Spesifikasi
range | ComPact | |
---|---|---|
product name | ComPact NSX | |
range of product | ComPact NSX400...630 | |
device short name | NSX630N | |
product or component type | Circuit breaker | |
device application | Distribution | |
Number of poles | 3P | |
protected poles description | 3t | |
[In] rated current | 630 A at 40 °C | |
[Ue] rated operational voltage | 690 V AC 50/60 Hz | |
network type | AC | |
network frequency | 50/60 Hz | |
suitability for isolation | Yes conforming to EN/IEC 60947-2 | |
utilisation category | Category A | |
[Icu] rated ultimate short-circuit breaking capacity | 85 kA at 240 V AC 50/60 Hz conforming to UL 508 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 20 kA at 600 V AC 50/60 Hz conforming to UL 508 50 kA at 480 V AC 50/60 Hz conforming to UL 508 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 | |
Performance level | N 50 kA 415 V AC | |
trip unit name | Micrologic 2.3 | |
trip unit technology | Electronic | |
trip unit protection functions | LSoI | |
control type | Toggle | |
Circuit breaker mounting mode | Fixed |
[Ui] rated insulation voltage | 800 V AC 50/60 Hz | |
---|---|---|
[Uimp] rated impulse withstand voltage | 8 kV | |
[Ics] rated service short-circuit breaking capacity | 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 42 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 | |
mechanical durability | 15000 cycles | |
electrical durability | 2000 cycles at 690 V In 6000 cycles at 690 V In/2 4000 cycles at 440 V In 8000 cycles at 440 V In/2 | |
mounting support | Backplate | |
upside connection | Front | |
downside connection | Front | |
connection pitch | 45 mm | |
protection type | L : for overload protection (long time) So : for short time short-circuit protection with fixed delay I : for instantaneous short-circuit protection | |
trip unit rating | 630 A at 40 °C | |
Long-time pick-up adjustment type Ir (thermal protection) | Adjustable 9 settings | |
[Ir] long-time protection pick-up adjustment range | 250...630 A | |
Long-time protection delay adjustment type tr | Fixed | |
[tr] long-time protection delay adjustment range | 16 s at 6 x Ir | |
thermal memory | 20 minutes before and after tripping | |
Short-time protection pick-up adjustment type Isd | Adjustable 9 settings | |
[Isd] Short-time protection pick-up adjustment range | 1.5...10 x Ir | |
Short-time protection delay adjustment type tsd | Fixed | |
Instantaneous protection pick-up adjustment type Ii | Fixed | |
[Ii] instantaneous protection pick-up adjustment range | 6900 A | |
earth-leakage protection | Without | |
Number of slots for electrical auxiliaries | 6 slot(s) | |
local signalling | Flashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload | |
Width (W) | 140 mm | |
Height (H) | 255 mm | |
Depth (D) | 110 mm | |
net weight | 6.2 kg |
standards | EN/IEC 60947 | |
---|---|---|
product certifications | CCC EAC Marine | |
overvoltage category | Class II | |
electrical shock protection class | Class II | |
pollution degree | 3 conforming to IEC 60664-1 | |
IP degree of protection | IP40 conforming to IEC 60529 | |
IK degree of protection | IK07 conforming to IEC 62262 | |
ambient air temperature for operation | -25…70 °C | |
ambient air temperature for storage | -50…85 °C | |
relative humidity | 0…95 % | |
operating altitude | 0...2000 m without derating 2000 m...5000 m with derating |
Unit Type of Package 1 | PCE | |
---|---|---|
Number of Units in Package 1 | 1 | |
Package 1 Weight | 5.689 kg | |
Package 1 Height | 15.8 cm | |
Package 1 width | 16.2 cm | |
Package 1 Length | 29.4 cm | |
Unit Type of Package 2 | S04 | |
Number of Units in Package 2 | 3 | |
Package 2 Weight | 18 kg | |
Package 2 Height | 30 cm | |
Package 2 width | 40 cm | |
Package 2 Length | 60 cm | |
Unit Type of Package 3 | P12 | |
Number of Units in Package 3 | 12 | |
Package 3 Weight | 83.344 kg | |
Package 3 Height | 80 cm | |
Package 3 width | 80 cm | |
Package 3 Length | 120 cm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
EU RoHS Directive | Compliant EU RoHS Declaration | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | China RoHS declaration Product out of China RoHS scope. Substance declaration for your information | |
Environmental Disclosure | ||
Circularity Profile | ||
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Warranty | 12 months |
---|
Specifications for Schneider NSX630N 3P 630A 50KA MICROLOGIC 2.3
# of Pole | 3 |
Arus Nominal (In) | 630A |
range | ComPact | |
---|---|---|
product name | ComPact NSX | |
range of product | ComPact NSX400...630 | |
device short name | NSX630N | |
product or component type | Circuit breaker | |
device application | Distribution | |
Number of poles | 3P | |
protected poles description | 3t | |
[In] rated current | 630 A at 40 °C | |
[Ue] rated operational voltage | 690 V AC 50/60 Hz | |
network type | AC | |
network frequency | 50/60 Hz | |
suitability for isolation | Yes conforming to EN/IEC 60947-2 | |
utilisation category | Category A | |
[Icu] rated ultimate short-circuit breaking capacity | 85 kA at 240 V AC 50/60 Hz conforming to UL 508 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 20 kA at 600 V AC 50/60 Hz conforming to UL 508 50 kA at 480 V AC 50/60 Hz conforming to UL 508 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 | |
Performance level | N 50 kA 415 V AC | |
trip unit name | Micrologic 2.3 | |
trip unit technology | Electronic | |
trip unit protection functions | LSoI | |
control type | Toggle | |
Circuit breaker mounting mode | Fixed |
[Ui] rated insulation voltage | 800 V AC 50/60 Hz | |
---|---|---|
[Uimp] rated impulse withstand voltage | 8 kV | |
[Ics] rated service short-circuit breaking capacity | 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 42 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 | |
mechanical durability | 15000 cycles | |
electrical durability | 2000 cycles at 690 V In 6000 cycles at 690 V In/2 4000 cycles at 440 V In 8000 cycles at 440 V In/2 | |
mounting support | Backplate | |
upside connection | Front | |
downside connection | Front | |
connection pitch | 45 mm | |
protection type | L : for overload protection (long time) So : for short time short-circuit protection with fixed delay I : for instantaneous short-circuit protection | |
trip unit rating | 630 A at 40 °C | |
Long-time pick-up adjustment type Ir (thermal protection) | Adjustable 9 settings | |
[Ir] long-time protection pick-up adjustment range | 250...630 A | |
Long-time protection delay adjustment type tr | Fixed | |
[tr] long-time protection delay adjustment range | 16 s at 6 x Ir | |
thermal memory | 20 minutes before and after tripping | |
Short-time protection pick-up adjustment type Isd | Adjustable 9 settings | |
[Isd] Short-time protection pick-up adjustment range | 1.5...10 x Ir | |
Short-time protection delay adjustment type tsd | Fixed | |
Instantaneous protection pick-up adjustment type Ii | Fixed | |
[Ii] instantaneous protection pick-up adjustment range | 6900 A | |
earth-leakage protection | Without | |
Number of slots for electrical auxiliaries | 6 slot(s) | |
local signalling | Flashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload | |
Width (W) | 140 mm | |
Height (H) | 255 mm | |
Depth (D) | 110 mm | |
net weight | 6.2 kg |
standards | EN/IEC 60947 | |
---|---|---|
product certifications | CCC EAC Marine | |
overvoltage category | Class II | |
electrical shock protection class | Class II | |
pollution degree | 3 conforming to IEC 60664-1 | |
IP degree of protection | IP40 conforming to IEC 60529 | |
IK degree of protection | IK07 conforming to IEC 62262 | |
ambient air temperature for operation | -25…70 °C | |
ambient air temperature for storage | -50…85 °C | |
relative humidity | 0…95 % | |
operating altitude | 0...2000 m without derating 2000 m...5000 m with derating |
Unit Type of Package 1 | PCE | |
---|---|---|
Number of Units in Package 1 | 1 | |
Package 1 Weight | 5.689 kg | |
Package 1 Height | 15.8 cm | |
Package 1 width | 16.2 cm | |
Package 1 Length | 29.4 cm | |
Unit Type of Package 2 | S04 | |
Number of Units in Package 2 | 3 | |
Package 2 Weight | 18 kg | |
Package 2 Height | 30 cm | |
Package 2 width | 40 cm | |
Package 2 Length | 60 cm | |
Unit Type of Package 3 | P12 | |
Number of Units in Package 3 | 12 | |
Package 3 Weight | 83.344 kg | |
Package 3 Height | 80 cm | |
Package 3 width | 80 cm | |
Package 3 Length | 120 cm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
EU RoHS Directive | Compliant EU RoHS Declaration | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | China RoHS declaration Product out of China RoHS scope. Substance declaration for your information | |
Environmental Disclosure | ||
Circularity Profile | ||
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Warranty | 12 months |
---|