Schneider TeSys F contactor - 4P(4 NO) - AC-1 - <= 440 V 200 A - without coil
# of Pole : 4
Rp 8,526,045.00
55.00 %
Rp 18,946,767.00
Rp 18,946,767.00
Option not available
[Deskripsi] 1. product name : TeSys F 2. product or component type : Contactor 3. device short name : LC1F 4. contactor application : Resistive load 5. utilisation category : -AC-1 6. poles description : 4P 7. power pole contact composition : 4 NO 8. [Ue] rated operational voltage : <= 690 V AC 50/60 Hz 9. [Ie] rated operational current : -200 A (at <40 °C) at <= 440 V AC-1 10. [Uimp] rated impulse withstand voltage : 8 kV 11. overvoltage category : III 12. [Ith] conventional free air thermal current : 200 A (at 40 °C) 13. Irms rated making capacity : 1150 A conforming to IEC 60947-4-1 14. rated breaking capacity : 920 A conforming to IEC 60947-4-1 15. [Icw] rated short-time withstand current : -1100 A 40 °C - 10 s -640 A 40 °C - 30 s -520 A 40 °C - 1 min -400 A 40 °C - 3 min -320 A 40 °C - 10 min 16. associated fuse rating : -125 A aM at <= 440 V -200 A gG at <= 440 V 17. average impedance : 0.37 mOhm - Ith 200 A 50 Hz 18. [Ui] rated insulation voltage : -1000 V conforming to IEC 60947-4-1 -1500 V conforming to VDE 0110 group C 19. power dissipation per pole : -15 W AC-1 -5 W AC-3 20. mounting support : Plate 21. standards : -EN 60947-1 -JIS C8201-4-1 -IEC 60947-4-1 -EN 60947-4-1 -IEC 60947-1 22. product certifications : -RINA -ABS -CSA -DNV -RMRoS -BV -LROS (Lloyds register of shipping) -UL -CB 23. connections - terminals : -Power circuit: lugs-ring terminals 1 cable(s) 95 mm² -Power circuit: connector 1 cable(s) 95 mm² -Power circuit: bar 2 cable(s) - busbar cross section: 20 x 3 mm -Power circuit: bolted connection 24. tightening torque : Power circuit: 10 N.m 25. IP degree of protection : -IP2x front face with shrouds conforming to IEC 60529 -IP2x front face with shrouds conforming to VDE 0106 26. protective treatment : TH 27. ambient air temperature for operation : -5…55 °C 28. ambient air temperature for storage : -60…80 °C 29. permissible ambient air temperature around the device : -40…70 °C 30. operating altitude : 3000 m without 31. mechanical robustness : -Vibrations contactor open: 2 Gn, 5...300 Hz -Vibrations contactor closed: 6 Gn, 5...300 Hz -Shocks contactor open: 9 Gn for 1/2 sine wave (11 ms) -Shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms) 32. height : 162 mm 33. width : 163.5 mm 34. depth : 171 mm 35. net weight : 3.83 kg
range | TeSys | |
---|---|---|
product name | TeSys F | |
product or component type | Contactor | |
device short name | LC1F | |
contactor application | Resistive load | |
utilisation category | AC-1 | |
poles description | 4P | |
power pole contact composition | 4 NO | |
[Ue] rated operational voltage | <= 690 V AC 50/60 Hz | |
[Ie] rated operational current | 200 A (at <40 °C) at <= 440 V AC-1 |
[Uc] control circuit voltage | 24...575 V AC 40...400 Hz with LX9 coil 24...460 V DC with LX4 coil 100...250 V AC 50/60 Hz with LXE coil 100...380 V DC with LXE coil | |
---|---|---|
[Uimp] rated impulse withstand voltage | 8 kV | |
overvoltage category | III | |
[Ith] conventional free air thermal current | 200 A (at 40 °C) | |
Irms rated making capacity | 1150 A conforming to IEC 60947-4-1 | |
rated breaking capacity | 920 A conforming to IEC 60947-4-1 | |
[Icw] rated short-time withstand current | 1100 A 40 °C - 10 s 640 A 40 °C - 30 s 520 A 40 °C - 1 min 400 A 40 °C - 3 min 320 A 40 °C - 10 min | |
associated fuse rating | 200 A gG at <= 440 V | |
average impedance | 0.37 mOhm - Ith 200 A 50 Hz | |
[Ui] rated insulation voltage | 1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C | |
power dissipation per pole | 15 W AC-1 | |
control circuit voltage limits | Operational: 0.85...1.1 Uc AC 40...400 Hz with LX9 coil Drop-out: 0.2...0.55 Uc AC 40...400 Hz with LX9 coil Operational: 0.85...1.1 Uc DC with LX4 coil Drop-out: 0.15...0.2 Uc DC with LX4 coil Operational: 85...275 V AC 50/60 Hz with LXE coil Drop-out: 0...60 V AC 50/60 Hz with LXE coil Operational: 85...418 V DC with LXE coil Drop-out: 0...45 V DC with LXE coil | |
heat dissipation | 5.9…7.2 W 2.2…5.5 W | |
operating time | 130 ms opening for with LX9 coil 30...40 ms closing for with LX4 coil 30...50 ms opening for with LX4 coil 40...80 ms closing for with LXE coil 6...54 ms opening for with LXE coil | |
mounting support | Plate | |
standards | EN 60947-4-1 IEC 60947-4-1 JIS C8201-4-1 EN 60947-1 IEC 60947-1 | |
product certifications | CB UL RINA DNV LROS (Lloyds register of shipping) RMRoS CSA ABS BV UKCA | |
connections - terminals | Power circuit: lugs-ring terminals 1 cable(s) 95 mm² Power circuit: connector 1 cable(s) 95 mm² Power circuit: bar 2 cable(s) - busbar cross section: 20 x 3 mm Power circuit: bolted connection Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²solid without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm² Control circuit: screw clamp terminals 2 cable(s) 1…4 mm² Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²flexible without cable end Control circuit: screw clamp terminals 1.0 cable(s) 0.25…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²solid without cable end | |
tightening torque | Power circuit: 10 N.m Control circuit: 1.2 N.m Control circuit: 0.6 N.m | |
inrush power in VA | 590…855 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX9 coil 543…665 VA (at 20 °C)with LX4 coil 280…310 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil 270…320 VA (at 20 °C)with LXE coil | |
hold-in power consumption in VA | 6.6…8.1 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX9 coil 3.94…4.83 VA (at 20 °C)with LX4 coil 4.5…7.0 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil 2.5…4.0 VA (at 20 °C)with LXE coil | |
maximum operating rate | 2400 cyc/h 55 °C | |
compatibility code | LC1F |
IP degree of protection | IP2x front face with shrouds conforming to IEC 60529 IP2x front face with shrouds conforming to VDE 0106 | |
---|---|---|
protective treatment | TH | |
ambient air temperature for operation | -40…60 °C | |
ambient air temperature for storage | -60…80 °C | |
permissible ambient air temperature around the device | 60…70 °C at Uc | |
operating altitude | 3000 m without derating | |
mechanical robustness | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 6 Gn, 5...300 Hz Shocks contactor open: 9 Gn for 1/2 sine wave (11 ms) Shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms) | |
height | 162 mm | |
width | 200.5 mm | |
depth | 171 mm | |
net weight | 3.83 kg |
Unit Type of Package 1 | PCE | |
---|---|---|
Number of Units in Package 1 | 1 | |
Package 1 Weight | 4.208 kg | |
Package 1 Height | 18.6 cm | |
Package 1 width | 20 cm | |
Package 1 Length | 22.4 cm | |
Unit Type of Package 2 | CAR | |
Number of Units in Package 2 | 1 | |
Package 2 Weight | 4.208 kg | |
Package 2 Height | 21.5 cm | |
Package 2 width | 20 cm | |
Package 2 Length | 26.5 cm | |
Unit Type of Package 3 | P06 | |
Number of Units in Package 3 | 18 | |
Package 3 Weight | 84.244 kg | |
Package 3 Height | 80 cm | |
Package 3 width | 80 cm | |
Package 3 Length | 60 cm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
EU RoHS Directive | Compliant EU RoHS Declaration | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | China RoHS declaration Product out of China RoHS scope. Substance declaration for your information | |
Environmental Disclosure | ||
Circularity Profile | ||
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Warranty | 12 months |
---|
Specifications for Schneider TeSys F contactor - 4P(4 NO) - AC-1 - <= 440 V 200 A - without coil
# of Pole | 4 |
Filter By
[Deskripsi] 1. product name : TeSys F 2. product or component type : Contactor 3. device short name : LC1F 4. contactor application : Resistive load 5. utilisation category : -AC-1 6. poles description : 4P 7. power pole contact composition : 4 NO 8. [Ue] rated operational voltage : <= 690 V AC 50/60 Hz 9. [Ie] rated operational current : -200 A (at <40 °C) at <= 440 V AC-1 10. [Uimp] rated impulse withstand voltage : 8 kV 11. overvoltage category : III 12. [Ith] conventional free air thermal current : 200 A (at 40 °C) 13. Irms rated making capacity : 1150 A conforming to IEC 60947-4-1 14. rated breaking capacity : 920 A conforming to IEC 60947-4-1 15. [Icw] rated short-time withstand current : -1100 A 40 °C - 10 s -640 A 40 °C - 30 s -520 A 40 °C - 1 min -400 A 40 °C - 3 min -320 A 40 °C - 10 min 16. associated fuse rating : -125 A aM at <= 440 V -200 A gG at <= 440 V 17. average impedance : 0.37 mOhm - Ith 200 A 50 Hz 18. [Ui] rated insulation voltage : -1000 V conforming to IEC 60947-4-1 -1500 V conforming to VDE 0110 group C 19. power dissipation per pole : -15 W AC-1 -5 W AC-3 20. mounting support : Plate 21. standards : -EN 60947-1 -JIS C8201-4-1 -IEC 60947-4-1 -EN 60947-4-1 -IEC 60947-1 22. product certifications : -RINA -ABS -CSA -DNV -RMRoS -BV -LROS (Lloyds register of shipping) -UL -CB 23. connections - terminals : -Power circuit: lugs-ring terminals 1 cable(s) 95 mm² -Power circuit: connector 1 cable(s) 95 mm² -Power circuit: bar 2 cable(s) - busbar cross section: 20 x 3 mm -Power circuit: bolted connection 24. tightening torque : Power circuit: 10 N.m 25. IP degree of protection : -IP2x front face with shrouds conforming to IEC 60529 -IP2x front face with shrouds conforming to VDE 0106 26. protective treatment : TH 27. ambient air temperature for operation : -5…55 °C 28. ambient air temperature for storage : -60…80 °C 29. permissible ambient air temperature around the device : -40…70 °C 30. operating altitude : 3000 m without 31. mechanical robustness : -Vibrations contactor open: 2 Gn, 5...300 Hz -Vibrations contactor closed: 6 Gn, 5...300 Hz -Shocks contactor open: 9 Gn for 1/2 sine wave (11 ms) -Shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms) 32. height : 162 mm 33. width : 163.5 mm 34. depth : 171 mm 35. net weight : 3.83 kg
range | TeSys | |
---|---|---|
product name | TeSys F | |
product or component type | Contactor | |
device short name | LC1F | |
contactor application | Resistive load | |
utilisation category | AC-1 | |
poles description | 4P | |
power pole contact composition | 4 NO | |
[Ue] rated operational voltage | <= 690 V AC 50/60 Hz | |
[Ie] rated operational current | 200 A (at <40 °C) at <= 440 V AC-1 |
[Uc] control circuit voltage | 24...575 V AC 40...400 Hz with LX9 coil 24...460 V DC with LX4 coil 100...250 V AC 50/60 Hz with LXE coil 100...380 V DC with LXE coil | |
---|---|---|
[Uimp] rated impulse withstand voltage | 8 kV | |
overvoltage category | III | |
[Ith] conventional free air thermal current | 200 A (at 40 °C) | |
Irms rated making capacity | 1150 A conforming to IEC 60947-4-1 | |
rated breaking capacity | 920 A conforming to IEC 60947-4-1 | |
[Icw] rated short-time withstand current | 1100 A 40 °C - 10 s 640 A 40 °C - 30 s 520 A 40 °C - 1 min 400 A 40 °C - 3 min 320 A 40 °C - 10 min | |
associated fuse rating | 200 A gG at <= 440 V | |
average impedance | 0.37 mOhm - Ith 200 A 50 Hz | |
[Ui] rated insulation voltage | 1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C | |
power dissipation per pole | 15 W AC-1 | |
control circuit voltage limits | Operational: 0.85...1.1 Uc AC 40...400 Hz with LX9 coil Drop-out: 0.2...0.55 Uc AC 40...400 Hz with LX9 coil Operational: 0.85...1.1 Uc DC with LX4 coil Drop-out: 0.15...0.2 Uc DC with LX4 coil Operational: 85...275 V AC 50/60 Hz with LXE coil Drop-out: 0...60 V AC 50/60 Hz with LXE coil Operational: 85...418 V DC with LXE coil Drop-out: 0...45 V DC with LXE coil | |
heat dissipation | 5.9…7.2 W 2.2…5.5 W | |
operating time | 130 ms opening for with LX9 coil 30...40 ms closing for with LX4 coil 30...50 ms opening for with LX4 coil 40...80 ms closing for with LXE coil 6...54 ms opening for with LXE coil | |
mounting support | Plate | |
standards | EN 60947-4-1 IEC 60947-4-1 JIS C8201-4-1 EN 60947-1 IEC 60947-1 | |
product certifications | CB UL RINA DNV LROS (Lloyds register of shipping) RMRoS CSA ABS BV UKCA | |
connections - terminals | Power circuit: lugs-ring terminals 1 cable(s) 95 mm² Power circuit: connector 1 cable(s) 95 mm² Power circuit: bar 2 cable(s) - busbar cross section: 20 x 3 mm Power circuit: bolted connection Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²solid without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm² Control circuit: screw clamp terminals 2 cable(s) 1…4 mm² Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²flexible without cable end Control circuit: screw clamp terminals 1.0 cable(s) 0.25…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²solid without cable end | |
tightening torque | Power circuit: 10 N.m Control circuit: 1.2 N.m Control circuit: 0.6 N.m | |
inrush power in VA | 590…855 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX9 coil 543…665 VA (at 20 °C)with LX4 coil 280…310 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil 270…320 VA (at 20 °C)with LXE coil | |
hold-in power consumption in VA | 6.6…8.1 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX9 coil 3.94…4.83 VA (at 20 °C)with LX4 coil 4.5…7.0 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil 2.5…4.0 VA (at 20 °C)with LXE coil | |
maximum operating rate | 2400 cyc/h 55 °C | |
compatibility code | LC1F |
IP degree of protection | IP2x front face with shrouds conforming to IEC 60529 IP2x front face with shrouds conforming to VDE 0106 | |
---|---|---|
protective treatment | TH | |
ambient air temperature for operation | -40…60 °C | |
ambient air temperature for storage | -60…80 °C | |
permissible ambient air temperature around the device | 60…70 °C at Uc | |
operating altitude | 3000 m without derating | |
mechanical robustness | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 6 Gn, 5...300 Hz Shocks contactor open: 9 Gn for 1/2 sine wave (11 ms) Shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms) | |
height | 162 mm | |
width | 200.5 mm | |
depth | 171 mm | |
net weight | 3.83 kg |
Unit Type of Package 1 | PCE | |
---|---|---|
Number of Units in Package 1 | 1 | |
Package 1 Weight | 4.208 kg | |
Package 1 Height | 18.6 cm | |
Package 1 width | 20 cm | |
Package 1 Length | 22.4 cm | |
Unit Type of Package 2 | CAR | |
Number of Units in Package 2 | 1 | |
Package 2 Weight | 4.208 kg | |
Package 2 Height | 21.5 cm | |
Package 2 width | 20 cm | |
Package 2 Length | 26.5 cm | |
Unit Type of Package 3 | P06 | |
Number of Units in Package 3 | 18 | |
Package 3 Weight | 84.244 kg | |
Package 3 Height | 80 cm | |
Package 3 width | 80 cm | |
Package 3 Length | 60 cm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
EU RoHS Directive | Compliant EU RoHS Declaration | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | China RoHS declaration Product out of China RoHS scope. Substance declaration for your information | |
Environmental Disclosure | ||
Circularity Profile | ||
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Warranty | 12 months |
---|