp at 115 V AC 50/60 Hz for 1 phase motors 7.5 hp at 230/240 V AC 50/60 Hz for 1 phase motors 15 hp at 200/208 V AC 50/60 Hz for 3 phases motors 15 hp at 230/240 V AC 50/60 Hz for 3 phases motors 40 hp at 460/480 V AC 50/60 Hz for 3 phases motors 40 hp at 575/600 V AC 50/60 Hz for 3 phases motors | |
control circuit type | AC at 50/60 Hz | |
[Uc] control circuit voltage | 110 V AC 50/60 Hz | |
auxiliary contact composition | 1 NO + 1 NC | |
[Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 | |
overvoltage category | III | |
[Ith] conventional free air thermal current | 10 A (at 60 °C) for signalling circuit 80 A (at 60 °C) for power circuit | |
Irms rated making capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 900 A at 440 V for power circuit conforming to IEC 60947 | |
rated breaking capacity | 900 A at 440 V for power circuit conforming to IEC 60947 | |
[Icw] rated short-time withstand current | 400 A 40 °C - 10 s for power circuit 810 A 40 °C - 1 s for power circuit 84 A 40 °C - 10 min for power circuit 208 A 40 °C - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | |
associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1 100 A gG at <= 690 V coordination type 1 for power circuit 100 A gG at <= 690 V coordination type 2 for power circuit | |
average impedance | 1.5 mOhm - Ith 80 A 50 Hz for power circuit | |
[Ui] rated insulation voltage | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 | |
electrical durability | 1.45 Mcycles 50 A AC-3 at Ue <= 440 V 1.1 Mcycles 80 A AC-1 at Ue <= 440 V | |
power dissipation per pole | 3.7 W AC-3 9.6 W AC-1 | |
Front cover | With | |
mounting support | Rail Plate | |
standards | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | |
product certifications | CCC GOST UL LROS (Lloyds register of shipping) CSA DNV BV GL RINA | |
connections - terminals | Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end Power circuit: screw connection 1 cable(s) 1…35 mm²flexible without cable end Power circuit: screw connection 2 cable(s) 1…25 mm²flexible without cable end Power circuit: screw connection 1 cable(s) 1…35 mm²flexible with cable end Power circuit: screw connection 2 cable(s) 1…25 mm²flexible with cable end Power circuit: screw connection 1 cable(s) 1…35 mm²solid without cable end Power circuit: screw connection 2 cable(s) 1…25 mm²solid without cable end | |
tightening torque | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25…35 mm² hexagonal screw head 4 mm Power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1…25 mm² hexagonal screw head 4 mm | |
operating time | 4...19 ms opening 12...26 ms closing | |
safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | |
mechanical durability | 6 Mcycles | |
maximum operating rate | 3600 cyc/h 60 °C |
coil technology | Without built-in suppressor module | |
---|---|---|
inrush power in VA | 140 VA 60 Hz cos phi 0.75 (at 20 °C) 160 VA 50 Hz cos phi 0.75 (at 20 °C) | |
hold-in power consumption in VA | 13 VA 60 Hz cos phi 0.3 (at 20 °C) 15 VA 50 Hz cos phi 0.3 (at 20 °C) | |
heat dissipation | 4…5 W at 50/60 Hz | |
auxiliary contacts type | type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1 | |
signalling circuit frequency | 25...400 Hz | |
minimum switching current | 5 mA for signalling circuit | |
minimum switching voltage | 17 V for signalling circuit | |
non-overlap time | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | |
insulation resistance | > 10 MOhm for signalling circuit |
IP degree of protection | IP20 front face conforming to IEC 60529 | |
---|---|---|
protective treatment | TH conforming to IEC 60068-2-30 | |
pollution degree | 3 | |
ambient air temperature for storage | -60…80 °C | |
operating altitude | 3000 m without derating | |
fire resistance | 850 °C conforming to IEC 60695-2-1 | |
flame retardance | V1 conforming to UL 94 | |
mechanical robustness | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 10 Gn for 11 ms | |
height | 122 mm | |
width | 55 mm | |
depth | 120 mm | |
net weight | 0.855 kg |
Unit Type of Package 1 | PCE | |
---|---|---|
Number of Units in Package 1 | 1 | |
Package 1 Weight | 946 g | |
Package 1 Height | 6.2 cm | |
Package 1 width | 13.5 cm | |
Package 1 Length | 15.5 cm | |
Unit Type of Package 2 | P06 | |
Number of Units in Package 2 | 160 | |
Package 2 Weight | 167.14 kg | |
Package 2 Height | 77 cm | |
Package 2 width | 80 cm | |
Package 2 Length | 60 cm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
REACh free of SVHC | Yes | |
EU RoHS Directive | Compliant EU RoHS Declaration | |
Toxic heavy metal free | Yes | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | China RoHS declaration Pro-active China RoHS declaration (out of China RoHS legal scope) | |
Environmental Disclosure | ||
Circularity Profile | ||
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | |
PVC free | Yes | |
California proposition 65 | WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov |
Warranty | 12 months |
---|