Spesifikasi
| range | TeSys | |
|---|---|---|
| product name | TeSys D | |
| product or component type | Auxiliary contact block | |
| range compatibility | TeSys D LC1D TeSys D CAD | |
| mounting location | Side | |
| pole contact composition | 2 NC | |
| Contacts operation | Instantaneous | |
| [Ue] rated operational voltage | 690 V AC 25...400 Hz | |
| [Ie] rated operational current | 6 A at 120 V AC-15 1.04 A at 690 V AC-15 0.55 A at 125 V DC-13 0.1 A at 600 V DC-13 | |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-5-1 600 V conforming to UL 60947-5-1 600 V conforming to CSA C22.2 No 60947-5-1 | |
| [Ith] conventional free air thermal current | 10 A (at 60 °C) | |
| standards | EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 | |
| product certifications | IECEE CB Scheme UL CSA CCC EAC |
| Irms rated making capacity | 140 A AC conforming to IEC 60947-5-1 250 A DC conforming to IEC 60947-5-1 | |
|---|---|---|
| permissible short-time rating | 100 A 60 °C 1 s 120 A 60 °C 500 ms 140 A 60 °C 100 ms | |
| protection type | GG fuse 10 A | |
| mechanical durability | 30 Mcycles | |
| minimum switching current | 5 mA | |
| minimum switching voltage | 17 V | |
| non-overlap time | 1.5 ms on de-energisation no overlap between NC and NO contact 1.5 ms on energisation no overlap between NC and NO contact | |
| insulation resistance | > 10 MOhm | |
| connections - terminals | Screw clamp terminals 1 cable(s) 1…2.5 mm²flexible with cable end Screw clamp terminals 1 cable(s) 1…2.5 mm²flexible without cable end Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible without cable end Screw clamp terminals 1 cable(s) 1…2.5 mm²rigid Screw clamp terminals 2 cable(s) 1…2.5 mm²rigid | |
| tightening torque | 1.7 N.m - with screwdriver flat Ø 6 mm 1.7 N.m - with screwdriver Philips No 2 | |
| height | 76 mm | |
| width | 12.5 mm | |
| depth | 76 mm |
| environmental characteristic | Normal environment | |
|---|---|---|
| IP degree of protection | IP20 conforming to IEC 60529 | |
| protective treatment | TH conforming to IEC 60068 | |
| ambient air temperature for storage | -60…80 °C | |
| ambient air temperature for operation | -5…60 °C | |
| operating altitude | 3000 m |
| Unit Type of Package 1 | PCE | |
|---|---|---|
| Number of Units in Package 1 | 1 | |
| Package 1 Weight | 60 g | |
| Package 1 Height | 8 cm | |
| Package 1 width | 3 cm | |
| Package 1 Length | 7.3 cm |
| Sustainable offer status | Green Premium product | |
|---|---|---|
| REACh Regulation | ||
| REACh free of SVHC | Yes | |
| EU RoHS Directive | Compliant EU RoHS Declaration | |
| Toxic heavy metal free | Yes | |
| Mercury free | Yes | |
| RoHS exemption information | ||
| China RoHS Regulation | China RoHS declaration Pro-active China RoHS declaration (out of China RoHS legal scope) | |
| Environmental Disclosure | ||
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | |
| California proposition 65 | WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov |
| range | TeSys | |
|---|---|---|
| product name | TeSys D | |
| product or component type | Auxiliary contact block | |
| range compatibility | TeSys D LC1D TeSys D CAD | |
| mounting location | Side | |
| pole contact composition | 2 NC | |
| Contacts operation | Instantaneous | |
| [Ue] rated operational voltage | 690 V AC 25...400 Hz | |
| [Ie] rated operational current | 6 A at 120 V AC-15 1.04 A at 690 V AC-15 0.55 A at 125 V DC-13 0.1 A at 600 V DC-13 | |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-5-1 600 V conforming to UL 60947-5-1 600 V conforming to CSA C22.2 No 60947-5-1 | |
| [Ith] conventional free air thermal current | 10 A (at 60 °C) | |
| standards | EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 | |
| product certifications | IECEE CB Scheme UL CSA CCC EAC |
| Irms rated making capacity | 140 A AC conforming to IEC 60947-5-1 250 A DC conforming to IEC 60947-5-1 | |
|---|---|---|
| permissible short-time rating | 100 A 60 °C 1 s 120 A 60 °C 500 ms 140 A 60 °C 100 ms | |
| protection type | GG fuse 10 A | |
| mechanical durability | 30 Mcycles | |
| minimum switching current | 5 mA | |
| minimum switching voltage | 17 V | |
| non-overlap time | 1.5 ms on de-energisation no overlap between NC and NO contact 1.5 ms on energisation no overlap between NC and NO contact | |
| insulation resistance | > 10 MOhm | |
| connections - terminals | Screw clamp terminals 1 cable(s) 1…2.5 mm²flexible with cable end Screw clamp terminals 1 cable(s) 1…2.5 mm²flexible without cable end Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible without cable end Screw clamp terminals 1 cable(s) 1…2.5 mm²rigid Screw clamp terminals 2 cable(s) 1…2.5 mm²rigid | |
| tightening torque | 1.7 N.m - with screwdriver flat Ø 6 mm 1.7 N.m - with screwdriver Philips No 2 | |
| height | 76 mm | |
| width | 12.5 mm | |
| depth | 76 mm |
| environmental characteristic | Normal environment | |
|---|---|---|
| IP degree of protection | IP20 conforming to IEC 60529 | |
| protective treatment | TH conforming to IEC 60068 | |
| ambient air temperature for storage | -60…80 °C | |
| ambient air temperature for operation | -5…60 °C | |
| operating altitude | 3000 m |
| Unit Type of Package 1 | PCE | |
|---|---|---|
| Number of Units in Package 1 | 1 | |
| Package 1 Weight | 60 g | |
| Package 1 Height | 8 cm | |
| Package 1 width | 3 cm | |
| Package 1 Length | 7.3 cm |
| Sustainable offer status | Green Premium product | |
|---|---|---|
| REACh Regulation | ||
| REACh free of SVHC | Yes | |
| EU RoHS Directive | Compliant EU RoHS Declaration | |
| Toxic heavy metal free | Yes | |
| Mercury free | Yes | |
| RoHS exemption information | ||
| China RoHS Regulation | China RoHS declaration Pro-active China RoHS declaration (out of China RoHS legal scope) | |
| Environmental Disclosure | ||
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | |
| California proposition 65 | WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov |