Schneider Easypact EZC Schneider Electric Easypact EZC MCCB EZC100H TMD - 40 A - 3P/3d - EZC100H3040
# of Pole : 3
Trip Unit Rating : 40 A at 50 °C
Rp 843,617.00
48.00 %
Rp 1,622,342.00
Rp 1,622,342.00
Option not available
Schneider Electric MCCB EasyPact EZC - 40 A - 3P/3d - EZC100H3040 [Deskripsi] -Aplikasi untuk instalasi listrik dengan kapasitas pemutusan rendah. -Kapasitas Pemutusan : 7.5 kA s/d 30 kA pada 380/415 VAC. -Thermal magnetic trip unit, tidak dapat disetel (non adjustable). -Fixed type, front connection. -Satu ukuran (frame size) untuk semua rating. -Memenuhi standar IEC 60947-2. -Rated @ 125V DC (1P) dan @ 250V DC (2P in series) [Spesifikasi] 1. poles description : 3P 2. protected poles description : 3t 3. network type : -DC -AC 4. network frequency : 50/60 Hz 5. [In] rated current : 100 A at 40 °C 6. [Ui] rated insulation voltage : 690 V AC 50/60 Hz conforming to IEC 60947-2 7. [Uimp] rated impulse withstand voltage : 6 kV conforming to IEC 60947-2 8. [Ue] rated operational voltage : -550 V AC 50/60 Hz conforming to IEC 60947-2 -250 V DC conforming to IEC 60947-2 9. control type : Toggle 10. mounting mode : Fixed 11. mounting support : Backplate 12. upside connection : Front 13. downside connection : Front 14. mechanical durability : 8500 cycles 15. electrical durability : Category A : 1500 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2 16. connection pitch : 25 mm 17. local signalling : Positive contact indication 18. neutral protection setting : Without protection 19. earth-leakage protection : Without 20. height : 130 mm 21. width : 75 mm 22. depth : 60 mm
Main (see above) range of product EasyPactproduct or component type Circuit breakerdevice short name Easypact EZC100Hcircuit breaker name Easypact EZC100Hdevice application Distributionpoles description 3Pprotected poles description 3tnetwork type AC
DCnetwork frequency 50/60 Hz[In] rated current 100 A at 40 °C[Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2[Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2
250 V DC conforming to IEC 60947-2breaking capacity code Hbreaking capacity 10 kA Icu at 125 V DC 1P conforming to IEC 60947-2
10 kA Icu at 250 V DC 2P conforming to IEC 60947-2
10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
30 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2
30 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2[Ics] rated service breaking capacity 15 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2
5 kA at 125 V DC conforming to IEC 60947-2
5 kA at 250 V DC conforming to IEC 60947-2
50 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2
5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2
7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2suitability for isolation Yes conforming to IEC 60947-2utilisation category Category Atrip unit name TM-Dtrip unit technology Thermal-magnetictrip unit rating 40 A at 50 °Cprotection type Overload protection
Short-circuit protectionpollution degree 3 conforming to IEC 60664-1
3 conforming to IEC 947-1Complementary (see above) control type Togglemounting mode Fixedmounting support Backplateupside connection Frontdownside connection Frontmechanical durability 8500 cycleselectrical durability Category A: 1500 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2connection pitch 25 mmlocal signalling Positive contact indicationneutral protection setting Without protectionearth-leakage protection Withoutheight 130 mmwidth 75 mmdepth 60 mmEnvironment (see above) standards JIS C8201-2-2
EN/IEC 60947-1
EN/IEC 60947-2
GB/T 14048.2IP degree of protection IP20 conforming to IEC 60529IK degree of protection IK07 conforming to IEC 62262ambient air temperature for operation -25…70 °Cambient air temperature for storage -35…85 °CPacking Units (see above) Unit Type of Package 1 PCENumber of Units in Package 1 1Package 1 Weight 790 gPackage 1 Height 9.5 cmPackage 1 width 8.5 cmPackage 1 Length 14 cmUnit Type of Package 2 S02Number of Units in Package 2 12Package 2 Weight 9.848 kgPackage 2 Height 15 cmPackage 2 width 30 cmPackage 2 Length 40 cmUnit Type of Package 3 P06Number of Units in Package 3 192Package 3 Weight 173.412 kgPackage 3 Height 80 cmPackage 3 width 80 cmPackage 3 Length 60 cmOffer Sustainability (see above) Sustainable offer status Green Premium productREACh Regulation REACh free of SVHC YesEU RoHS Directive Compliant
EU RoHS DeclarationToxic heavy metal free YesMercury free YesRoHS exemption information China RoHS Regulation Environmental Disclosure WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish binsContractual warranty (see above) Warranty 12 months
Specifications for Schneider Easypact EZC Schneider Electric Easypact EZC MCCB EZC100H TMD - 40 A - 3P/3d - EZC100H3040
# of Pole | 3 |
Trip Unit Rating | 40 A at 50 °C |
Schneider Electric MCCB EasyPact EZC - 40 A - 3P/3d - EZC100H3040 [Deskripsi] -Aplikasi untuk instalasi listrik dengan kapasitas pemutusan rendah. -Kapasitas Pemutusan : 7.5 kA s/d 30 kA pada 380/415 VAC. -Thermal magnetic trip unit, tidak dapat disetel (non adjustable). -Fixed type, front connection. -Satu ukuran (frame size) untuk semua rating. -Memenuhi standar IEC 60947-2. -Rated @ 125V DC (1P) dan @ 250V DC (2P in series) [Spesifikasi] 1. poles description : 3P 2. protected poles description : 3t 3. network type : -DC -AC 4. network frequency : 50/60 Hz 5. [In] rated current : 100 A at 40 °C 6. [Ui] rated insulation voltage : 690 V AC 50/60 Hz conforming to IEC 60947-2 7. [Uimp] rated impulse withstand voltage : 6 kV conforming to IEC 60947-2 8. [Ue] rated operational voltage : -550 V AC 50/60 Hz conforming to IEC 60947-2 -250 V DC conforming to IEC 60947-2 9. control type : Toggle 10. mounting mode : Fixed 11. mounting support : Backplate 12. upside connection : Front 13. downside connection : Front 14. mechanical durability : 8500 cycles 15. electrical durability : Category A : 1500 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2 16. connection pitch : 25 mm 17. local signalling : Positive contact indication 18. neutral protection setting : Without protection 19. earth-leakage protection : Without 20. height : 130 mm 21. width : 75 mm 22. depth : 60 mm
Main (see above) range of product EasyPactproduct or component type Circuit breakerdevice short name Easypact EZC100Hcircuit breaker name Easypact EZC100Hdevice application Distributionpoles description 3Pprotected poles description 3tnetwork type AC
DCnetwork frequency 50/60 Hz[In] rated current 100 A at 40 °C[Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2[Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2
250 V DC conforming to IEC 60947-2breaking capacity code Hbreaking capacity 10 kA Icu at 125 V DC 1P conforming to IEC 60947-2
10 kA Icu at 250 V DC 2P conforming to IEC 60947-2
10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
30 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2
30 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2[Ics] rated service breaking capacity 15 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2
5 kA at 125 V DC conforming to IEC 60947-2
5 kA at 250 V DC conforming to IEC 60947-2
50 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2
5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2
7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2suitability for isolation Yes conforming to IEC 60947-2utilisation category Category Atrip unit name TM-Dtrip unit technology Thermal-magnetictrip unit rating 40 A at 50 °Cprotection type Overload protection
Short-circuit protectionpollution degree 3 conforming to IEC 60664-1
3 conforming to IEC 947-1Complementary (see above) control type Togglemounting mode Fixedmounting support Backplateupside connection Frontdownside connection Frontmechanical durability 8500 cycleselectrical durability Category A: 1500 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2connection pitch 25 mmlocal signalling Positive contact indicationneutral protection setting Without protectionearth-leakage protection Withoutheight 130 mmwidth 75 mmdepth 60 mmEnvironment (see above) standards JIS C8201-2-2
EN/IEC 60947-1
EN/IEC 60947-2
GB/T 14048.2IP degree of protection IP20 conforming to IEC 60529IK degree of protection IK07 conforming to IEC 62262ambient air temperature for operation -25…70 °Cambient air temperature for storage -35…85 °CPacking Units (see above) Unit Type of Package 1 PCENumber of Units in Package 1 1Package 1 Weight 790 gPackage 1 Height 9.5 cmPackage 1 width 8.5 cmPackage 1 Length 14 cmUnit Type of Package 2 S02Number of Units in Package 2 12Package 2 Weight 9.848 kgPackage 2 Height 15 cmPackage 2 width 30 cmPackage 2 Length 40 cmUnit Type of Package 3 P06Number of Units in Package 3 192Package 3 Weight 173.412 kgPackage 3 Height 80 cmPackage 3 width 80 cmPackage 3 Length 60 cmOffer Sustainability (see above) Sustainable offer status Green Premium productREACh Regulation REACh free of SVHC YesEU RoHS Directive Compliant
EU RoHS DeclarationToxic heavy metal free YesMercury free YesRoHS exemption information China RoHS Regulation Environmental Disclosure WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish binsContractual warranty (see above) Warranty 12 months