    [Deskripsi] 1. product name : TeSys LRK 2. product or component type : Differential thermal overload relay 3. device short name : LR2K 4. relay application : Motor protection 5. product compatibility : -LP4K -LC1K -LP1K -LC7K 6. network type : -DC -AC 7. thermal overload class : Class 10A conforming to IEC 60947-4-1 8. thermal protection adjustment range : 2.6…3.7 A 9. [Ui] rated insulation voltage : -Power circuit: 690 V conforming to BS 4941 -Power circuit: 690 V conforming to IEC 60947 -Power circuit: 750 V conforming to VDE 0110 group C -Power circuit: 600 V conforming to CSA C22.2 No 14 10. network frequency : <= 400 Hz 11. mounting support : -Under contactor -Plate, with specific accessories -Rail, with specific accessories 12. auxiliary contact composition : 1 NO + 1 NC 13. [Ith] conventional free air thermal current : 6 A for signalling circuit 14. [Ue] rated operational voltage : -<= 690 V for power circuit -690 V AC AC-15 for signalling circuit -250 V DC DC-13 for signalling circuit 15. associated fuse rating : -6 A gG for signalling circuit conforming to VDE 0660 -6 A gG for signalling circuit conforming to IEC 60947 16. [Uimp] rated impulse withstand voltage : 6 kV 17. power dissipation per pole : 2 W 18. phase failure sensitivity : Yes conforming to IEC 60947-4-1 19. local signalling : Trip indicator (yellow) 20. control type : -Red push-button: trip test function -Blue push-button: stop and manual reset -selector switch: manual or automatic reset 21. connections - terminals : -Screw clamp terminals 1 cable(s) 1.5…4 mm²solid -Screw clamp terminals 2 cable(s) 1.5…4 mm²solid -Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end -Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end -Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end -Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end 22. tightening torque : -1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2 -1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm 23. height : 58 mm 24. width : 45 mm 25. depth : 65 mm 26. net weight : 0.145 kg


    Main (see above)
    range
    TeSys
    product name
    TeSys LRK
    product or component type
    Differential thermal overload relay
    device short name
    LR2K
    relay application
    Motor protection
    product compatibility
    LC7K
    LP1K
    LP4K
    LC1K
    network type
    DC
    AC
    thermal overload class
    Class 10A conforming to IEC 60947-4-1
    thermal protection adjustment range
    2.6…3.7 A
    [Ui] rated insulation voltage
    Power circuit: 690 V conforming to BS 4941
    Power circuit: 690 V conforming to IEC 60947
    Power circuit: 750 V conforming to VDE 0110 group C
    Power circuit: 600 V conforming to CSA C22.2 No 14
    Complementary (see above)
    network frequency
    <= 400 Hz
    mounting support
    Under contactor
    Plate, with specific accessories
    Rail, with specific accessories
    auxiliary contact composition
    1 NO + 1 NC
    [Ith] conventional free air thermal current
    6 A for signalling circuit
    [Ue] rated operational voltage
    <= 690 V for power circuit
    690 V AC AC-15 for signalling circuit
    250 V DC DC-13 for signalling circuit
    associated fuse rating
    6 A gG for signalling circuit conforming to VDE 0660
    6 A gG for signalling circuit conforming to IEC 60947
    [Uimp] rated impulse withstand voltage
    6 kV
    power dissipation per pole
    2 W
    phase failure sensitivity
    Yes conforming to IEC 60947-4-1
    local signalling
    Trip indicator (yellow)
    control type
    Red push-button: trip test function
    Blue push-button: stop and manual reset
    selector switch: manual or automatic reset
    connections - terminals
    Screw clamp terminals 1 cable(s) 1.5…4 mm²solid
    Screw clamp terminals 2 cable(s) 1.5…4 mm²solid
    Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end
    Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end
    Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end
    Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
    tightening torque
    1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2
    1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
    height
    58 mm
    width
    45 mm
    depth
    65 mm
    net weight
    0.145 kg
    Environment (see above)
    standards
    IEC 60947
    VDE 0660
    BS 4941
    NF C 63-650
    product certifications
    UL
    CSA
    protective treatment
    TC conforming to IEC 60068
    TC conforming to DIN 50016
    IP degree of protection
    IP2x conforming to IEC 60529
    ambient air temperature for operation
    -20…55 °C without derating conforming to IEC 60947
    -30…60 °C with derating conforming to IEC 60947
    ambient air temperature for storage
    -40…70 °C
    operating altitude
    2000 m without derating
    fire resistance
    850 °C conforming to IEC 60695-2-1
    flame retardance
    V1 conforming to UL 94
    Requirement 2 conforming to NF F 16-101
    Requirement 2 conforming to NF F 16-102
    mechanical robustness
    Shocks NO contact: 10 Gn for 11 ms conforming to IEC 60068-2-27
    Shocks NC contact: 10 Gn for 11 ms conforming to IEC 60068-2-27
    Vibrations NO contact: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
    Vibrations NC contact: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
    Packing Units (see above)
    Unit Type of Package 1
    PCE
    Number of Units in Package 1
    1
    Package 1 Weight
    158.4 g
    Package 1 Height
    5 cm
    Package 1 width
    7 cm
    Package 1 Length
    8.5 cm
    Unit Type of Package 2
    S02
    Number of Units in Package 2
    41
    Package 2 Weight
    6.892 kg
    Package 2 Height
    15 cm
    Package 2 width
    30 cm
    Package 2 Length
    40 cm
    Unit Type of Package 3
    P06
    Number of Units in Package 3
    656
    Package 3 Weight
    118.77 kg
    Package 3 Height
    77 cm
    Package 3 width
    80 cm
    Package 3 Length
    60 cm
    Offer Sustainability (see above)
    Sustainable offer status
    Green Premium product
    REACh Regulation
    REACh free of SVHC
    Yes
    EU RoHS Directive
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    China RoHS declaration
    Product out of China RoHS scope. Substance declaration for your information
    Environmental Disclosure
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    California proposition 65
    WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
    Contractual warranty (see above)
    Warranty
    12 months

    Filter By

    Product Public Price Discount Guaranteed Stock QTY Action
    Rp 2.519.344,00 100.00 % 18
    Rp 524.630,00 100.00 % Out of Stock
    Rp 1.197.823,00 100.00 % Out of Stock
    Rp 921.211,00 100.00 % 1
    Rp 435.741,00 100.00 % 2
    Rp 463.092,00 100.00 % 2
    HOT PROMO

    [Deskripsi] 1. product name : TeSys LRK 2. product or component type : Differential thermal overload relay 3. device short name : LR2K 4. relay application : Motor protection 5. product compatibility : -LP4K -LC1K -LP1K -LC7K 6. network type : -DC -AC 7. thermal overload class : Class 10A conforming to IEC 60947-4-1 8. thermal protection adjustment range : 2.6…3.7 A 9. [Ui] rated insulation voltage : -Power circuit: 690 V conforming to BS 4941 -Power circuit: 690 V conforming to IEC 60947 -Power circuit: 750 V conforming to VDE 0110 group C -Power circuit: 600 V conforming to CSA C22.2 No 14 10. network frequency : <= 400 Hz 11. mounting support : -Under contactor -Plate, with specific accessories -Rail, with specific accessories 12. auxiliary contact composition : 1 NO + 1 NC 13. [Ith] conventional free air thermal current : 6 A for signalling circuit 14. [Ue] rated operational voltage : -<= 690 V for power circuit -690 V AC AC-15 for signalling circuit -250 V DC DC-13 for signalling circuit 15. associated fuse rating : -6 A gG for signalling circuit conforming to VDE 0660 -6 A gG for signalling circuit conforming to IEC 60947 16. [Uimp] rated impulse withstand voltage : 6 kV 17. power dissipation per pole : 2 W 18. phase failure sensitivity : Yes conforming to IEC 60947-4-1 19. local signalling : Trip indicator (yellow) 20. control type : -Red push-button: trip test function -Blue push-button: stop and manual reset -selector switch: manual or automatic reset 21. connections - terminals : -Screw clamp terminals 1 cable(s) 1.5…4 mm²solid -Screw clamp terminals 2 cable(s) 1.5…4 mm²solid -Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end -Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end -Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end -Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end 22. tightening torque : -1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2 -1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm 23. height : 58 mm 24. width : 45 mm 25. depth : 65 mm 26. net weight : 0.145 kg


    Main (see above)
    range
    TeSys
    product name
    TeSys LRK
    product or component type
    Differential thermal overload relay
    device short name
    LR2K
    relay application
    Motor protection
    product compatibility
    LC7K
    LP1K
    LP4K
    LC1K
    network type
    DC
    AC
    thermal overload class
    Class 10A conforming to IEC 60947-4-1
    thermal protection adjustment range
    2.6…3.7 A
    [Ui] rated insulation voltage
    Power circuit: 690 V conforming to BS 4941
    Power circuit: 690 V conforming to IEC 60947
    Power circuit: 750 V conforming to VDE 0110 group C
    Power circuit: 600 V conforming to CSA C22.2 No 14
    Complementary (see above)
    network frequency
    <= 400 Hz
    mounting support
    Under contactor
    Plate, with specific accessories
    Rail, with specific accessories
    auxiliary contact composition
    1 NO + 1 NC
    [Ith] conventional free air thermal current
    6 A for signalling circuit
    [Ue] rated operational voltage
    <= 690 V for power circuit
    690 V AC AC-15 for signalling circuit
    250 V DC DC-13 for signalling circuit
    associated fuse rating
    6 A gG for signalling circuit conforming to VDE 0660
    6 A gG for signalling circuit conforming to IEC 60947
    [Uimp] rated impulse withstand voltage
    6 kV
    power dissipation per pole
    2 W
    phase failure sensitivity
    Yes conforming to IEC 60947-4-1
    local signalling
    Trip indicator (yellow)
    control type
    Red push-button: trip test function
    Blue push-button: stop and manual reset
    selector switch: manual or automatic reset
    connections - terminals
    Screw clamp terminals 1 cable(s) 1.5…4 mm²solid
    Screw clamp terminals 2 cable(s) 1.5…4 mm²solid
    Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end
    Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end
    Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end
    Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
    tightening torque
    1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2
    1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
    height
    58 mm
    width
    45 mm
    depth
    65 mm
    net weight
    0.145 kg
    Environment (see above)
    standards
    IEC 60947
    VDE 0660
    BS 4941
    NF C 63-650
    product certifications
    UL
    CSA
    protective treatment
    TC conforming to IEC 60068
    TC conforming to DIN 50016
    IP degree of protection
    IP2x conforming to IEC 60529
    ambient air temperature for operation
    -20…55 °C without derating conforming to IEC 60947
    -30…60 °C with derating conforming to IEC 60947
    ambient air temperature for storage
    -40…70 °C
    operating altitude
    2000 m without derating
    fire resistance
    850 °C conforming to IEC 60695-2-1
    flame retardance
    V1 conforming to UL 94
    Requirement 2 conforming to NF F 16-101
    Requirement 2 conforming to NF F 16-102
    mechanical robustness
    Shocks NO contact: 10 Gn for 11 ms conforming to IEC 60068-2-27
    Shocks NC contact: 10 Gn for 11 ms conforming to IEC 60068-2-27
    Vibrations NO contact: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
    Vibrations NC contact: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
    Packing Units (see above)
    Unit Type of Package 1
    PCE
    Number of Units in Package 1
    1
    Package 1 Weight
    158.4 g
    Package 1 Height
    5 cm
    Package 1 width
    7 cm
    Package 1 Length
    8.5 cm
    Unit Type of Package 2
    S02
    Number of Units in Package 2
    41
    Package 2 Weight
    6.892 kg
    Package 2 Height
    15 cm
    Package 2 width
    30 cm
    Package 2 Length
    40 cm
    Unit Type of Package 3
    P06
    Number of Units in Package 3
    656
    Package 3 Weight
    118.77 kg
    Package 3 Height
    77 cm
    Package 3 width
    80 cm
    Package 3 Length
    60 cm
    Offer Sustainability (see above)
    Sustainable offer status
    Green Premium product
    REACh Regulation
    REACh free of SVHC
    Yes
    EU RoHS Directive
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    China RoHS declaration
    Product out of China RoHS scope. Substance declaration for your information
    Environmental Disclosure
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    California proposition 65
    WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
    Contractual warranty (see above)
    Warranty
    12 months