Schneider TeSys F contactor - 3P(3 NO) - AC-3 - <= 440 V 630 A - without coil
# of Pole : 3
Rp 25,294,654.00
55.00 %
Rp 56,210,344.00
Rp 56,210,344.00
Option not available
[Deskripsi] 1. product name : TeSys F 2. product or component type : Contactor 3. device short name : LC1F 4. contactor application : -Resistive load -Motor control 5. utilisation category : -AC-1 -AC-4 -AC-3 6. poles description : 3P 7. power pole contact composition : 3 NO 8. [Ue] rated operational voltage : -<= 1000 V AC 50/60 Hz -<= 460 V DC 9. [Ie] rated operational current : -1000 A (at <40 °C) at <= 440 V AC-1 -630 A (at <55 °C) at <= 440 V AC-3 10. motor power kW : -335 kW at 380...400 V AC 50/60 Hz (AC-3) -375 kW at 415 V AC 50/60 Hz (AC-3) -400 kW at 440 V AC 50/60 Hz (AC-3) -400 kW at 500 V AC 50/60 Hz (AC-3) -450 kW at 1000 V AC 50/60 Hz (AC-3) -200 kW at 220...240 V AC 50/60 Hz (AC-3) -450 kW at 660...690 V AC 50/60 Hz (AC-3) -100 kW at 400 V AC 50/60 Hz (AC-4) 11. [Uimp] rated impulse withstand voltage : 8 kV 12. overvoltage category : III 13. [Ith] conventional free air thermal current : -1000 A (at 40 °C) -1250 A 14. Irms rated making capacity : 6300 A conforming to IEC 60947-4-1 15. rated breaking capacity : 5040 A conforming to IEC 60947-4-1 16. [Icw] rated short-time withstand current : -5050 A 40 °C - 10 s -4400 A 40 °C - 30 s -3400 A 40 °C - 1 min -2200 A 40 °C - 3 min -1600 A 40 °C - 10 min 17. associated fuse rating : -630 A aM at <= 440 V -2000 A gG at <= 440 V 18. average impedance : 0.12 mOhm - Ith 1000 A 50 Hz 19. [Ui] rated insulation voltage : -1000 V conforming to IEC 60947-4-1 -1500 V conforming to VDE 0110 group C 20. power dissipation per pole : -120 W AC-1 -48 W AC-3 21. mounting support : Plate 22. standards : -EN 60947-1 -JIS C8201-4-1 -IEC 60947-4-1 -EN 60947-4-1 -IEC 60947-1 23. product certifications : -RINA -ABS -CSA -DNV -RMRoS -BV -LROS (Lloyds register of shipping) -UL -CB 24. connections - terminals : -Power circuit: lugs-ring terminals 1 cable(s) 95 mm² -Power circuit: connector 1 cable(s) 95 mm² -Power circuit: bar 2 cable(s) - busbar cross section: 20 x 3 mm -Power circuit: bolted connection 25. tightening torque : Power circuit: 18 N.m 26. IP degree of protection : -IP2x front face with shrouds conforming to IEC 60529 -IP2x front face with shrouds conforming to VDE 0106 27. protective treatment : TH 28. ambient air temperature for operation : -5…55 °C 29. ambient air temperature for storage : -60…80 °C 30. permissible ambient air temperature around the device : -40…70 °C 31. operating altitude : 3000 m without 32. mechanical robustness : -Vibrations contactor open: 2 Gn, 5...300 Hz -Vibrations contactor closed: 6 Gn, 5...300 Hz -Shocks contactor open: 9 Gn for 1/2 sine wave (11 ms) -Shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms) 33. height : 304 mm 34. width : 309 mm 35. depth : 255 mm 36. net weight : 18.6 kg
range | TeSys | |
---|---|---|
product name | TeSys F | |
product or component type | Contactor | |
device short name | LC1F | |
contactor application | Resistive load Motor control | |
utilisation category | AC-4 AC-1 AC-3 | |
poles description | 3P | |
power pole contact composition | 3 NO | |
[Ue] rated operational voltage | <= 1000 V AC 50/60 Hz <= 460 V DC | |
[Ie] rated operational current | 1000 A (at <40 °C) at <= 440 V AC AC-1 630 A (at <55 °C) at <= 440 V AC AC-3 | |
motor power kW | 335 kW at 380...400 V AC 50/60 Hz (AC-3) 375 kW at 415 V AC 50/60 Hz (AC-3) 400 kW at 440 V AC 50/60 Hz (AC-3) 400 kW at 500 V AC 50/60 Hz (AC-3) 450 kW at 1000 V AC 50/60 Hz (AC-3) 200 kW at 220...240 V AC 50/60 Hz (AC-3) 450 kW at 660...690 V AC 50/60 Hz (AC-3) 100 kW at 400 V AC 50/60 Hz (AC-4) |
[Uc] control circuit voltage | 48...1000 V AC 40...400 Hz with LX1/LX9 coil 48...440 V DC with LX4 coil | |
---|---|---|
[Uimp] rated impulse withstand voltage | 8 kV | |
overvoltage category | III | |
[Ith] conventional free air thermal current | 1000 A (at 40 °C) 1250 A | |
Irms rated making capacity | 6300 A AC conforming to IEC 60947-4-1 | |
rated breaking capacity | 5040 A conforming to IEC 60947-4-1 | |
[Icw] rated short-time withstand current | 5050 A 40 °C - 10 s 4400 A 40 °C - 30 s 3400 A 40 °C - 1 min 2200 A 40 °C - 3 min 1600 A 40 °C - 10 min | |
associated fuse rating | 630 A aM at <= 440 V 1000 A gG at <= 440 V | |
average impedance | 0.12 mOhm - Ith 1000 A 50 Hz | |
[Ui] rated insulation voltage | 1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C | |
power dissipation per pole | 120 W AC-1 48 W AC-3 | |
control circuit voltage limits | Operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coil Drop-out: 0.25...0.5 Uc AC 40...400 Hz with LX1/LX9 coil Operational: 0.85...1.1 Uc DC with LX4 coil Drop-out: 0.2...0.35 Uc DC with LX4 coil | |
heat dissipation | 20 W | |
operating time | 40...80 ms closing for with LX1/LX9 coil 100...200 ms opening for with LX1/LX9 coil 60...70 ms closing for with LX4 coil 40...50 ms opening for with LX4 coil | |
mounting support | Plate | |
standards | EN 60947-4-1 IEC 60947-4-1 IEC 60947-1 JIS C8201-4-1 EN 60947-1 | |
product certifications | ABS UL RINA DNV CSA CB LROS (Lloyds register of shipping) BV RMRoS UKCA | |
connections - terminals | Power circuit: bar 2 cable(s) - busbar cross section: 60 x 5 mm Power circuit: bolted connection Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²solid without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm² Control circuit: screw clamp terminals 2 cable(s) 1…4 mm² | |
tightening torque | Power circuit: 58 N.m Control circuit: 1.2 N.m | |
mechanical durability | 5 Mcycles | |
inrush power in VA | 1500…1730 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil 1420…1920 VA (at 20 °C)with LX4 coil | |
hold-in power consumption in VA | 20…25 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil 6.5…12.5 VA (at 20 °C)with LX4 coil | |
maximum operating rate | 1200 cyc/h 55 °C | |
compatibility code | LC1F |
IP degree of protection | IP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106 | |
---|---|---|
protective treatment | TH | |
ambient air temperature for operation | -5…55 °C | |
ambient air temperature for storage | -60…80 °C | |
permissible ambient air temperature around the device | -40…70 °C | |
operating altitude | 3000 m without derating | |
mechanical robustness | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor open: 6 Gn for 1/2 sine wave (11 ms) Shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms) | |
height | 304 mm | |
width | 309 mm | |
depth | 255 mm | |
net weight | 18.6 kg |
Unit Type of Package 1 | PCE | |
---|---|---|
Number of Units in Package 1 | 1 | |
Package 1 Weight | 17.11 kg | |
Package 1 Height | 34 cm | |
Package 1 width | 34 cm | |
Package 1 Length | 45 cm | |
Unit Type of Package 2 | P06 | |
Number of Units in Package 2 | 4 | |
Package 2 Weight | 76.94 kg | |
Package 2 Height | 80 cm | |
Package 2 width | 80 cm | |
Package 2 Length | 60 cm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
EU RoHS Directive | Compliant EU RoHS Declaration | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | China RoHS declaration Product out of China RoHS scope. Substance declaration for your information | |
Environmental Disclosure | ||
Circularity Profile | ||
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Warranty | 12 months |
---|
Specifications for Schneider TeSys F contactor - 3P(3 NO) - AC-3 - <= 440 V 630 A - without coil
# of Pole | 3 |
[Deskripsi] 1. product name : TeSys F 2. product or component type : Contactor 3. device short name : LC1F 4. contactor application : -Resistive load -Motor control 5. utilisation category : -AC-1 -AC-4 -AC-3 6. poles description : 3P 7. power pole contact composition : 3 NO 8. [Ue] rated operational voltage : -<= 1000 V AC 50/60 Hz -<= 460 V DC 9. [Ie] rated operational current : -1000 A (at <40 °C) at <= 440 V AC-1 -630 A (at <55 °C) at <= 440 V AC-3 10. motor power kW : -335 kW at 380...400 V AC 50/60 Hz (AC-3) -375 kW at 415 V AC 50/60 Hz (AC-3) -400 kW at 440 V AC 50/60 Hz (AC-3) -400 kW at 500 V AC 50/60 Hz (AC-3) -450 kW at 1000 V AC 50/60 Hz (AC-3) -200 kW at 220...240 V AC 50/60 Hz (AC-3) -450 kW at 660...690 V AC 50/60 Hz (AC-3) -100 kW at 400 V AC 50/60 Hz (AC-4) 11. [Uimp] rated impulse withstand voltage : 8 kV 12. overvoltage category : III 13. [Ith] conventional free air thermal current : -1000 A (at 40 °C) -1250 A 14. Irms rated making capacity : 6300 A conforming to IEC 60947-4-1 15. rated breaking capacity : 5040 A conforming to IEC 60947-4-1 16. [Icw] rated short-time withstand current : -5050 A 40 °C - 10 s -4400 A 40 °C - 30 s -3400 A 40 °C - 1 min -2200 A 40 °C - 3 min -1600 A 40 °C - 10 min 17. associated fuse rating : -630 A aM at <= 440 V -2000 A gG at <= 440 V 18. average impedance : 0.12 mOhm - Ith 1000 A 50 Hz 19. [Ui] rated insulation voltage : -1000 V conforming to IEC 60947-4-1 -1500 V conforming to VDE 0110 group C 20. power dissipation per pole : -120 W AC-1 -48 W AC-3 21. mounting support : Plate 22. standards : -EN 60947-1 -JIS C8201-4-1 -IEC 60947-4-1 -EN 60947-4-1 -IEC 60947-1 23. product certifications : -RINA -ABS -CSA -DNV -RMRoS -BV -LROS (Lloyds register of shipping) -UL -CB 24. connections - terminals : -Power circuit: lugs-ring terminals 1 cable(s) 95 mm² -Power circuit: connector 1 cable(s) 95 mm² -Power circuit: bar 2 cable(s) - busbar cross section: 20 x 3 mm -Power circuit: bolted connection 25. tightening torque : Power circuit: 18 N.m 26. IP degree of protection : -IP2x front face with shrouds conforming to IEC 60529 -IP2x front face with shrouds conforming to VDE 0106 27. protective treatment : TH 28. ambient air temperature for operation : -5…55 °C 29. ambient air temperature for storage : -60…80 °C 30. permissible ambient air temperature around the device : -40…70 °C 31. operating altitude : 3000 m without 32. mechanical robustness : -Vibrations contactor open: 2 Gn, 5...300 Hz -Vibrations contactor closed: 6 Gn, 5...300 Hz -Shocks contactor open: 9 Gn for 1/2 sine wave (11 ms) -Shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms) 33. height : 304 mm 34. width : 309 mm 35. depth : 255 mm 36. net weight : 18.6 kg
range | TeSys | |
---|---|---|
product name | TeSys F | |
product or component type | Contactor | |
device short name | LC1F | |
contactor application | Resistive load Motor control | |
utilisation category | AC-4 AC-1 AC-3 | |
poles description | 3P | |
power pole contact composition | 3 NO | |
[Ue] rated operational voltage | <= 1000 V AC 50/60 Hz <= 460 V DC | |
[Ie] rated operational current | 1000 A (at <40 °C) at <= 440 V AC AC-1 630 A (at <55 °C) at <= 440 V AC AC-3 | |
motor power kW | 335 kW at 380...400 V AC 50/60 Hz (AC-3) 375 kW at 415 V AC 50/60 Hz (AC-3) 400 kW at 440 V AC 50/60 Hz (AC-3) 400 kW at 500 V AC 50/60 Hz (AC-3) 450 kW at 1000 V AC 50/60 Hz (AC-3) 200 kW at 220...240 V AC 50/60 Hz (AC-3) 450 kW at 660...690 V AC 50/60 Hz (AC-3) 100 kW at 400 V AC 50/60 Hz (AC-4) |
[Uc] control circuit voltage | 48...1000 V AC 40...400 Hz with LX1/LX9 coil 48...440 V DC with LX4 coil | |
---|---|---|
[Uimp] rated impulse withstand voltage | 8 kV | |
overvoltage category | III | |
[Ith] conventional free air thermal current | 1000 A (at 40 °C) 1250 A | |
Irms rated making capacity | 6300 A AC conforming to IEC 60947-4-1 | |
rated breaking capacity | 5040 A conforming to IEC 60947-4-1 | |
[Icw] rated short-time withstand current | 5050 A 40 °C - 10 s 4400 A 40 °C - 30 s 3400 A 40 °C - 1 min 2200 A 40 °C - 3 min 1600 A 40 °C - 10 min | |
associated fuse rating | 630 A aM at <= 440 V 1000 A gG at <= 440 V | |
average impedance | 0.12 mOhm - Ith 1000 A 50 Hz | |
[Ui] rated insulation voltage | 1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C | |
power dissipation per pole | 120 W AC-1 48 W AC-3 | |
control circuit voltage limits | Operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coil Drop-out: 0.25...0.5 Uc AC 40...400 Hz with LX1/LX9 coil Operational: 0.85...1.1 Uc DC with LX4 coil Drop-out: 0.2...0.35 Uc DC with LX4 coil | |
heat dissipation | 20 W | |
operating time | 40...80 ms closing for with LX1/LX9 coil 100...200 ms opening for with LX1/LX9 coil 60...70 ms closing for with LX4 coil 40...50 ms opening for with LX4 coil | |
mounting support | Plate | |
standards | EN 60947-4-1 IEC 60947-4-1 IEC 60947-1 JIS C8201-4-1 EN 60947-1 | |
product certifications | ABS UL RINA DNV CSA CB LROS (Lloyds register of shipping) BV RMRoS UKCA | |
connections - terminals | Power circuit: bar 2 cable(s) - busbar cross section: 60 x 5 mm Power circuit: bolted connection Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²solid without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm² Control circuit: screw clamp terminals 2 cable(s) 1…4 mm² | |
tightening torque | Power circuit: 58 N.m Control circuit: 1.2 N.m | |
mechanical durability | 5 Mcycles | |
inrush power in VA | 1500…1730 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil 1420…1920 VA (at 20 °C)with LX4 coil | |
hold-in power consumption in VA | 20…25 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil 6.5…12.5 VA (at 20 °C)with LX4 coil | |
maximum operating rate | 1200 cyc/h 55 °C | |
compatibility code | LC1F |
IP degree of protection | IP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106 | |
---|---|---|
protective treatment | TH | |
ambient air temperature for operation | -5…55 °C | |
ambient air temperature for storage | -60…80 °C | |
permissible ambient air temperature around the device | -40…70 °C | |
operating altitude | 3000 m without derating | |
mechanical robustness | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor open: 6 Gn for 1/2 sine wave (11 ms) Shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms) | |
height | 304 mm | |
width | 309 mm | |
depth | 255 mm | |
net weight | 18.6 kg |
Unit Type of Package 1 | PCE | |
---|---|---|
Number of Units in Package 1 | 1 | |
Package 1 Weight | 17.11 kg | |
Package 1 Height | 34 cm | |
Package 1 width | 34 cm | |
Package 1 Length | 45 cm | |
Unit Type of Package 2 | P06 | |
Number of Units in Package 2 | 4 | |
Package 2 Weight | 76.94 kg | |
Package 2 Height | 80 cm | |
Package 2 width | 80 cm | |
Package 2 Length | 60 cm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
EU RoHS Directive | Compliant EU RoHS Declaration | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | China RoHS declaration Product out of China RoHS scope. Substance declaration for your information | |
Environmental Disclosure | ||
Circularity Profile | ||
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Warranty | 12 months |
---|