    Spesifikasi
    Main (see above)
    range
    ComPact
    product name
    ComPact NSX
    range of product
    ComPact NSX100...250
    device short name
    NSX100N
    product or component type
    Circuit breaker
    device application
    Distribution
    Number of poles
    3P
    protected poles description
    3t
    [In] rated current
    16 A at 40 °C
    [Ue] rated operational voltage
    690 V AC 50/60 Hz
    network type
    AC
    network frequency
    50/60 Hz
    suitability for isolation
    Yes conforming to EN/IEC 60947-2
    utilisation category
    Category A
    [Icu] rated ultimate short-circuit breaking capacity
    85 kA at 240 V AC 50/60 Hz conforming to UL 508
    10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
    35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
    20 kA at 600 V AC 50/60 Hz conforming to UL 508
    50 kA at 480 V AC 50/60 Hz conforming to UL 508
    36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
    50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
    50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
    90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
    Performance level
    N 50 kA 415 V AC
    trip unit name
    TM-D
    trip unit technology
    Thermal-magnetic
    trip unit protection functions
    LI
    control type
    Toggle
    Circuit breaker mounting mode
    Fixed
    Complementary (see above)
    [Ui] rated insulation voltage
    800 V AC 50/60 Hz
    [Uimp] rated impulse withstand voltage
    8 kV
    [Ics] rated service short-circuit breaking capacity
    10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
    35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
    36 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
    50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
    50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
    90 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
    mechanical durability
    50000 cycles
    electrical durability
    10000 cycles at 690 V In
    20000 cycles at 690 V In/2
    30000 cycles at 440 V In
    50000 cycles at 440 V In/2
    mounting support
    Backplate
    upside connection
    Front
    downside connection
    Front
    connection pitch
    35 mm
    protection type
    L : for overload protection (thermal)
    I : for short-circuit protection (magnetic)
    trip unit rating
    16 A at 40 °C
    Long-time pick-up adjustment type Ir (thermal protection)
    Adjustable
    [Ir] long-time protection pick-up adjustment range
    0.7...1 x In
    Long-time protection delay adjustment type tr
    Fixed
    [tr] long-time protection delay adjustment range
    120…400 s at 1.5 x In
    15 s at 6 x Ir
    Short-time protection pick-up adjustment type Isd
    Fixed
    [Isd] Short-time protection pick-up adjustment range
    190 A
    Short-time protection delay adjustment type tsd
    Fixed
    earth-leakage protection
    Without
    Number of slots for electrical auxiliaries
    5 slot(s)
    Width (W)
    105 mm
    Height (H)
    161 mm
    Depth (D)
    86 mm
    net weight
    2.05 kg
    Environment (see above)
    standards
    EN/IEC 60947
    product certifications
    CCC
    EAC
    Marine
    overvoltage category
    Class II
    electrical shock protection class
    Class II
    pollution degree
    3 conforming to IEC 60664-1
    IP degree of protection
    IP40 conforming to IEC 60529
    IK degree of protection
    IK07 conforming to IEC 62262
    ambient air temperature for operation
    -25…70 °C
    ambient air temperature for storage
    -50…85 °C
    relative humidity
    0…95 %
    operating altitude
    0...2000 m without derating
    2000 m...5000 m with derating
    Packing Units (see above)
    Unit Type of Package 1
    PCE
    Number of Units in Package 1
    1
    Package 1 Weight
    1.816 kg
    Package 1 Height
    11.3 cm
    Package 1 width
    13.5 cm
    Package 1 Length
    19 cm
    Unit Type of Package 2
    S04
    Number of Units in Package 2
    12
    Package 2 Weight
    22.558 kg
    Package 2 Height
    30 cm
    Package 2 width
    40 cm
    Package 2 Length
    60 cm
    Offer Sustainability (see above)
    Sustainable offer status
    Green Premium product
    REACh Regulation
    EU RoHS Directive
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    China RoHS declaration
    Product out of China RoHS scope. Substance declaration for your information
    Environmental Disclosure
    Circularity Profile
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    Contractual warranty (see above)
    Warranty
    12 months

    Filter By

    Product Public Price Discount Guaranteed Stock QTY Action
    HOT PROMO
    Main (see above)
    range
    ComPact
    product name
    ComPact NSX
    range of product
    ComPact NSX100...250
    device short name
    NSX100N
    product or component type
    Circuit breaker
    device application
    Distribution
    Number of poles
    3P
    protected poles description
    3t
    [In] rated current
    16 A at 40 °C
    [Ue] rated operational voltage
    690 V AC 50/60 Hz
    network type
    AC
    network frequency
    50/60 Hz
    suitability for isolation
    Yes conforming to EN/IEC 60947-2
    utilisation category
    Category A
    [Icu] rated ultimate short-circuit breaking capacity
    85 kA at 240 V AC 50/60 Hz conforming to UL 508
    10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
    35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
    20 kA at 600 V AC 50/60 Hz conforming to UL 508
    50 kA at 480 V AC 50/60 Hz conforming to UL 508
    36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
    50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
    50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
    90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
    Performance level
    N 50 kA 415 V AC
    trip unit name
    TM-D
    trip unit technology
    Thermal-magnetic
    trip unit protection functions
    LI
    control type
    Toggle
    Circuit breaker mounting mode
    Fixed
    Complementary (see above)
    [Ui] rated insulation voltage
    800 V AC 50/60 Hz
    [Uimp] rated impulse withstand voltage
    8 kV
    [Ics] rated service short-circuit breaking capacity
    10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
    35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
    36 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
    50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
    50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
    90 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
    mechanical durability
    50000 cycles
    electrical durability
    10000 cycles at 690 V In
    20000 cycles at 690 V In/2
    30000 cycles at 440 V In
    50000 cycles at 440 V In/2
    mounting support
    Backplate
    upside connection
    Front
    downside connection
    Front
    connection pitch
    35 mm
    protection type
    L : for overload protection (thermal)
    I : for short-circuit protection (magnetic)
    trip unit rating
    16 A at 40 °C
    Long-time pick-up adjustment type Ir (thermal protection)
    Adjustable
    [Ir] long-time protection pick-up adjustment range
    0.7...1 x In
    Long-time protection delay adjustment type tr
    Fixed
    [tr] long-time protection delay adjustment range
    120…400 s at 1.5 x In
    15 s at 6 x Ir
    Short-time protection pick-up adjustment type Isd
    Fixed
    [Isd] Short-time protection pick-up adjustment range
    190 A
    Short-time protection delay adjustment type tsd
    Fixed
    earth-leakage protection
    Without
    Number of slots for electrical auxiliaries
    5 slot(s)
    Width (W)
    105 mm
    Height (H)
    161 mm
    Depth (D)
    86 mm
    net weight
    2.05 kg
    Environment (see above)
    standards
    EN/IEC 60947
    product certifications
    CCC
    EAC
    Marine
    overvoltage category
    Class II
    electrical shock protection class
    Class II
    pollution degree
    3 conforming to IEC 60664-1
    IP degree of protection
    IP40 conforming to IEC 60529
    IK degree of protection
    IK07 conforming to IEC 62262
    ambient air temperature for operation
    -25…70 °C
    ambient air temperature for storage
    -50…85 °C
    relative humidity
    0…95 %
    operating altitude
    0...2000 m without derating
    2000 m...5000 m with derating
    Packing Units (see above)
    Unit Type of Package 1
    PCE
    Number of Units in Package 1
    1
    Package 1 Weight
    1.816 kg
    Package 1 Height
    11.3 cm
    Package 1 width
    13.5 cm
    Package 1 Length
    19 cm
    Unit Type of Package 2
    S04
    Number of Units in Package 2
    12
    Package 2 Weight
    22.558 kg
    Package 2 Height
    30 cm
    Package 2 width
    40 cm
    Package 2 Length
    60 cm
    Offer Sustainability (see above)
    Sustainable offer status
    Green Premium product
    REACh Regulation
    EU RoHS Directive
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    China RoHS declaration
    Product out of China RoHS scope. Substance declaration for your information
    Environmental Disclosure
    Circularity Profile
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    Contractual warranty (see above)
    Warranty
    12 months