range of product | Telemecanique Limit switches XC Standard | |
---|---|---|
series name | Standard format | |
product or component type | Limit switch | |
device short name | XCKM | |
body type | Fixed | |
head type | Plunger head | |
material | Metal | |
body material | Zamak | |
fixing mode | By the body | |
movement of operating head | Linear | |
type of operator | Spring return roller plunger metal | |
type of approach | Lateral approach, 2 directions | |
cable entry | 3 entries tapped for M20 x 1.5 cable gland, cable outer diameter: 7…13 mm | |
number of poles | 2 | |
contacts type and composition | 1 NC + 1 NO | |
contact operation | Snap action |
switch actuation | By 30° cam | |
---|---|---|
electrical connection | Screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm² | |
contacts insulation form | Zb | |
number of steps | 1 | |
positive opening | With | |
positive opening minimum force | 36 N | |
minimum force for tripping | 12 N | |
minimum actuation speed | 0.01 m/min | |
maximum actuation speed | 0.5 m/s | |
contact code designation | A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 appendix A Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A | |
[Ithe] conventional enclosed thermal current | 10 A AC | |
[Ui] rated insulation voltage | 300 V conforming to UL 508 500 V (pollution degree 3) conforming to IEC 60947-1 300 V conforming to CSA C22.2 No 14 | |
maximum resistance across terminals | 25 MOhm conforming to IEC 60255-7 category 3 | |
[Uimp] rated impulse withstand voltage | 6 kV IEC 60664 6 kV IEC 60947-1 | |
short-circuit protection | 10 A cartridge fuse, type gG | |
electrical durability | 5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive load type, 24 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive load type, 48 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | |
mechanical durability | 20000000 cycles | |
width | 64 mm | |
height | 64 mm | |
depth | 30 mm | |
net weight | 0.255 kg | |
terminals description ISO n°1 | (13-14)NO (21-22)NC |
shock resistance | 50 gn for 11 ms conforming to EN/IEC 60068-2-27 | |
---|---|---|
vibration resistance | 25 gn (f= 10…500 Hz) conforming to EN/IEC 60068-2-6 | |
IP degree of protection | IP66 conforming to EN/IEC 60529 | |
IK degree of protection | IK05 conforming to EN 50102 | |
electrical shock protection class | Class I conforming to IEC 61140 Class I conforming to NF C 20-030 | |
ambient air temperature for operation | -25…70 °C | |
ambient air temperature for storage | -40…70 °C | |
protective treatment | TC | |
product certifications | CSA UL CCC | |
standards | UL 508 CSA C22.2 No 14 EN 60204-1 EN 60947-5-1 IEC 60204-1 IEC 60947-5-1 |
Unit Type of Package 1 | PCE | |
---|---|---|
Number of Units in Package 1 | 1 | |
Package 1 Weight | 271 g | |
Package 1 Height | 3.5 cm | |
Package 1 width | 6.7 cm | |
Package 1 Length | 14.7 cm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
EU RoHS Directive | Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration | |
Mercury free | Yes | |
RoHS exemption information | ||
Environmental Disclosure |
Warranty | 12 months |
---|
range of product | Telemecanique Limit switches XC Standard | |
---|---|---|
series name | Standard format | |
product or component type | Limit switch | |
device short name | XCKM | |
body type | Fixed | |
head type | Plunger head | |
material | Metal | |
body material | Zamak | |
fixing mode | By the body | |
movement of operating head | Linear | |
type of operator | Spring return roller plunger metal | |
type of approach | Lateral approach, 2 directions | |
cable entry | 3 entries tapped for M20 x 1.5 cable gland, cable outer diameter: 7…13 mm | |
number of poles | 2 | |
contacts type and composition | 1 NC + 1 NO | |
contact operation | Snap action |
switch actuation | By 30° cam | |
---|---|---|
electrical connection | Screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm² | |
contacts insulation form | Zb | |
number of steps | 1 | |
positive opening | With | |
positive opening minimum force | 36 N | |
minimum force for tripping | 12 N | |
minimum actuation speed | 0.01 m/min | |
maximum actuation speed | 0.5 m/s | |
contact code designation | A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 appendix A Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A | |
[Ithe] conventional enclosed thermal current | 10 A AC | |
[Ui] rated insulation voltage | 300 V conforming to UL 508 500 V (pollution degree 3) conforming to IEC 60947-1 300 V conforming to CSA C22.2 No 14 | |
maximum resistance across terminals | 25 MOhm conforming to IEC 60255-7 category 3 | |
[Uimp] rated impulse withstand voltage | 6 kV IEC 60664 6 kV IEC 60947-1 | |
short-circuit protection | 10 A cartridge fuse, type gG | |
electrical durability | 5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive load type, 24 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive load type, 48 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | |
mechanical durability | 20000000 cycles | |
width | 64 mm | |
height | 64 mm | |
depth | 30 mm | |
net weight | 0.255 kg | |
terminals description ISO n°1 | (13-14)NO (21-22)NC |
shock resistance | 50 gn for 11 ms conforming to EN/IEC 60068-2-27 | |
---|---|---|
vibration resistance | 25 gn (f= 10…500 Hz) conforming to EN/IEC 60068-2-6 | |
IP degree of protection | IP66 conforming to EN/IEC 60529 | |
IK degree of protection | IK05 conforming to EN 50102 | |
electrical shock protection class | Class I conforming to IEC 61140 Class I conforming to NF C 20-030 | |
ambient air temperature for operation | -25…70 °C | |
ambient air temperature for storage | -40…70 °C | |
protective treatment | TC | |
product certifications | CSA UL CCC | |
standards | UL 508 CSA C22.2 No 14 EN 60204-1 EN 60947-5-1 IEC 60204-1 IEC 60947-5-1 |
Unit Type of Package 1 | PCE | |
---|---|---|
Number of Units in Package 1 | 1 | |
Package 1 Weight | 271 g | |
Package 1 Height | 3.5 cm | |
Package 1 width | 6.7 cm | |
Package 1 Length | 14.7 cm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
EU RoHS Directive | Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration | |
Mercury free | Yes | |
RoHS exemption information | ||
Environmental Disclosure |
Warranty | 12 months |
---|