Schneider Dark grey station - green flush/red flush pushbuttons D22 and red pilot light
Schneider Dark grey station - green flush/red flush pushbuttons D22 and red pilot light
Terjual 0
0 (0 Rating)
Ulasan (0)
Rp 487,056.00
42.00 %
Rp 839,753.00
Rp 839,753.00
Option not available
Spesifikasi
range of product | Harmony XALD | |
---|---|---|
product or component type | Complete control station | |
device short name | XALD | |
product destination | For XB5 Ø 22 mm control and signalling units | |
control station application | Start-Stop function | |
colour of base of enclosure | Light grey (RAL 7035) | |
colour of cover | Dark grey (RAL 7016) | |
material | Polycarbonate | |
operator profile | 2 flush push-buttons - 1 central pilot light | |
operators description | Green ''I'' 1 NO - red ''O'' 1 NC | |
control station composition | 1 flush push-button, green 1 NO I marking 1 flush push-button, red 1 NC O marking 1 pilot light | |
marking location | Marking on push-button | |
contact operation | Slow-break | |
light source | Integrated and protected LED | |
light source colour | Red | |
[Us] rated supply voltage | 230 V AC |
cable entry | 2 knock-outs for cable entry, clamping capacity: 14 mm 2 knock-outs for Pg 13 cable gland and ISO M20, clamping capacity: 12 mm | |
---|---|---|
net weight | 0.261 kg | |
resistance to high pressure washer | 7000000 Pa at 55 °C, distance : 0.1 m | |
colour of marking | White marking when green, red or black caps Black marking when white caps | |
positive opening | With conforming to EN/IEC 60947-5-1 appendix K | |
operating travel | 1.5 mm (NC changing electrical state) 2.6 mm (NO changing electrical state) 4.3 mm (total travel) | |
operating force | 3.5 N NC changing electrical state 3.8 N NO changing electrical state | |
mechanical durability | 10000000 cycles | |
connections - terminals | Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to EN/IEC 60947-1 Screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to EN/IEC 60947-1 | |
tightening torque | 0.8…1.2 N.m conforming to EN/IEC 60947-1 | |
shape of screw head | Cross compatible with Philips no 1 screwdriver Cross compatible with pozidriv No 1 screwdriver Slotted compatible with flat Ø 4 mm screwdriver Slotted compatible with flat Ø 5.5 mm screwdriver | |
contacts material | Silver alloy (Ag/Ni) | |
short-circuit protection | 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1 | |
[Ith] conventional free air thermal current | 10 A conforming to EN/IEC 60947-5-1 | |
[Ui] rated insulation voltage | 600 V (pollution degree 3) conforming to EN/IEC 60947-1 | |
[Uimp] rated impulse withstand voltage | 6 kV EN/IEC 60947-1 | |
[Ie] rated operational current | 6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1 1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1 0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 | |
electrical durability | 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C | |
electrical reliability | Λ < 10exp(-6) at 5 V, 1 mA conforming to EN/IEC 60947-5-4 Λ < 10exp(-8) at 17 V, 5 mA conforming to EN/IEC 60947-5-4 | |
signalling type | Steady | |
supply voltage limits | 195…264 V AC | |
current consumption | 14 mA | |
service life | 100000 h at rated voltage and 25 °C | |
surge withstand | 1 kV conforming to IEC 61000-4-5 |
protective treatment | TH | |
---|---|---|
ambient air temperature for storage | -40…70 °C | |
ambient air temperature for operation | -40…70 °C | |
overvoltage category | Class II conforming to IEC 60536 | |
IP degree of protection | IP66 conforming to IEC 60529 IP67 IP69 IP69K | |
NEMA degree of protection | NEMA 13 NEMA 4X | |
IK degree of protection | IK05 conforming to EN 50102 | |
standards | EN/IEC 60947-1 EN/IEC 60947-5-4 JIS C8201-5-1 CSA C22.2 No 14 EN/IEC 60947-5-5 EN/IEC 60947-5-1 UL 508 JIS C8201-1 | |
vibration resistance | 5 gn (f= 12…500 Hz) conforming to IEC 60068-2-6 | |
shock resistance | 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27 | |
resistance to fast transients | 2 kV conforming to IEC 61000-4-4 | |
resistance to electromagnetic fields | 10 V/m conforming to IEC 61000-4-3 | |
resistance to electrostatic discharge | 6 kV on contact (on metal parts) conforming to IEC 61000-4-2 8 kV in free air (in insulating parts) conforming to IEC 61000-4-2 | |
electromagnetic emission | Class B conforming to IEC 55011 |
Unit Type of Package 1 | PCE | |
---|---|---|
Number of Units in Package 1 | 1 | |
Package 1 Weight | 289 g | |
Package 1 Height | 7.1 cm | |
Package 1 width | 9.8 cm | |
Package 1 Length | 14.1 cm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
EU RoHS Directive | Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | ||
Environmental Disclosure | ||
Circularity Profile | ||
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Warranty | 12 months |
---|
Filter By
range of product | Harmony XALD | |
---|---|---|
product or component type | Complete control station | |
device short name | XALD | |
product destination | For XB5 Ø 22 mm control and signalling units | |
control station application | Start-Stop function | |
colour of base of enclosure | Light grey (RAL 7035) | |
colour of cover | Dark grey (RAL 7016) | |
material | Polycarbonate | |
operator profile | 2 flush push-buttons - 1 central pilot light | |
operators description | Green ''I'' 1 NO - red ''O'' 1 NC | |
control station composition | 1 flush push-button, green 1 NO I marking 1 flush push-button, red 1 NC O marking 1 pilot light | |
marking location | Marking on push-button | |
contact operation | Slow-break | |
light source | Integrated and protected LED | |
light source colour | Red | |
[Us] rated supply voltage | 230 V AC |
cable entry | 2 knock-outs for cable entry, clamping capacity: 14 mm 2 knock-outs for Pg 13 cable gland and ISO M20, clamping capacity: 12 mm | |
---|---|---|
net weight | 0.261 kg | |
resistance to high pressure washer | 7000000 Pa at 55 °C, distance : 0.1 m | |
colour of marking | White marking when green, red or black caps Black marking when white caps | |
positive opening | With conforming to EN/IEC 60947-5-1 appendix K | |
operating travel | 1.5 mm (NC changing electrical state) 2.6 mm (NO changing electrical state) 4.3 mm (total travel) | |
operating force | 3.5 N NC changing electrical state 3.8 N NO changing electrical state | |
mechanical durability | 10000000 cycles | |
connections - terminals | Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to EN/IEC 60947-1 Screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to EN/IEC 60947-1 | |
tightening torque | 0.8…1.2 N.m conforming to EN/IEC 60947-1 | |
shape of screw head | Cross compatible with Philips no 1 screwdriver Cross compatible with pozidriv No 1 screwdriver Slotted compatible with flat Ø 4 mm screwdriver Slotted compatible with flat Ø 5.5 mm screwdriver | |
contacts material | Silver alloy (Ag/Ni) | |
short-circuit protection | 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1 | |
[Ith] conventional free air thermal current | 10 A conforming to EN/IEC 60947-5-1 | |
[Ui] rated insulation voltage | 600 V (pollution degree 3) conforming to EN/IEC 60947-1 | |
[Uimp] rated impulse withstand voltage | 6 kV EN/IEC 60947-1 | |
[Ie] rated operational current | 6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1 1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1 0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 | |
electrical durability | 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C | |
electrical reliability | Λ < 10exp(-6) at 5 V, 1 mA conforming to EN/IEC 60947-5-4 Λ < 10exp(-8) at 17 V, 5 mA conforming to EN/IEC 60947-5-4 | |
signalling type | Steady | |
supply voltage limits | 195…264 V AC | |
current consumption | 14 mA | |
service life | 100000 h at rated voltage and 25 °C | |
surge withstand | 1 kV conforming to IEC 61000-4-5 |
protective treatment | TH | |
---|---|---|
ambient air temperature for storage | -40…70 °C | |
ambient air temperature for operation | -40…70 °C | |
overvoltage category | Class II conforming to IEC 60536 | |
IP degree of protection | IP66 conforming to IEC 60529 IP67 IP69 IP69K | |
NEMA degree of protection | NEMA 13 NEMA 4X | |
IK degree of protection | IK05 conforming to EN 50102 | |
standards | EN/IEC 60947-1 EN/IEC 60947-5-4 JIS C8201-5-1 CSA C22.2 No 14 EN/IEC 60947-5-5 EN/IEC 60947-5-1 UL 508 JIS C8201-1 | |
vibration resistance | 5 gn (f= 12…500 Hz) conforming to IEC 60068-2-6 | |
shock resistance | 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27 | |
resistance to fast transients | 2 kV conforming to IEC 61000-4-4 | |
resistance to electromagnetic fields | 10 V/m conforming to IEC 61000-4-3 | |
resistance to electrostatic discharge | 6 kV on contact (on metal parts) conforming to IEC 61000-4-2 8 kV in free air (in insulating parts) conforming to IEC 61000-4-2 | |
electromagnetic emission | Class B conforming to IEC 55011 |
Unit Type of Package 1 | PCE | |
---|---|---|
Number of Units in Package 1 | 1 | |
Package 1 Weight | 289 g | |
Package 1 Height | 7.1 cm | |
Package 1 width | 9.8 cm | |
Package 1 Length | 14.1 cm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
EU RoHS Directive | Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | ||
Environmental Disclosure | ||
Circularity Profile | ||
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Warranty | 12 months |
---|
Recently Viewed Products
Schneider Dark grey station - green flush/red flush pushbuttons D22 and red pilot light
Rp 839,753.00
Rp 540,632.00