Schneider Motor circuit breaker, TeSys GV2, 3P, 4 A, magnetic, rotary handle, screw clamp terminals
# of Pole : 3
Arus Pengenal (A) : 4A
Rp 615,918.00
44.00 %
Rp 1,099,854.00
Rp 1,099,854.00
Option not available
[Deskripsi] Tesys GV2 motor circuit breaker memberikan isolasi manual, pengendalian motor manual dan perlindungan thermal dan sirkuit pendek dengan panjang standar 45mm. [Spesifikasi] 1. product name : TeSys GV2 2. device short name : GV2L 3. device application : Motor 4. poles description : 3P 5. network type : AC 6. utilisation category : -Category A conforming to IEC 60947-2 -AC-3 conforming to IEC 60947-4-1 7. network frequency : 50/60 Hz conforming to IEC 60947-2 8. breaking capacity : -100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 -100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 -100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 -100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 -100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 -4 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 9. [Ics] rated service short-circuit breaking capacity -100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 -100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 -100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 -100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 -100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 10. trip unit technology : Magnetic 11. magnetic tripping current : 51 A 12. fixing mode : -Clipped on 35 mm symmetrical DIN rail -Panel: screwed (with 2 x M4 screws) 13. operating position : Any position 14. motor power kW : -3 kW at 690 V AC 50/60 Hz -1.1 kW at 400/415 V AC 50/60 Hz -1.5 kW at 400/415 V AC 50/60 Hz -1.5 kW at 500 V AC 50/60 Hz 15. control type : Rotary knob 16. [Ue] rated operational voltage : 690 V AC 50/60 Hz conforming to IEC 60947-2 17. [Ui] rated insulation voltage : 690 V AC 50/60 Hz conforming to IEC 60947-2 18. [Uimp] rated impulse withstand voltage : 6 kV conforming to IEC 60947-2 19. power dissipation per pole : 1.8 W 20. height : 89 mm 21. width : 45 mm 22. depth : 97 mm 23. net weight : 0.33 kg
range | TeSys | |
---|---|---|
product name | TeSys GV2 | |
product or component type | Circuit breaker | |
device short name | GV2L | |
device application | Motor | |
poles description | 3P | |
network type | AC | |
utilisation category | Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 | |
network frequency | 50/60 Hz conforming to IEC 60947-2 | |
breaking capacity | 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 4 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 | |
[Ics] rated service short-circuit breaking capacity | 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | |
trip unit technology | Magnetic | |
magnetic tripping current | 51 A |
fixing mode | 35 mm symmetrical DIN rail: clipped Panel: screwed (with 2 x M4 screws) | |
---|---|---|
operating position | Any position | |
motor power kW | 1.1 kW at 400/415 V AC 50/60 Hz 1.5 kW at 400/415 V AC 50/60 Hz 1.5 kW at 500 V AC 50/60 Hz 3 kW at 690 V AC 50/60 Hz | |
control type | Rotary knob | |
[Ue] rated operational voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 | |
[Ui] rated insulation voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 | |
[Uimp] rated impulse withstand voltage | IEC 60947-2 6 kV | |
power dissipation per pole | 1.8 W | |
mechanical durability | 100000 cycles | |
electrical durability | 100000 cycles for AC-3 at 415 V | |
maximum operating rate | 40 cyc/h | |
rated duty | Continuous conforming to IEC 60947-4-1 | |
connections - terminals | Screw clamp terminals 2 cable(s) 1…6 mm² solid Screw clamp terminals 2 cable(s) 1.5…6 mm² flexible without cable end Screw clamp terminals 2 cable(s) 1…4 mm² flexible with cable end | |
tightening torque | 1.7 N.m on screw clamp terminals | |
mechanical robustness | Shocks: 30 Gn conforming to IEC 60068-2-27 Vibrations: 5 Gn, 5...150 Hz conforming to IEC 60068-2-6 | |
suitability for isolation | Yes conforming to IEC 60947-1 | |
height | 89 mm | |
width | 45 mm | |
depth | 97 mm | |
net weight | 0.33 kg |
standards | EN/IEC 60947-2 EN/IEC 60947-4-1 CSA C22.2 No 60947-4-1 UL 60947-4-1 | |
---|---|---|
product certifications | IECEE CB Scheme UL CSA CCC EAC RINA LROS (Lloyds register of shipping) DNV-GL BV | |
protective treatment | TH | |
IP degree of protection | IP20 conforming to IEC 60529 | |
IK degree of protection | IK04 | |
ambient air temperature for operation | -20…60 °C | |
ambient air temperature for storage | -40…80 °C | |
fire resistance | 960 °C conforming to IEC 60695-2-1 | |
operating altitude | 0...2000 m |
Unit Type of Package 1 | PCE | |
---|---|---|
Number of Units in Package 1 | 1 | |
Package 1 Weight | 324 g | |
Package 1 Height | 5 cm | |
Package 1 width | 9 cm | |
Package 1 Length | 10 cm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
EU RoHS Directive | Compliant EU RoHS Declaration | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | China RoHS declaration Product out of China RoHS scope. Substance declaration for your information | |
Environmental Disclosure | ||
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | |
California proposition 65 | WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov |
Warranty | 12 months |
---|
Specifications for Schneider Motor circuit breaker, TeSys GV2, 3P, 4 A, magnetic, rotary handle, screw clamp terminals
# of Pole | 3 |
Arus Pengenal (A) | 4A |
[Deskripsi] Tesys GV2 motor circuit breaker memberikan isolasi manual, pengendalian motor manual dan perlindungan thermal dan sirkuit pendek dengan panjang standar 45mm. [Spesifikasi] 1. product name : TeSys GV2 2. device short name : GV2L 3. device application : Motor 4. poles description : 3P 5. network type : AC 6. utilisation category : -Category A conforming to IEC 60947-2 -AC-3 conforming to IEC 60947-4-1 7. network frequency : 50/60 Hz conforming to IEC 60947-2 8. breaking capacity : -100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 -100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 -100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 -100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 -100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 -4 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 9. [Ics] rated service short-circuit breaking capacity -100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 -100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 -100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 -100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 -100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 10. trip unit technology : Magnetic 11. magnetic tripping current : 51 A 12. fixing mode : -Clipped on 35 mm symmetrical DIN rail -Panel: screwed (with 2 x M4 screws) 13. operating position : Any position 14. motor power kW : -3 kW at 690 V AC 50/60 Hz -1.1 kW at 400/415 V AC 50/60 Hz -1.5 kW at 400/415 V AC 50/60 Hz -1.5 kW at 500 V AC 50/60 Hz 15. control type : Rotary knob 16. [Ue] rated operational voltage : 690 V AC 50/60 Hz conforming to IEC 60947-2 17. [Ui] rated insulation voltage : 690 V AC 50/60 Hz conforming to IEC 60947-2 18. [Uimp] rated impulse withstand voltage : 6 kV conforming to IEC 60947-2 19. power dissipation per pole : 1.8 W 20. height : 89 mm 21. width : 45 mm 22. depth : 97 mm 23. net weight : 0.33 kg
range | TeSys | |
---|---|---|
product name | TeSys GV2 | |
product or component type | Circuit breaker | |
device short name | GV2L | |
device application | Motor | |
poles description | 3P | |
network type | AC | |
utilisation category | Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 | |
network frequency | 50/60 Hz conforming to IEC 60947-2 | |
breaking capacity | 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 4 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 | |
[Ics] rated service short-circuit breaking capacity | 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | |
trip unit technology | Magnetic | |
magnetic tripping current | 51 A |
fixing mode | 35 mm symmetrical DIN rail: clipped Panel: screwed (with 2 x M4 screws) | |
---|---|---|
operating position | Any position | |
motor power kW | 1.1 kW at 400/415 V AC 50/60 Hz 1.5 kW at 400/415 V AC 50/60 Hz 1.5 kW at 500 V AC 50/60 Hz 3 kW at 690 V AC 50/60 Hz | |
control type | Rotary knob | |
[Ue] rated operational voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 | |
[Ui] rated insulation voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 | |
[Uimp] rated impulse withstand voltage | IEC 60947-2 6 kV | |
power dissipation per pole | 1.8 W | |
mechanical durability | 100000 cycles | |
electrical durability | 100000 cycles for AC-3 at 415 V | |
maximum operating rate | 40 cyc/h | |
rated duty | Continuous conforming to IEC 60947-4-1 | |
connections - terminals | Screw clamp terminals 2 cable(s) 1…6 mm² solid Screw clamp terminals 2 cable(s) 1.5…6 mm² flexible without cable end Screw clamp terminals 2 cable(s) 1…4 mm² flexible with cable end | |
tightening torque | 1.7 N.m on screw clamp terminals | |
mechanical robustness | Shocks: 30 Gn conforming to IEC 60068-2-27 Vibrations: 5 Gn, 5...150 Hz conforming to IEC 60068-2-6 | |
suitability for isolation | Yes conforming to IEC 60947-1 | |
height | 89 mm | |
width | 45 mm | |
depth | 97 mm | |
net weight | 0.33 kg |
standards | EN/IEC 60947-2 EN/IEC 60947-4-1 CSA C22.2 No 60947-4-1 UL 60947-4-1 | |
---|---|---|
product certifications | IECEE CB Scheme UL CSA CCC EAC RINA LROS (Lloyds register of shipping) DNV-GL BV | |
protective treatment | TH | |
IP degree of protection | IP20 conforming to IEC 60529 | |
IK degree of protection | IK04 | |
ambient air temperature for operation | -20…60 °C | |
ambient air temperature for storage | -40…80 °C | |
fire resistance | 960 °C conforming to IEC 60695-2-1 | |
operating altitude | 0...2000 m |
Unit Type of Package 1 | PCE | |
---|---|---|
Number of Units in Package 1 | 1 | |
Package 1 Weight | 324 g | |
Package 1 Height | 5 cm | |
Package 1 width | 9 cm | |
Package 1 Length | 10 cm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
EU RoHS Directive | Compliant EU RoHS Declaration | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | China RoHS declaration Product out of China RoHS scope. Substance declaration for your information | |
Environmental Disclosure | ||
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | |
California proposition 65 | WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov |
Warranty | 12 months |
---|