Spesifikasi
| range | ComPact | |
|---|---|---|
| product name | ComPact NSX | |
| range of product | ComPact NSX400...630 | |
| device short name | NSX400N | |
| product or component type | Circuit breaker | |
| device application | Distribution | |
| Number of poles | 4P | |
| protected poles description | 3t + N/2 3t 4t | |
| neutral position | Left | |
| [In] rated current | 400 A at 40 °C | |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz | |
| network type | AC | |
| network frequency | 50/60 Hz | |
| suitability for isolation | Yes conforming to EN/IEC 60947-2 | |
| utilisation category | Category A | |
| [Icu] rated ultimate short-circuit breaking capacity | 85 kA at 240 V AC 50/60 Hz conforming to UL 508 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 20 kA at 600 V AC 50/60 Hz conforming to UL 508 50 kA at 480 V AC 50/60 Hz conforming to UL 508 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 | |
| Performance level | N 50 kA 415 V AC | |
| trip unit name | Micrologic 2.3 | |
| trip unit technology | Electronic | |
| trip unit protection functions | LSoI | |
| control type | Toggle | |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz | |
|---|---|---|
| [Uimp] rated impulse withstand voltage | 8 kV | |
| [Ics] rated service short-circuit breaking capacity | 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 42 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 | |
| mechanical durability | 15000 cycles | |
| electrical durability | 3000 cycles at 690 V In 6000 cycles at 690 V In/2 6000 cycles at 440 V In 12000 cycles at 440 V In/2 | |
| mounting support | Backplate | |
| upside connection | Front | |
| downside connection | Front | |
| connection pitch | 45 mm | |
| protection type | L : for overload protection (long time) So : for short time short-circuit protection with fixed delay I : for instantaneous short-circuit protection | |
| trip unit rating | 400 A at 40 °C | |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable 9 settings | |
| [Ir] long-time protection pick-up adjustment range | 160...400 A | |
| Long-time protection delay adjustment type tr | Fixed | |
| [tr] long-time protection delay adjustment range | 16 s at 6 x Ir | |
| thermal memory | 20 minutes before and after tripping | |
| Short-time protection pick-up adjustment type Isd | Adjustable 9 settings | |
| [Isd] Short-time protection pick-up adjustment range | 1.5...10 x Ir | |
| Short-time protection delay adjustment type tsd | Fixed | |
| Instantaneous protection pick-up adjustment type Ii | Fixed | |
| [Ii] instantaneous protection pick-up adjustment range | 4800 A | |
| earth-leakage protection | Without | |
| Neutral protection settings | 0.5 x Ir (3t + N/2) 1 x Ir (4t) No protection (3t) | |
| Number of slots for electrical auxiliaries | 6 slot(s) | |
| local signalling | Flashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload | |
| Width (W) | 185 mm | |
| Height (H) | 255 mm | |
| Depth (D) | 110 mm | |
| net weight | 7.9 kg |
| standards | EN/IEC 60947 | |
|---|---|---|
| product certifications | CCC EAC Marine | |
| overvoltage category | Class II | |
| electrical shock protection class | Class II | |
| pollution degree | 3 conforming to IEC 60664-1 | |
| IP degree of protection | IP40 conforming to IEC 60529 | |
| IK degree of protection | IK07 conforming to IEC 62262 | |
| ambient air temperature for operation | -25…70 °C | |
| ambient air temperature for storage | -50…85 °C | |
| relative humidity | 0…95 % | |
| operating altitude | 0...2000 m without derating 2000 m...5000 m with derating |
| Unit Type of Package 1 | PCE | |
|---|---|---|
| Number of Units in Package 1 | 1 | |
| Package 1 Weight | 7.314 kg | |
| Package 1 Height | 15.082 cm | |
| Package 1 width | 20.207 cm | |
| Package 1 Length | 29.155 cm |
| Sustainable offer status | Green Premium product | |
|---|---|---|
| REACh Regulation | ||
| EU RoHS Directive | Compliant EU RoHS Declaration | |
| Mercury free | Yes | |
| RoHS exemption information | ||
| China RoHS Regulation | China RoHS declaration Product out of China RoHS scope. Substance declaration for your information | |
| Environmental Disclosure | ||
| Circularity Profile | ||
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Warranty | 12 months |
|---|
Specifications for Schneider NSX400N 4P 400A 50KA MICROLOGIC 2.3
| # of Pole | 4 |
| Arus Nominal (In) | 400A |
| range | ComPact | |
|---|---|---|
| product name | ComPact NSX | |
| range of product | ComPact NSX400...630 | |
| device short name | NSX400N | |
| product or component type | Circuit breaker | |
| device application | Distribution | |
| Number of poles | 4P | |
| protected poles description | 3t + N/2 3t 4t | |
| neutral position | Left | |
| [In] rated current | 400 A at 40 °C | |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz | |
| network type | AC | |
| network frequency | 50/60 Hz | |
| suitability for isolation | Yes conforming to EN/IEC 60947-2 | |
| utilisation category | Category A | |
| [Icu] rated ultimate short-circuit breaking capacity | 85 kA at 240 V AC 50/60 Hz conforming to UL 508 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 20 kA at 600 V AC 50/60 Hz conforming to UL 508 50 kA at 480 V AC 50/60 Hz conforming to UL 508 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 | |
| Performance level | N 50 kA 415 V AC | |
| trip unit name | Micrologic 2.3 | |
| trip unit technology | Electronic | |
| trip unit protection functions | LSoI | |
| control type | Toggle | |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz | |
|---|---|---|
| [Uimp] rated impulse withstand voltage | 8 kV | |
| [Ics] rated service short-circuit breaking capacity | 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 42 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 | |
| mechanical durability | 15000 cycles | |
| electrical durability | 3000 cycles at 690 V In 6000 cycles at 690 V In/2 6000 cycles at 440 V In 12000 cycles at 440 V In/2 | |
| mounting support | Backplate | |
| upside connection | Front | |
| downside connection | Front | |
| connection pitch | 45 mm | |
| protection type | L : for overload protection (long time) So : for short time short-circuit protection with fixed delay I : for instantaneous short-circuit protection | |
| trip unit rating | 400 A at 40 °C | |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable 9 settings | |
| [Ir] long-time protection pick-up adjustment range | 160...400 A | |
| Long-time protection delay adjustment type tr | Fixed | |
| [tr] long-time protection delay adjustment range | 16 s at 6 x Ir | |
| thermal memory | 20 minutes before and after tripping | |
| Short-time protection pick-up adjustment type Isd | Adjustable 9 settings | |
| [Isd] Short-time protection pick-up adjustment range | 1.5...10 x Ir | |
| Short-time protection delay adjustment type tsd | Fixed | |
| Instantaneous protection pick-up adjustment type Ii | Fixed | |
| [Ii] instantaneous protection pick-up adjustment range | 4800 A | |
| earth-leakage protection | Without | |
| Neutral protection settings | 0.5 x Ir (3t + N/2) 1 x Ir (4t) No protection (3t) | |
| Number of slots for electrical auxiliaries | 6 slot(s) | |
| local signalling | Flashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload | |
| Width (W) | 185 mm | |
| Height (H) | 255 mm | |
| Depth (D) | 110 mm | |
| net weight | 7.9 kg |
| standards | EN/IEC 60947 | |
|---|---|---|
| product certifications | CCC EAC Marine | |
| overvoltage category | Class II | |
| electrical shock protection class | Class II | |
| pollution degree | 3 conforming to IEC 60664-1 | |
| IP degree of protection | IP40 conforming to IEC 60529 | |
| IK degree of protection | IK07 conforming to IEC 62262 | |
| ambient air temperature for operation | -25…70 °C | |
| ambient air temperature for storage | -50…85 °C | |
| relative humidity | 0…95 % | |
| operating altitude | 0...2000 m without derating 2000 m...5000 m with derating |
| Unit Type of Package 1 | PCE | |
|---|---|---|
| Number of Units in Package 1 | 1 | |
| Package 1 Weight | 7.314 kg | |
| Package 1 Height | 15.082 cm | |
| Package 1 width | 20.207 cm | |
| Package 1 Length | 29.155 cm |
| Sustainable offer status | Green Premium product | |
|---|---|---|
| REACh Regulation | ||
| EU RoHS Directive | Compliant EU RoHS Declaration | |
| Mercury free | Yes | |
| RoHS exemption information | ||
| China RoHS Regulation | China RoHS declaration Product out of China RoHS scope. Substance declaration for your information | |
| Environmental Disclosure | ||
| Circularity Profile | ||
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Warranty | 12 months |
|---|