• Sign up now and get discount up to 47%

Schneider TeSys F contactor - 3P(3 NO) - AC-3 - <= 440 V 400 A - without coil

# of Pole : 3

Rp 42.477.480,00 Rp 18.690.091,00 18690091 IDR

Rp 42.477.480,00

Option not available

  • # of Pole

This combination does not exist.

Add to Cart

Schneider TeSys F contactor - 3P(3 NO) - AC-3 - <= 440 V 400 A - without coil
Terjual 0
0 (0 Rating)
Ulasan (0)

Rp 18.690.091,00
56.00 % Rp 42.477.480,00 18690091 IDR

Rp 42.477.480,00

Option not available

Atur Jumlah & Catatan
Stock Total: 2

# of Pole : 3

Spesifikasi

[Deskripsi] 1. product name : TeSys F 2. product or component type : Contactor 3. device short name : LC1F 4. contactor application : -Resistive load -Motor control 5. utilisation category : -AC-1 -AC-4 -AC-3 6. poles description : 3P 7. power pole contact composition : 3 NO 8. [Ue] rated operational voltage : -<= 1000 V AC 50/60 Hz -<= 460 V DC 9. [Ie] rated operational current : -500 A (at <40 °C) at <= 440 V AC-1 -400 A (at <55 °C) at <= 440 V AC-3 10. motor power kW : -185 kW at 1000 V AC 50/60 Hz (AC-3) -200 kW at 380...400 V AC 50/60 Hz (AC-3) -220 kW at 415 V AC 50/60 Hz (AC-3) -250 kW at 440 V AC 50/60 Hz (AC-3) -257 kW at 500 V AC 50/60 Hz (AC-3) -110 kW at 220...240 V AC 50/60 Hz (AC-3) -280 kW at 660...690 V AC 50/60 Hz (AC-3) -75 kW at 400 V AC 50/60 Hz (AC-4) 11. [Uimp] rated impulse withstand voltage : 8 kV 12. overvoltage category : III 13. [Ith] conventional free air thermal current : 500 A (at 40 °C) 14. Irms rated making capacity : 4000 A conforming to IEC 60947-4-1 15. rated breaking capacity : 3200 A conforming to IEC 60947-4-1 16. [Icw] rated short-time withstand current : -3600 A 40 °C - 10 s -2400 A 40 °C - 30 s -1700 A 40 °C - 1 min -1200 A 40 °C - 3 min -1000 A 40 °C - 10 min 17. associated fuse rating : -400 A aM at <= 440 V -500 A gG at <= 440 V 18. average impedance : 0.26 mOhm - Ith 500 A 50 Hz 19. [Ui] rated insulation voltage : -1000 V conforming to IEC 60947-4-1 -1500 V conforming to VDE 0110 group C 20. power dissipation per pole : -65 W AC-1 -42 W AC-3 21. mounting support : Plate 22. standards : -EN 60947-1 -JIS C8201-4-1 -IEC 60947-4-1 -EN 60947-4-1 -IEC 60947-1 23. product certifications : -RINA -ABS -CSA -DNV -RMRoS -BV -LROS (Lloyds register of shipping) -UL -CB 24. connections - terminals : -Power circuit: lugs-ring terminals 1 cable(s) 95 mm² -Power circuit: connector 1 cable(s) 95 mm² -Power circuit: bar 2 cable(s) - busbar cross section: 20 x 3 mm -Power circuit: bolted connection 25. tightening torque : Power circuit: 18 N.m 26. IP degree of protection : -IP2x front face with shrouds conforming to IEC 60529 -IP2x front face with shrouds conforming to VDE 0106 27. protective treatment : TH 28. ambient air temperature for operation : -5…55 °C 29. ambient air temperature for storage : -60…80 °C 30. permissible ambient air temperature around the device : -40…70 °C 31. operating altitude : 3000 m without 32. mechanical robustness : -Vibrations contactor open: 2 Gn, 5...300 Hz -Vibrations contactor closed: 6 Gn, 5...300 Hz -Shocks contactor open: 9 Gn for 1/2 sine wave (11 ms) -Shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms) 33. height : 206 mm 34. width : 213 mm 35. depth : 219 mm 36. net weight : 8 kg


Main (see above)
range
TeSys
product name
TeSys F
product or component type
Contactor
device short name
LC1F
contactor application
Resistive load
Motor control
utilisation category
AC-3
AC-1
AC-4
poles description
3P
power pole contact composition
3 NO
[Ue] rated operational voltage
<= 1000 V AC 50/60 Hz
<= 460 V DC
[Ie] rated operational current
500 A (at <40 °C) at <= 440 V AC AC-1
400 A (at <55 °C) at <= 440 V AC AC-3
motor power kW
185 kW at 1000 V AC 50/60 Hz (AC-3)
200 kW at 380...400 V AC 50/60 Hz (AC-3)
220 kW at 415 V AC 50/60 Hz (AC-3)
250 kW at 440 V AC 50/60 Hz (AC-3)
257 kW at 500 V AC 50/60 Hz (AC-3)
110 kW at 220...240 V AC 50/60 Hz (AC-3)
280 kW at 660...690 V AC 50/60 Hz (AC-3)
75 kW at 400 V AC 50/60 Hz (AC-4)
Complementary (see above)
[Uc] control circuit voltage
48...1000 V AC 40...400 Hz with LX1/LX9 coil
48...440 V DC with LX4 coil
100...250 V AC 50/60 Hz with LXE coil
100...380 V DC with LXE coil
[Uimp] rated impulse withstand voltage
8 kV
overvoltage category
III
[Ith] conventional free air thermal current
500 A (at 40 °C)
Irms rated making capacity
4000 A AC conforming to IEC 60947-4-1
rated breaking capacity
3200 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current
3600 A 40 °C - 10 s
2400 A 40 °C - 30 s
1700 A 40 °C - 1 min
1200 A 40 °C - 3 min
1000 A 40 °C - 10 min
associated fuse rating
400 A aM at <= 440 V
500 A gG at <= 440 V
average impedance
0.26 mOhm - Ith 500 A 50 Hz
[Ui] rated insulation voltage
1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C
power dissipation per pole
65 W AC-1
42 W AC-3
control circuit voltage limits
Operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coil
Drop-out: 0.3...0.5 Uc AC 40...400 Hz with LX1/LX9 coil
Operational: 0.85...1.1 Uc DC with LX4 coil
Drop-out: 0.2...0.35 Uc DC with LX4 coil
Operational: 85...275 V AC 50/60 Hz with LXE coil
Drop-out: 0...60 V AC 50/60 Hz with LXE coil
Operational: 85...418 V DC with LXE coil
Drop-out: 0...45 V DC with LXE coil
heat dissipation
14 W
2.2…5.5 W
operating time
40...75 ms closing for with LX1/LX9 coil
100...170 ms opening for with LX1/LX9 coil
50...60 ms closing for with LX4 coil
45...60 ms opening for with LX4 coil
40...80 ms closing for with LXE coil
6...54 ms opening for with LXE coil
mounting support
Plate
standards
JIS C8201-4-1
IEC 60947-4-1
IEC 60947-1
EN 60947-4-1
EN 60947-1
product certifications
CB
ABS
DNV
RMRoS
LROS (Lloyds register of shipping)
BV
RINA
UL
CSA
UKCA
connections - terminals
Power circuit: bar 2 cable(s) - busbar cross section: 30 x 5 mm
Power circuit: lugs-ring terminals 2 cable(s) 150 mm²
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²solid without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²
Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²flexible without cable end
Control circuit: screw clamp terminals 1.0 cable(s) 0.25…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²solid without cable end
tightening torque
Power circuit: 35 N.m
Control circuit: 1.2 N.m
Control circuit: 0.6 N.m
mechanical durability
10 Mcycles
inrush power in VA
1000…1150 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil
920…1140 VA (at 20 °C)with LX4 coil
360…470 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil
410…450 VA (at 20 °C)with LXE coil
hold-in power consumption in VA
12…18 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil
4…7.5 VA (at 20 °C)with LX4 coil
4.5…7.0 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil
2.5…4.0 VA (at 20 °C)with LXE coil
maximum operating rate
2400 cyc/h 55 °C
compatibility code
LC1F
Environment (see above)
IP degree of protection
IP20 front face with shrouds conforming to IEC 60529
IP20 front face with shrouds conforming to VDE 0106
protective treatment
TH
ambient air temperature for operation
-5…55 °C
ambient air temperature for storage
-60…80 °C
permissible ambient air temperature around the device
-40…70 °C
operating altitude
3000 m without derating
mechanical robustness
Vibrations contactor open: 1.5 Gn, 5...300 Hz
Vibrations contactor closed: 5 Gn, 5...300 Hz
Shocks contactor open: 6 Gn for 1/2 sine wave (11 ms)
Shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms)
height
206 mm
width
213 mm
depth
219 mm
net weight
8 kg
Packing Units (see above)
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Weight
8.126 kg
Package 1 Height
25 cm
Package 1 width
25.6 cm
Package 1 Length
30.4 cm
Unit Type of Package 2
CAR
Number of Units in Package 2
1
Package 2 Weight
8.126 kg
Package 2 Height
26 cm
Package 2 width
24.5 cm
Package 2 Length
32.5 cm
Unit Type of Package 3
P06
Number of Units in Package 3
10
Package 3 Weight
90.12 kg
Package 3 Height
80 cm
Package 3 width
80 cm
Package 3 Length
60 cm
Offer Sustainability (see above)
Sustainable offer status
Green Premium product
REACh Regulation
EU RoHS Directive
Mercury free
Yes
RoHS exemption information
China RoHS Regulation
China RoHS declaration
Product out of China RoHS scope. Substance declaration for your information
Environmental Disclosure
Circularity Profile
WEEE
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Contractual warranty (see above)
Warranty
12 months

Specifications for Schneider TeSys F contactor - 3P(3 NO) - AC-3 - <= 440 V 400 A - without coil

# of Pole 3

Filter By

Product Public Price Discount Guaranteed Stock QTY Action
Rp 282.206,00 100.00 % 2
Rp 2.826.859,00 100.00 % 1
Rp 1.357.263,00 100.00 % 2
Rp 1.357.263,00 100.00 % 2
Rp 1.103.295,00 100.00 %
Rp 819.535,00 100.00 % 4
HOT PROMO

[Deskripsi] 1. product name : TeSys F 2. product or component type : Contactor 3. device short name : LC1F 4. contactor application : -Resistive load -Motor control 5. utilisation category : -AC-1 -AC-4 -AC-3 6. poles description : 3P 7. power pole contact composition : 3 NO 8. [Ue] rated operational voltage : -<= 1000 V AC 50/60 Hz -<= 460 V DC 9. [Ie] rated operational current : -500 A (at <40 °C) at <= 440 V AC-1 -400 A (at <55 °C) at <= 440 V AC-3 10. motor power kW : -185 kW at 1000 V AC 50/60 Hz (AC-3) -200 kW at 380...400 V AC 50/60 Hz (AC-3) -220 kW at 415 V AC 50/60 Hz (AC-3) -250 kW at 440 V AC 50/60 Hz (AC-3) -257 kW at 500 V AC 50/60 Hz (AC-3) -110 kW at 220...240 V AC 50/60 Hz (AC-3) -280 kW at 660...690 V AC 50/60 Hz (AC-3) -75 kW at 400 V AC 50/60 Hz (AC-4) 11. [Uimp] rated impulse withstand voltage : 8 kV 12. overvoltage category : III 13. [Ith] conventional free air thermal current : 500 A (at 40 °C) 14. Irms rated making capacity : 4000 A conforming to IEC 60947-4-1 15. rated breaking capacity : 3200 A conforming to IEC 60947-4-1 16. [Icw] rated short-time withstand current : -3600 A 40 °C - 10 s -2400 A 40 °C - 30 s -1700 A 40 °C - 1 min -1200 A 40 °C - 3 min -1000 A 40 °C - 10 min 17. associated fuse rating : -400 A aM at <= 440 V -500 A gG at <= 440 V 18. average impedance : 0.26 mOhm - Ith 500 A 50 Hz 19. [Ui] rated insulation voltage : -1000 V conforming to IEC 60947-4-1 -1500 V conforming to VDE 0110 group C 20. power dissipation per pole : -65 W AC-1 -42 W AC-3 21. mounting support : Plate 22. standards : -EN 60947-1 -JIS C8201-4-1 -IEC 60947-4-1 -EN 60947-4-1 -IEC 60947-1 23. product certifications : -RINA -ABS -CSA -DNV -RMRoS -BV -LROS (Lloyds register of shipping) -UL -CB 24. connections - terminals : -Power circuit: lugs-ring terminals 1 cable(s) 95 mm² -Power circuit: connector 1 cable(s) 95 mm² -Power circuit: bar 2 cable(s) - busbar cross section: 20 x 3 mm -Power circuit: bolted connection 25. tightening torque : Power circuit: 18 N.m 26. IP degree of protection : -IP2x front face with shrouds conforming to IEC 60529 -IP2x front face with shrouds conforming to VDE 0106 27. protective treatment : TH 28. ambient air temperature for operation : -5…55 °C 29. ambient air temperature for storage : -60…80 °C 30. permissible ambient air temperature around the device : -40…70 °C 31. operating altitude : 3000 m without 32. mechanical robustness : -Vibrations contactor open: 2 Gn, 5...300 Hz -Vibrations contactor closed: 6 Gn, 5...300 Hz -Shocks contactor open: 9 Gn for 1/2 sine wave (11 ms) -Shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms) 33. height : 206 mm 34. width : 213 mm 35. depth : 219 mm 36. net weight : 8 kg


Main (see above)
range
TeSys
product name
TeSys F
product or component type
Contactor
device short name
LC1F
contactor application
Resistive load
Motor control
utilisation category
AC-3
AC-1
AC-4
poles description
3P
power pole contact composition
3 NO
[Ue] rated operational voltage
<= 1000 V AC 50/60 Hz
<= 460 V DC
[Ie] rated operational current
500 A (at <40 °C) at <= 440 V AC AC-1
400 A (at <55 °C) at <= 440 V AC AC-3
motor power kW
185 kW at 1000 V AC 50/60 Hz (AC-3)
200 kW at 380...400 V AC 50/60 Hz (AC-3)
220 kW at 415 V AC 50/60 Hz (AC-3)
250 kW at 440 V AC 50/60 Hz (AC-3)
257 kW at 500 V AC 50/60 Hz (AC-3)
110 kW at 220...240 V AC 50/60 Hz (AC-3)
280 kW at 660...690 V AC 50/60 Hz (AC-3)
75 kW at 400 V AC 50/60 Hz (AC-4)
Complementary (see above)
[Uc] control circuit voltage
48...1000 V AC 40...400 Hz with LX1/LX9 coil
48...440 V DC with LX4 coil
100...250 V AC 50/60 Hz with LXE coil
100...380 V DC with LXE coil
[Uimp] rated impulse withstand voltage
8 kV
overvoltage category
III
[Ith] conventional free air thermal current
500 A (at 40 °C)
Irms rated making capacity
4000 A AC conforming to IEC 60947-4-1
rated breaking capacity
3200 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current
3600 A 40 °C - 10 s
2400 A 40 °C - 30 s
1700 A 40 °C - 1 min
1200 A 40 °C - 3 min
1000 A 40 °C - 10 min
associated fuse rating
400 A aM at <= 440 V
500 A gG at <= 440 V
average impedance
0.26 mOhm - Ith 500 A 50 Hz
[Ui] rated insulation voltage
1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C
power dissipation per pole
65 W AC-1
42 W AC-3
control circuit voltage limits
Operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coil
Drop-out: 0.3...0.5 Uc AC 40...400 Hz with LX1/LX9 coil
Operational: 0.85...1.1 Uc DC with LX4 coil
Drop-out: 0.2...0.35 Uc DC with LX4 coil
Operational: 85...275 V AC 50/60 Hz with LXE coil
Drop-out: 0...60 V AC 50/60 Hz with LXE coil
Operational: 85...418 V DC with LXE coil
Drop-out: 0...45 V DC with LXE coil
heat dissipation
14 W
2.2…5.5 W
operating time
40...75 ms closing for with LX1/LX9 coil
100...170 ms opening for with LX1/LX9 coil
50...60 ms closing for with LX4 coil
45...60 ms opening for with LX4 coil
40...80 ms closing for with LXE coil
6...54 ms opening for with LXE coil
mounting support
Plate
standards
JIS C8201-4-1
IEC 60947-4-1
IEC 60947-1
EN 60947-4-1
EN 60947-1
product certifications
CB
ABS
DNV
RMRoS
LROS (Lloyds register of shipping)
BV
RINA
UL
CSA
UKCA
connections - terminals
Power circuit: bar 2 cable(s) - busbar cross section: 30 x 5 mm
Power circuit: lugs-ring terminals 2 cable(s) 150 mm²
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²solid without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²
Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²flexible without cable end
Control circuit: screw clamp terminals 1.0 cable(s) 0.25…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²solid without cable end
tightening torque
Power circuit: 35 N.m
Control circuit: 1.2 N.m
Control circuit: 0.6 N.m
mechanical durability
10 Mcycles
inrush power in VA
1000…1150 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil
920…1140 VA (at 20 °C)with LX4 coil
360…470 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil
410…450 VA (at 20 °C)with LXE coil
hold-in power consumption in VA
12…18 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil
4…7.5 VA (at 20 °C)with LX4 coil
4.5…7.0 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil
2.5…4.0 VA (at 20 °C)with LXE coil
maximum operating rate
2400 cyc/h 55 °C
compatibility code
LC1F
Environment (see above)
IP degree of protection
IP20 front face with shrouds conforming to IEC 60529
IP20 front face with shrouds conforming to VDE 0106
protective treatment
TH
ambient air temperature for operation
-5…55 °C
ambient air temperature for storage
-60…80 °C
permissible ambient air temperature around the device
-40…70 °C
operating altitude
3000 m without derating
mechanical robustness
Vibrations contactor open: 1.5 Gn, 5...300 Hz
Vibrations contactor closed: 5 Gn, 5...300 Hz
Shocks contactor open: 6 Gn for 1/2 sine wave (11 ms)
Shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms)
height
206 mm
width
213 mm
depth
219 mm
net weight
8 kg
Packing Units (see above)
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Weight
8.126 kg
Package 1 Height
25 cm
Package 1 width
25.6 cm
Package 1 Length
30.4 cm
Unit Type of Package 2
CAR
Number of Units in Package 2
1
Package 2 Weight
8.126 kg
Package 2 Height
26 cm
Package 2 width
24.5 cm
Package 2 Length
32.5 cm
Unit Type of Package 3
P06
Number of Units in Package 3
10
Package 3 Weight
90.12 kg
Package 3 Height
80 cm
Package 3 width
80 cm
Package 3 Length
60 cm
Offer Sustainability (see above)
Sustainable offer status
Green Premium product
REACh Regulation
EU RoHS Directive
Mercury free
Yes
RoHS exemption information
China RoHS Regulation
China RoHS declaration
Product out of China RoHS scope. Substance declaration for your information
Environmental Disclosure
Circularity Profile
WEEE
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Contractual warranty (see above)
Warranty
12 months