Spesifikasi
range of product | TeSys D | |
---|---|---|
range | TeSys | |
product or component type | Contactor | |
device short name | LC1D | |
contactor application | Motor control Resistive load | |
utilisation category | AC-1 AC-2 AC-4 AC-3 | |
control circuit type | DC standard | |
poles description | 3P | |
pole contact composition | 3 NO | |
[Ie] rated operational current | 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit | |
motor power kW | 22 kW at 380...400 V AC 50 Hz (AC-3) 25 kW at 415 V AC 50 Hz (AC-3) 30 kW at 440 V AC 50 Hz (AC-3) 30 kW at 500 V AC 50 Hz (AC-3) 33 kW at 660...690 V AC 50 Hz (AC-3) 15 kW at 220...230 V AC 50 Hz (AC-3) 11 kW at 400 V AC 50 Hz (AC-4) 30 kW at 1000 V AC 50 Hz (AC-3) |
coil technology | Built-in bidirectional peak limiting diode suppressor | |
---|---|---|
Front cover | With | |
motor power hp | 3 hp at 115 V AC 60 Hz for 1 phase motors 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors 15 hp at 200/208 V AC 60 Hz for 3 phases motors 15 hp at 230/240 V AC 60 Hz for 3 phases motors 40 hp at 460/480 V AC 60 Hz for 3 phases motors 40 hp at 575/600 V AC 60 Hz for 3 phases motors | |
auxiliary contacts type | type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1 | |
auxiliary contact composition | 1 NO + 1 NC | |
[Uc] control circuit voltage | 24 V DC | |
control circuit voltage limits | 0.1...0.3 Uc (-40…70 °C):drop-out DC 0.75...1.25 Uc (-40…60 °C):operational DC 1...1.25 Uc (60…70 °C):operational DC | |
time constant | 34 ms | |
[Ui] rated insulation voltage | Control circuit: 600 V CSA certified Control circuit: 600 V UL certified Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Control circuit: 690 V conforming to IEC 60947-1 Power circuit: 690 V conforming to IEC 60947-1 Power circuit: 1000 V conforming to IEC 60947-4-1 | |
[Uimp] rated impulse withstand voltage | 8 kV conforming to IEC 60947 | |
overvoltage category | III | |
mounting support | Rail Plate | |
flame retardance | V1 conforming to UL 94 | |
connections - terminals | Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²rigid Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²rigid Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Power circuit: screw terminals 1 cable(s) 2.5…25 mm²rigid Power circuit: screw terminals 2 cable(s) 2.5…16 mm²rigid Power circuit: screw terminals 1 cable(s) 2.5…25 mm²flexible without cable end Power circuit: screw terminals 2 cable(s) 2.5…16 mm²flexible without cable end Power circuit: screw terminals 1 cable(s) 2.5…25 mm²flexible with cable end Power circuit: screw terminals 2 cable(s) 2.5…10 mm²flexible with cable end | |
tightening torque | Control circuit: 1.7 N.m - on screw clamp terminal - with screwdriver flat Ø 6 mm Control circuit: 1.7 N.m - on screw clamp terminal - with screwdriver Philips No 2 Power circuit: 5 N.m - on screw terminal - with screwdriver flat Ø 6 to Ø 8 mm | |
[Ue] rated operational voltage | Power circuit: <= 690 V AC 25...400 Hz | |
[Ith] conventional free air thermal current | 10 A (at 60 °C) for control circuit 80 A (at 60 °C) for power circuit | |
Irms rated making capacity | 250 A DC for control circuit conforming to IEC 60947-5-1 900 A at 440 V for power circuit conforming to IEC 60947 | |
rated breaking capacity | 900 A at 440 V for power circuit conforming to IEC 60947 | |
associated fuse rating | 10 A gG for control circuit conforming to IEC 60947-5-1 100 A gG at <= 690 V coordination type 1 for power circuit 100 A gG at <= 690 V coordination type 2 for power circuit | |
power dissipation per pole | 3.7 W AC-3 9.6 W AC-1 | |
inrush power in W | 19 W (at 20 °C) | |
hold-in power consumption in W | 7.4 W at 20 °C | |
operating time | 20 ms opening 50 ms closing | |
safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | |
mechanical durability | 10000000 cycles | |
maximum operating rate | 3600 cyc/h 60 °C | |
minimum switching current | 5 mA for control circuit | |
minimum switching voltage | 17 V for control circuit | |
non-overlap time | 1.5 ms on de-energisation between NC and NO contacts 1.5 ms on energisation between NC and NO contacts | |
insulation resistance | > 10 MOhm for control circuit | |
rated operational power in W | 14 W at 24 V DC-13 - electrical durability: 10000000 cycles - for control circuit 48 W at 24 V DC-13 - electrical durability: 3000000 cycles - for control circuit 96 W at 24 V DC-13 - electrical durability: 1000000 cycles - for control circuit | |
height | 127 mm | |
width | 85 mm | |
depth | 176 mm | |
net weight | 2.185 kg |
standards | UL 508 CSA C22.2 No 14 IEC 60947-5-1 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 | |
---|---|---|
product certifications | LROS (Lloyds register of shipping) CSA DNV RINA BV CCC UL GOST GL | |
IP degree of protection | IP2x conforming to IEC 60529 IP2x conforming to VDE 0106 | |
ambient air temperature for operation | -40…60 °C 60…70 °C with derating | |
ambient air temperature for storage | -60…80 °C | |
operating altitude | 0...3000 m | |
fire resistance | 850 °C conforming to IEC 60695-2-1 | |
shock resistance | 10 gn contactor opened 15 gn contactor closed | |
vibration resistance | 2 gn 5…300 Hz contactor opened 4 gn 5…300 Hz contactor closed |
Unit Type of Package 1 | PCE | |
---|---|---|
Number of Units in Package 1 | 1 | |
Package 1 Weight | 2.169 kg | |
Package 1 Height | 9 cm | |
Package 1 width | 14 cm | |
Package 1 Length | 18.5 cm | |
Unit Type of Package 2 | S02 | |
Number of Units in Package 2 | 2 | |
Package 2 Weight | 4.829 kg | |
Package 2 Height | 15 cm | |
Package 2 width | 30 cm | |
Package 2 Length | 40 cm | |
Unit Type of Package 3 | P06 | |
Number of Units in Package 3 | 40 | |
Package 3 Weight | 99.924 kg | |
Package 3 Height | 77 cm | |
Package 3 width | 80 cm | |
Package 3 Length | 60 cm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
REACh free of SVHC | Yes | |
EU RoHS Directive | Compliant EU RoHS Declaration | |
Toxic heavy metal free | Yes | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | China RoHS declaration Pro-active China RoHS declaration (out of China RoHS legal scope) | |
Environmental Disclosure | ||
Circularity Profile | ||
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | |
PVC free | Yes | |
California proposition 65 | WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov |
Warranty | 12 months |
---|
Specifications for Schneider CONTACTOR 600VAC 50AMP IEC +OPTIONS
General Information | |
---|---|
Arus Pengenal (A) | 50A |
Uncategorized | |
Coil DC | 24V (BD) |
Filter By
range of product | TeSys D | |
---|---|---|
range | TeSys | |
product or component type | Contactor | |
device short name | LC1D | |
contactor application | Motor control Resistive load | |
utilisation category | AC-1 AC-2 AC-4 AC-3 | |
control circuit type | DC standard | |
poles description | 3P | |
pole contact composition | 3 NO | |
[Ie] rated operational current | 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit | |
motor power kW | 22 kW at 380...400 V AC 50 Hz (AC-3) 25 kW at 415 V AC 50 Hz (AC-3) 30 kW at 440 V AC 50 Hz (AC-3) 30 kW at 500 V AC 50 Hz (AC-3) 33 kW at 660...690 V AC 50 Hz (AC-3) 15 kW at 220...230 V AC 50 Hz (AC-3) 11 kW at 400 V AC 50 Hz (AC-4) 30 kW at 1000 V AC 50 Hz (AC-3) |
coil technology | Built-in bidirectional peak limiting diode suppressor | |
---|---|---|
Front cover | With | |
motor power hp | 3 hp at 115 V AC 60 Hz for 1 phase motors 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors 15 hp at 200/208 V AC 60 Hz for 3 phases motors 15 hp at 230/240 V AC 60 Hz for 3 phases motors 40 hp at 460/480 V AC 60 Hz for 3 phases motors 40 hp at 575/600 V AC 60 Hz for 3 phases motors | |
auxiliary contacts type | type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1 | |
auxiliary contact composition | 1 NO + 1 NC | |
[Uc] control circuit voltage | 24 V DC | |
control circuit voltage limits | 0.1...0.3 Uc (-40…70 °C):drop-out DC 0.75...1.25 Uc (-40…60 °C):operational DC 1...1.25 Uc (60…70 °C):operational DC | |
time constant | 34 ms | |
[Ui] rated insulation voltage | Control circuit: 600 V CSA certified Control circuit: 600 V UL certified Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Control circuit: 690 V conforming to IEC 60947-1 Power circuit: 690 V conforming to IEC 60947-1 Power circuit: 1000 V conforming to IEC 60947-4-1 | |
[Uimp] rated impulse withstand voltage | 8 kV conforming to IEC 60947 | |
overvoltage category | III | |
mounting support | Rail Plate | |
flame retardance | V1 conforming to UL 94 | |
connections - terminals | Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²rigid Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²rigid Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Power circuit: screw terminals 1 cable(s) 2.5…25 mm²rigid Power circuit: screw terminals 2 cable(s) 2.5…16 mm²rigid Power circuit: screw terminals 1 cable(s) 2.5…25 mm²flexible without cable end Power circuit: screw terminals 2 cable(s) 2.5…16 mm²flexible without cable end Power circuit: screw terminals 1 cable(s) 2.5…25 mm²flexible with cable end Power circuit: screw terminals 2 cable(s) 2.5…10 mm²flexible with cable end | |
tightening torque | Control circuit: 1.7 N.m - on screw clamp terminal - with screwdriver flat Ø 6 mm Control circuit: 1.7 N.m - on screw clamp terminal - with screwdriver Philips No 2 Power circuit: 5 N.m - on screw terminal - with screwdriver flat Ø 6 to Ø 8 mm | |
[Ue] rated operational voltage | Power circuit: <= 690 V AC 25...400 Hz | |
[Ith] conventional free air thermal current | 10 A (at 60 °C) for control circuit 80 A (at 60 °C) for power circuit | |
Irms rated making capacity | 250 A DC for control circuit conforming to IEC 60947-5-1 900 A at 440 V for power circuit conforming to IEC 60947 | |
rated breaking capacity | 900 A at 440 V for power circuit conforming to IEC 60947 | |
associated fuse rating | 10 A gG for control circuit conforming to IEC 60947-5-1 100 A gG at <= 690 V coordination type 1 for power circuit 100 A gG at <= 690 V coordination type 2 for power circuit | |
power dissipation per pole | 3.7 W AC-3 9.6 W AC-1 | |
inrush power in W | 19 W (at 20 °C) | |
hold-in power consumption in W | 7.4 W at 20 °C | |
operating time | 20 ms opening 50 ms closing | |
safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | |
mechanical durability | 10000000 cycles | |
maximum operating rate | 3600 cyc/h 60 °C | |
minimum switching current | 5 mA for control circuit | |
minimum switching voltage | 17 V for control circuit | |
non-overlap time | 1.5 ms on de-energisation between NC and NO contacts 1.5 ms on energisation between NC and NO contacts | |
insulation resistance | > 10 MOhm for control circuit | |
rated operational power in W | 14 W at 24 V DC-13 - electrical durability: 10000000 cycles - for control circuit 48 W at 24 V DC-13 - electrical durability: 3000000 cycles - for control circuit 96 W at 24 V DC-13 - electrical durability: 1000000 cycles - for control circuit | |
height | 127 mm | |
width | 85 mm | |
depth | 176 mm | |
net weight | 2.185 kg |
standards | UL 508 CSA C22.2 No 14 IEC 60947-5-1 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 | |
---|---|---|
product certifications | LROS (Lloyds register of shipping) CSA DNV RINA BV CCC UL GOST GL | |
IP degree of protection | IP2x conforming to IEC 60529 IP2x conforming to VDE 0106 | |
ambient air temperature for operation | -40…60 °C 60…70 °C with derating | |
ambient air temperature for storage | -60…80 °C | |
operating altitude | 0...3000 m | |
fire resistance | 850 °C conforming to IEC 60695-2-1 | |
shock resistance | 10 gn contactor opened 15 gn contactor closed | |
vibration resistance | 2 gn 5…300 Hz contactor opened 4 gn 5…300 Hz contactor closed |
Unit Type of Package 1 | PCE | |
---|---|---|
Number of Units in Package 1 | 1 | |
Package 1 Weight | 2.169 kg | |
Package 1 Height | 9 cm | |
Package 1 width | 14 cm | |
Package 1 Length | 18.5 cm | |
Unit Type of Package 2 | S02 | |
Number of Units in Package 2 | 2 | |
Package 2 Weight | 4.829 kg | |
Package 2 Height | 15 cm | |
Package 2 width | 30 cm | |
Package 2 Length | 40 cm | |
Unit Type of Package 3 | P06 | |
Number of Units in Package 3 | 40 | |
Package 3 Weight | 99.924 kg | |
Package 3 Height | 77 cm | |
Package 3 width | 80 cm | |
Package 3 Length | 60 cm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
REACh free of SVHC | Yes | |
EU RoHS Directive | Compliant EU RoHS Declaration | |
Toxic heavy metal free | Yes | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | China RoHS declaration Pro-active China RoHS declaration (out of China RoHS legal scope) | |
Environmental Disclosure | ||
Circularity Profile | ||
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | |
PVC free | Yes | |
California proposition 65 | WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov |
Warranty | 12 months |
---|