• Sign up now and get discount up to 47%

Schneider CONTACTOR 600VAC 50AMP IEC +OPTIONS

Arus Pengenal (A) : 50A

Coil DC : 24V (BD)

Rp 0.00 Rp 0.00 0 IDR

Rp 0.00

Option not available

  • Arus Pengenal (A)
  • Coil DC

This combination does not exist.

Add to Cart

Schneider CONTACTOR 600VAC 50AMP IEC +OPTIONS
Terjual 0
0 (0 Rating)
Ulasan (0)

Rp 0.00
0.00 % Rp 0.00 0 IDR

Rp 0.00

Option not available

Atur Jumlah & Catatan
Stock Total: Out of Stock

Arus Pengenal (A) : 50A

Coil DC : 24V (BD)

Spesifikasi
Main (see above)
range of product
TeSys D
range
TeSys
product or component type
Contactor
device short name
LC1D
contactor application
Motor control
Resistive load
utilisation category
AC-1
AC-2
AC-4
AC-3
control circuit type
DC standard
poles description
3P
pole contact composition
3 NO
[Ie] rated operational current
50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
motor power kW
22 kW at 380...400 V AC 50 Hz (AC-3)
25 kW at 415 V AC 50 Hz (AC-3)
30 kW at 440 V AC 50 Hz (AC-3)
30 kW at 500 V AC 50 Hz (AC-3)
33 kW at 660...690 V AC 50 Hz (AC-3)
15 kW at 220...230 V AC 50 Hz (AC-3)
11 kW at 400 V AC 50 Hz (AC-4)
30 kW at 1000 V AC 50 Hz (AC-3)
Complementary (see above)
coil technology
Built-in bidirectional peak limiting diode suppressor
Front cover
With
motor power hp
3 hp at 115 V AC 60 Hz for 1 phase motors
7.5 hp at 230/240 V AC 60 Hz for 1 phase motors
15 hp at 200/208 V AC 60 Hz for 3 phases motors
15 hp at 230/240 V AC 60 Hz for 3 phases motors
40 hp at 460/480 V AC 60 Hz for 3 phases motors
40 hp at 575/600 V AC 60 Hz for 3 phases motors
auxiliary contacts type
type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
auxiliary contact composition
1 NO + 1 NC
[Uc] control circuit voltage
24 V DC
control circuit voltage limits
0.1...0.3 Uc (-40…70 °C):drop-out DC
0.75...1.25 Uc (-40…60 °C):operational DC
1...1.25 Uc (60…70 °C):operational DC
time constant
34 ms
[Ui] rated insulation voltage
Control circuit: 600 V CSA certified
Control circuit: 600 V UL certified
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Control circuit: 690 V conforming to IEC 60947-1
Power circuit: 690 V conforming to IEC 60947-1
Power circuit: 1000 V conforming to IEC 60947-4-1
[Uimp] rated impulse withstand voltage
8 kV conforming to IEC 60947
overvoltage category
III
mounting support
Rail
Plate
flame retardance
V1 conforming to UL 94
connections - terminals
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²rigid
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²rigid
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Power circuit: screw terminals 1 cable(s) 2.5…25 mm²rigid
Power circuit: screw terminals 2 cable(s) 2.5…16 mm²rigid
Power circuit: screw terminals 1 cable(s) 2.5…25 mm²flexible without cable end
Power circuit: screw terminals 2 cable(s) 2.5…16 mm²flexible without cable end
Power circuit: screw terminals 1 cable(s) 2.5…25 mm²flexible with cable end
Power circuit: screw terminals 2 cable(s) 2.5…10 mm²flexible with cable end
tightening torque
Control circuit: 1.7 N.m - on screw clamp terminal - with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m - on screw clamp terminal - with screwdriver Philips No 2
Power circuit: 5 N.m - on screw terminal - with screwdriver flat Ø 6 to Ø 8 mm
[Ue] rated operational voltage
Power circuit: <= 690 V AC 25...400 Hz
[Ith] conventional free air thermal current
10 A (at 60 °C) for control circuit
80 A (at 60 °C) for power circuit
Irms rated making capacity
250 A DC for control circuit conforming to IEC 60947-5-1
900 A at 440 V for power circuit conforming to IEC 60947
rated breaking capacity
900 A at 440 V for power circuit conforming to IEC 60947
associated fuse rating
10 A gG for control circuit conforming to IEC 60947-5-1
100 A gG at <= 690 V coordination type 1 for power circuit
100 A gG at <= 690 V coordination type 2 for power circuit
power dissipation per pole
3.7 W AC-3
9.6 W AC-1
inrush power in W
19 W (at 20 °C)
hold-in power consumption in W
7.4 W at 20 °C
operating time
20 ms opening
50 ms closing
safety reliability level
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
mechanical durability
10000000 cycles
maximum operating rate
3600 cyc/h 60 °C
minimum switching current
5 mA for control circuit
minimum switching voltage
17 V for control circuit
non-overlap time
1.5 ms on de-energisation between NC and NO contacts
1.5 ms on energisation between NC and NO contacts
insulation resistance
> 10 MOhm for control circuit
rated operational power in W
14 W at 24 V DC-13 - electrical durability: 10000000 cycles - for control circuit
48 W at 24 V DC-13 - electrical durability: 3000000 cycles - for control circuit
96 W at 24 V DC-13 - electrical durability: 1000000 cycles - for control circuit
height
127 mm
width
85 mm
depth
176 mm
net weight
2.185 kg
Environment (see above)
standards
UL 508
CSA C22.2 No 14
IEC 60947-5-1
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
product certifications
LROS (Lloyds register of shipping)
CSA
DNV
RINA
BV
CCC
UL
GOST
GL
IP degree of protection
IP2x conforming to IEC 60529
IP2x conforming to VDE 0106
ambient air temperature for operation
-40…60 °C
60…70 °C with derating
ambient air temperature for storage
-60…80 °C
operating altitude
0...3000 m
fire resistance
850 °C conforming to IEC 60695-2-1
shock resistance
10 gn contactor opened
15 gn contactor closed
vibration resistance
2 gn 5…300 Hz contactor opened
4 gn 5…300 Hz contactor closed
Packing Units (see above)
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Weight
2.169 kg
Package 1 Height
9 cm
Package 1 width
14 cm
Package 1 Length
18.5 cm
Unit Type of Package 2
S02
Number of Units in Package 2
2
Package 2 Weight
4.829 kg
Package 2 Height
15 cm
Package 2 width
30 cm
Package 2 Length
40 cm
Unit Type of Package 3
P06
Number of Units in Package 3
40
Package 3 Weight
99.924 kg
Package 3 Height
77 cm
Package 3 width
80 cm
Package 3 Length
60 cm
Offer Sustainability (see above)
Sustainable offer status
Green Premium product
REACh Regulation
REACh free of SVHC
Yes
EU RoHS Directive
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
China RoHS Regulation
China RoHS declaration
 Pro-active China RoHS declaration (out of China RoHS legal scope)
Environmental Disclosure
Circularity Profile
WEEE
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
PVC free
Yes
California proposition 65
WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Contractual warranty (see above)
Warranty
12 months

Specifications for Schneider CONTACTOR 600VAC 50AMP IEC +OPTIONS

General Information
Arus Pengenal (A) 50A
Uncategorized
Coil DC 24V (BD)

Filter By

Product Public Price Discount Guaranteed Stock QTY Action
Rp 688,266.00 100.00 % Out of Stock
  • # of Pole
  • Arus Pengenal (A)
  • Coil AC
Rp 724,760.00 100.00 % Out of Stock
  • # of Pole
  • Arus Pengenal (A)
  • Coil AC
Rp 688,266.00 100.00 % Out of Stock
  • # of Pole
  • Arus Pengenal (A)
  • Coil AC
Rp 724,760.00 100.00 % Out of Stock
  • # of Pole
  • Arus Pengenal (A)
  • Coil AC
Rp 505,155.00 100.00 % Out of Stock
  • # of Pole
  • Arus Pengenal (A)
  • Coil AC
Rp 513,478.00 100.00 % Out of Stock
  • # of Pole
  • Arus Pengenal (A)
  • Coil AC
HOT PROMO
Main (see above)
range of product
TeSys D
range
TeSys
product or component type
Contactor
device short name
LC1D
contactor application
Motor control
Resistive load
utilisation category
AC-1
AC-2
AC-4
AC-3
control circuit type
DC standard
poles description
3P
pole contact composition
3 NO
[Ie] rated operational current
50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
motor power kW
22 kW at 380...400 V AC 50 Hz (AC-3)
25 kW at 415 V AC 50 Hz (AC-3)
30 kW at 440 V AC 50 Hz (AC-3)
30 kW at 500 V AC 50 Hz (AC-3)
33 kW at 660...690 V AC 50 Hz (AC-3)
15 kW at 220...230 V AC 50 Hz (AC-3)
11 kW at 400 V AC 50 Hz (AC-4)
30 kW at 1000 V AC 50 Hz (AC-3)
Complementary (see above)
coil technology
Built-in bidirectional peak limiting diode suppressor
Front cover
With
motor power hp
3 hp at 115 V AC 60 Hz for 1 phase motors
7.5 hp at 230/240 V AC 60 Hz for 1 phase motors
15 hp at 200/208 V AC 60 Hz for 3 phases motors
15 hp at 230/240 V AC 60 Hz for 3 phases motors
40 hp at 460/480 V AC 60 Hz for 3 phases motors
40 hp at 575/600 V AC 60 Hz for 3 phases motors
auxiliary contacts type
type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
auxiliary contact composition
1 NO + 1 NC
[Uc] control circuit voltage
24 V DC
control circuit voltage limits
0.1...0.3 Uc (-40…70 °C):drop-out DC
0.75...1.25 Uc (-40…60 °C):operational DC
1...1.25 Uc (60…70 °C):operational DC
time constant
34 ms
[Ui] rated insulation voltage
Control circuit: 600 V CSA certified
Control circuit: 600 V UL certified
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Control circuit: 690 V conforming to IEC 60947-1
Power circuit: 690 V conforming to IEC 60947-1
Power circuit: 1000 V conforming to IEC 60947-4-1
[Uimp] rated impulse withstand voltage
8 kV conforming to IEC 60947
overvoltage category
III
mounting support
Rail
Plate
flame retardance
V1 conforming to UL 94
connections - terminals
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²rigid
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²rigid
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Power circuit: screw terminals 1 cable(s) 2.5…25 mm²rigid
Power circuit: screw terminals 2 cable(s) 2.5…16 mm²rigid
Power circuit: screw terminals 1 cable(s) 2.5…25 mm²flexible without cable end
Power circuit: screw terminals 2 cable(s) 2.5…16 mm²flexible without cable end
Power circuit: screw terminals 1 cable(s) 2.5…25 mm²flexible with cable end
Power circuit: screw terminals 2 cable(s) 2.5…10 mm²flexible with cable end
tightening torque
Control circuit: 1.7 N.m - on screw clamp terminal - with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m - on screw clamp terminal - with screwdriver Philips No 2
Power circuit: 5 N.m - on screw terminal - with screwdriver flat Ø 6 to Ø 8 mm
[Ue] rated operational voltage
Power circuit: <= 690 V AC 25...400 Hz
[Ith] conventional free air thermal current
10 A (at 60 °C) for control circuit
80 A (at 60 °C) for power circuit
Irms rated making capacity
250 A DC for control circuit conforming to IEC 60947-5-1
900 A at 440 V for power circuit conforming to IEC 60947
rated breaking capacity
900 A at 440 V for power circuit conforming to IEC 60947
associated fuse rating
10 A gG for control circuit conforming to IEC 60947-5-1
100 A gG at <= 690 V coordination type 1 for power circuit
100 A gG at <= 690 V coordination type 2 for power circuit
power dissipation per pole
3.7 W AC-3
9.6 W AC-1
inrush power in W
19 W (at 20 °C)
hold-in power consumption in W
7.4 W at 20 °C
operating time
20 ms opening
50 ms closing
safety reliability level
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
mechanical durability
10000000 cycles
maximum operating rate
3600 cyc/h 60 °C
minimum switching current
5 mA for control circuit
minimum switching voltage
17 V for control circuit
non-overlap time
1.5 ms on de-energisation between NC and NO contacts
1.5 ms on energisation between NC and NO contacts
insulation resistance
> 10 MOhm for control circuit
rated operational power in W
14 W at 24 V DC-13 - electrical durability: 10000000 cycles - for control circuit
48 W at 24 V DC-13 - electrical durability: 3000000 cycles - for control circuit
96 W at 24 V DC-13 - electrical durability: 1000000 cycles - for control circuit
height
127 mm
width
85 mm
depth
176 mm
net weight
2.185 kg
Environment (see above)
standards
UL 508
CSA C22.2 No 14
IEC 60947-5-1
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
product certifications
LROS (Lloyds register of shipping)
CSA
DNV
RINA
BV
CCC
UL
GOST
GL
IP degree of protection
IP2x conforming to IEC 60529
IP2x conforming to VDE 0106
ambient air temperature for operation
-40…60 °C
60…70 °C with derating
ambient air temperature for storage
-60…80 °C
operating altitude
0...3000 m
fire resistance
850 °C conforming to IEC 60695-2-1
shock resistance
10 gn contactor opened
15 gn contactor closed
vibration resistance
2 gn 5…300 Hz contactor opened
4 gn 5…300 Hz contactor closed
Packing Units (see above)
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Weight
2.169 kg
Package 1 Height
9 cm
Package 1 width
14 cm
Package 1 Length
18.5 cm
Unit Type of Package 2
S02
Number of Units in Package 2
2
Package 2 Weight
4.829 kg
Package 2 Height
15 cm
Package 2 width
30 cm
Package 2 Length
40 cm
Unit Type of Package 3
P06
Number of Units in Package 3
40
Package 3 Weight
99.924 kg
Package 3 Height
77 cm
Package 3 width
80 cm
Package 3 Length
60 cm
Offer Sustainability (see above)
Sustainable offer status
Green Premium product
REACh Regulation
REACh free of SVHC
Yes
EU RoHS Directive
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
China RoHS Regulation
China RoHS declaration
 Pro-active China RoHS declaration (out of China RoHS legal scope)
Environmental Disclosure
Circularity Profile
WEEE
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
PVC free
Yes
California proposition 65
WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Contractual warranty (see above)
Warranty
12 months