Schneider TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 380...400 V AC coil
# of Pole : 3
Arus Pengenal (A) : 9A
Coil AC : 380V (Q7)
Rp 254,818.00
44.00 %
Rp 455,033.00
Rp 455,033.00
Option not available
[Deskripsi] 1. product name : TeSys K 2. device short name : LC1K 3. device application : Control 4. contactor application : -Motor control -Resistive load 5. utilisation category : -AC-4 -AC-1 -AC-3 6. poles description : 3P 7. power pole contact composition : 3 NO 8. [Ie] rated operational current : -20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit -9 A at <= 440 V AC AC-3 for power circuit -16 A (at <70 °C) at 690 V AC AC-1 for power circuit 9. control circuit type : AC at 50/60 Hz 10. [Uc] control circuit voltage : 380...400 V AC 50/60 Hz 11. motor power kW : -2.2 kW at 220...230 V AC 50/60 Hz AC-3 -4 kW at 380...415 V AC 50/60 Hz AC-3 -4 kW at 440 V AC 50/60 Hz AC-3 -4 kW at 480 V AC 50/60 Hz AC-3 -4 kW at 500...600 V AC 50/60 Hz AC-3 -4 kW at 660...690 V AC 50/60 Hz AC-3 -2.2 kW at 400 V AC 50/60 Hz AC-4 12. auxiliary contact composition : 1 NO 13. overvoltage category : III 14. [Ith] conventional free air thermal current : -20 A (at 50 °C) for power circuit -10 A (at 50 °C) for signalling circuit 15. Irms rated making capacity : -110 A AC for power circuit conforming to NF C 63-110 -110 A AC for power circuit conforming to IEC 60947 -110 A AC for signalling circuit conforming to IEC 60947 16. rated breaking capacity : -110 A at 415 V conforming to IEC 60947 -110 A at 440 V conforming to IEC 60947 -80 A at 500 V conforming to IEC 60947 -110 A at 220...230 V conforming to IEC 60947 -110 A at 380...400 V conforming to IEC 60947 -70 A at 660...690 V conforming to IEC 60947 17. associated fuse rating : -25 A gG at <= 440 V for power circuit -25 A aM for power circuit -10 A gG for signalling circuit conforming to IEC 60947 -10 A gG for signalling circuit conforming to VDE 0660 18. average impedance : 3 mOhm - Ith 20 A 50 Hz for power circuit 19. insulation resistance : > 10 MOhm for signalling circuit 20. inrush power in VA : 30 VA (at 20 °C) 21. hold-in power consumption in VA : 4.5 VA (at 20 °C) 22. heat dissipation : 1.3 W 23. control circuit voltage limits : -Operational: 0.8...1.15 Uc (at <50 °C) -Drop-out: 0.2...0.75 Uc (at <50 °C) 24. maximum operating rate : 3600 cyc/h 25. auxiliary contacts type : type instantaneous 1 NO 26. signalling circuit frequency : <= 400 Hz 27. minimum switching current : 5 mA for signalling circuit 28. minimum switching voltage : 17 V for signalling circuit 29. operating time : -10...20 ms coil de-energisation and NO opening -10...20 ms coil energisation and NO closing 30. safety reliability level : -B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 -B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 31. non overlap distance : 0.5 mm 32. mechanical robustness : -Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 -Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 -Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 -Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 -Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 -Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 -Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 -Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 33. height : 58 mm 34. width : 45 mm 35. depth : 57 mm 36. net weight : 0.18 kg
range | TeSys | |
---|---|---|
product or component type | Contactor | |
product name | TeSys K | |
device application | Control | |
contactor application | Motor control Resistive load |
utilisation category | AC-1 AC-4 AC-3 | |
---|---|---|
poles description | 3P | |
power pole contact composition | 3 NO | |
[Ie] rated operational current | 20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit 9 A at <= 440 V AC AC-3 for power circuit 16 A (at <70 °C) at 690 V AC AC-1 for power circuit | |
control circuit type | AC at 50/60 Hz | |
[Uc] control circuit voltage | 380...400 V AC 50/60 Hz | |
motor power kW | 2.2 kW at 220...230 V AC 50/60 Hz AC-3 4 kW at 380...415 V AC 50/60 Hz AC-3 4 kW at 440 V AC 50/60 Hz AC-3 4 kW at 480 V AC 50/60 Hz AC-3 4 kW at 500...600 V AC 50/60 Hz AC-3 4 kW at 660...690 V AC 50/60 Hz AC-3 2.2 kW at 400 V AC 50/60 Hz AC-4 | |
auxiliary contact composition | 1 NO | |
overvoltage category | III | |
[Ith] conventional free air thermal current | 20 A (at 50 °C) for power circuit 10 A (at 50 °C) for signalling circuit | |
Irms rated making capacity | 110 A AC for power circuit conforming to NF C 63-110 110 A AC for power circuit conforming to IEC 60947 110 A AC for signalling circuit conforming to IEC 60947 | |
rated breaking capacity | 110 A at 415 V conforming to IEC 60947 110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 110 A at 220...230 V conforming to IEC 60947 110 A at 380...400 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947 | |
associated fuse rating | 25 A gG at <= 440 V for power circuit 25 A aM for power circuit 10 A gG for signalling circuit conforming to IEC 60947 10 A gG for signalling circuit conforming to VDE 0660 | |
average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit | |
insulation resistance | > 10 MOhm for signalling circuit | |
inrush power in VA | 30 VA (at 20 °C) | |
hold-in power consumption in VA | 4.5 VA (at 20 °C) | |
heat dissipation | 1.3 W | |
control circuit voltage limits | Operational: 0.8...1.15 Uc (at <50 °C) Drop-out: 0.2...0.75 Uc (at <50 °C) | |
maximum operating rate | 3600 cyc/h | |
auxiliary contacts type | type instantaneous 1 NO | |
signalling circuit frequency | <= 400 Hz | |
minimum switching current | 5 mA for signalling circuit | |
minimum switching voltage | 17 V for signalling circuit | |
operating time | 10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing | |
safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | |
non overlap distance | 0.5 mm | |
mechanical robustness | Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 | |
net weight | 0.18 kg |
standards | BS 5424 IEC 60947 NF C 63-110 VDE 0660 | |
---|---|---|
product certifications | UL CSA | |
protective treatment | TC conforming to IEC 60068 TC conforming to DIN 50016 | |
ambient air temperature for storage | -50…80 °C | |
operating altitude | 2000 m without derating | |
flame retardance | V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102 |
Unit Type of Package 1 | PCE | |
---|---|---|
Number of Units in Package 1 | 1 | |
Package 1 Weight | 176 g | |
Package 1 Height | 4.8 cm | |
Package 1 width | 6.2 cm | |
Package 1 Length | 6.6 cm | |
Unit Type of Package 2 | S02 | |
Number of Units in Package 2 | 50 | |
Package 2 Weight | 9.236 kg | |
Package 2 Height | 15 cm | |
Package 2 width | 30 cm | |
Package 2 Length | 40 cm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
REACh free of SVHC | Yes | |
EU RoHS Directive | Compliant EU RoHS Declaration | |
Toxic heavy metal free | Yes | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | China RoHS declaration Pro-active China RoHS declaration (out of China RoHS legal scope) | |
Environmental Disclosure | ||
Circularity Profile | ||
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | |
California proposition 65 | WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov |
Warranty | 12 months |
---|
Specifications for Schneider TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 380...400 V AC coil
General Information | |
---|---|
# of Pole | 3 |
Arus Pengenal (A) | 9A |
Uncategorized | |
Coil AC | 380V (Q7) |
[Deskripsi] 1. product name : TeSys K 2. device short name : LC1K 3. device application : Control 4. contactor application : -Motor control -Resistive load 5. utilisation category : -AC-4 -AC-1 -AC-3 6. poles description : 3P 7. power pole contact composition : 3 NO 8. [Ie] rated operational current : -20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit -9 A at <= 440 V AC AC-3 for power circuit -16 A (at <70 °C) at 690 V AC AC-1 for power circuit 9. control circuit type : AC at 50/60 Hz 10. [Uc] control circuit voltage : 380...400 V AC 50/60 Hz 11. motor power kW : -2.2 kW at 220...230 V AC 50/60 Hz AC-3 -4 kW at 380...415 V AC 50/60 Hz AC-3 -4 kW at 440 V AC 50/60 Hz AC-3 -4 kW at 480 V AC 50/60 Hz AC-3 -4 kW at 500...600 V AC 50/60 Hz AC-3 -4 kW at 660...690 V AC 50/60 Hz AC-3 -2.2 kW at 400 V AC 50/60 Hz AC-4 12. auxiliary contact composition : 1 NO 13. overvoltage category : III 14. [Ith] conventional free air thermal current : -20 A (at 50 °C) for power circuit -10 A (at 50 °C) for signalling circuit 15. Irms rated making capacity : -110 A AC for power circuit conforming to NF C 63-110 -110 A AC for power circuit conforming to IEC 60947 -110 A AC for signalling circuit conforming to IEC 60947 16. rated breaking capacity : -110 A at 415 V conforming to IEC 60947 -110 A at 440 V conforming to IEC 60947 -80 A at 500 V conforming to IEC 60947 -110 A at 220...230 V conforming to IEC 60947 -110 A at 380...400 V conforming to IEC 60947 -70 A at 660...690 V conforming to IEC 60947 17. associated fuse rating : -25 A gG at <= 440 V for power circuit -25 A aM for power circuit -10 A gG for signalling circuit conforming to IEC 60947 -10 A gG for signalling circuit conforming to VDE 0660 18. average impedance : 3 mOhm - Ith 20 A 50 Hz for power circuit 19. insulation resistance : > 10 MOhm for signalling circuit 20. inrush power in VA : 30 VA (at 20 °C) 21. hold-in power consumption in VA : 4.5 VA (at 20 °C) 22. heat dissipation : 1.3 W 23. control circuit voltage limits : -Operational: 0.8...1.15 Uc (at <50 °C) -Drop-out: 0.2...0.75 Uc (at <50 °C) 24. maximum operating rate : 3600 cyc/h 25. auxiliary contacts type : type instantaneous 1 NO 26. signalling circuit frequency : <= 400 Hz 27. minimum switching current : 5 mA for signalling circuit 28. minimum switching voltage : 17 V for signalling circuit 29. operating time : -10...20 ms coil de-energisation and NO opening -10...20 ms coil energisation and NO closing 30. safety reliability level : -B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 -B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 31. non overlap distance : 0.5 mm 32. mechanical robustness : -Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 -Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 -Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 -Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 -Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 -Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 -Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 -Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 33. height : 58 mm 34. width : 45 mm 35. depth : 57 mm 36. net weight : 0.18 kg
range | TeSys | |
---|---|---|
product or component type | Contactor | |
product name | TeSys K | |
device application | Control | |
contactor application | Motor control Resistive load |
utilisation category | AC-1 AC-4 AC-3 | |
---|---|---|
poles description | 3P | |
power pole contact composition | 3 NO | |
[Ie] rated operational current | 20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit 9 A at <= 440 V AC AC-3 for power circuit 16 A (at <70 °C) at 690 V AC AC-1 for power circuit | |
control circuit type | AC at 50/60 Hz | |
[Uc] control circuit voltage | 380...400 V AC 50/60 Hz | |
motor power kW | 2.2 kW at 220...230 V AC 50/60 Hz AC-3 4 kW at 380...415 V AC 50/60 Hz AC-3 4 kW at 440 V AC 50/60 Hz AC-3 4 kW at 480 V AC 50/60 Hz AC-3 4 kW at 500...600 V AC 50/60 Hz AC-3 4 kW at 660...690 V AC 50/60 Hz AC-3 2.2 kW at 400 V AC 50/60 Hz AC-4 | |
auxiliary contact composition | 1 NO | |
overvoltage category | III | |
[Ith] conventional free air thermal current | 20 A (at 50 °C) for power circuit 10 A (at 50 °C) for signalling circuit | |
Irms rated making capacity | 110 A AC for power circuit conforming to NF C 63-110 110 A AC for power circuit conforming to IEC 60947 110 A AC for signalling circuit conforming to IEC 60947 | |
rated breaking capacity | 110 A at 415 V conforming to IEC 60947 110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 110 A at 220...230 V conforming to IEC 60947 110 A at 380...400 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947 | |
associated fuse rating | 25 A gG at <= 440 V for power circuit 25 A aM for power circuit 10 A gG for signalling circuit conforming to IEC 60947 10 A gG for signalling circuit conforming to VDE 0660 | |
average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit | |
insulation resistance | > 10 MOhm for signalling circuit | |
inrush power in VA | 30 VA (at 20 °C) | |
hold-in power consumption in VA | 4.5 VA (at 20 °C) | |
heat dissipation | 1.3 W | |
control circuit voltage limits | Operational: 0.8...1.15 Uc (at <50 °C) Drop-out: 0.2...0.75 Uc (at <50 °C) | |
maximum operating rate | 3600 cyc/h | |
auxiliary contacts type | type instantaneous 1 NO | |
signalling circuit frequency | <= 400 Hz | |
minimum switching current | 5 mA for signalling circuit | |
minimum switching voltage | 17 V for signalling circuit | |
operating time | 10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing | |
safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | |
non overlap distance | 0.5 mm | |
mechanical robustness | Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 | |
net weight | 0.18 kg |
standards | BS 5424 IEC 60947 NF C 63-110 VDE 0660 | |
---|---|---|
product certifications | UL CSA | |
protective treatment | TC conforming to IEC 60068 TC conforming to DIN 50016 | |
ambient air temperature for storage | -50…80 °C | |
operating altitude | 2000 m without derating | |
flame retardance | V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102 |
Unit Type of Package 1 | PCE | |
---|---|---|
Number of Units in Package 1 | 1 | |
Package 1 Weight | 176 g | |
Package 1 Height | 4.8 cm | |
Package 1 width | 6.2 cm | |
Package 1 Length | 6.6 cm | |
Unit Type of Package 2 | S02 | |
Number of Units in Package 2 | 50 | |
Package 2 Weight | 9.236 kg | |
Package 2 Height | 15 cm | |
Package 2 width | 30 cm | |
Package 2 Length | 40 cm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
REACh free of SVHC | Yes | |
EU RoHS Directive | Compliant EU RoHS Declaration | |
Toxic heavy metal free | Yes | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | China RoHS declaration Pro-active China RoHS declaration (out of China RoHS legal scope) | |
Environmental Disclosure | ||
Circularity Profile | ||
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | |
California proposition 65 | WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov |
Warranty | 12 months |
---|