Schneider EasyPact TVS contactor 3P(3 NO) - AC-3 - <= 440 V 32A - 48 V AC coil
# of Pole : 3
Arus Pengenal (A) : 48A
Coil AC : 48V (E7)
Schneider EasyPact TVS contactor 3P(3 NO) - AC-3 - <= 440 V 32A - 48 V AC coil
Terjual 0
0 (0 Rating)
Ulasan (0)
Rp 478,905.00
44.00 %
Rp 855,188.00
Rp 855,188.00
Option not available
Spesifikasi
range | EasyPact | |
---|---|---|
product name | EasyPact TVS | |
product or component type | Contactor | |
device short name | LC1E | |
contactor application | Motor control Resistive load | |
utilisation category | AC-3 AC-1 | |
poles description | 3P | |
power pole contact composition | 3 NO | |
[Ue] rated operational voltage | Power circuit: <= 690 V AC 50/60 Hz | |
[Ie] rated operational current | 32 A (at <55 °C) at <= 440 V AC AC-3 for power circuit 50 A (at <60 °C) at <= 440 V AC AC-1 for power circuit | |
motor power kW | 7.5 kW at 220...230 V AC 50/60 Hz 15 kW at 380...400 V 15 kW at 415 V 15 kW at 440 V 18.5 kW at 500 V 18.5 kW at 660...690 V | |
control circuit type | AC at 50/60 Hz | |
[Uc] control circuit voltage | 48 V AC 50/60 Hz | |
height | 84 mm | |
width | 56 mm | |
depth | 86 mm | |
net weight | 0.45 kg | |
colour | Grey (RAL 7011) |
auxiliary contact composition | 1 NO | |
---|---|---|
[Uimp] rated impulse withstand voltage | 6 kV coil not connected to the power circuit conforming to IEC 60947 | |
[Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 | |
overvoltage category | III | |
Irms rated making capacity | 320 A at 440 V AC for power circuit conforming to IEC 60947-4-1 | |
rated breaking capacity | 256 A at 440 V for power circuit conforming to IEC 60947 | |
[Icw] rated short-time withstand current | 260 A 40 °C - 10 s for power circuit 138 A 40 °C - 60 s for power circuit 60 A 40 °C - 600 s for power circuit | |
associated fuse rating | 10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1 63 A gG at <= 690 V coordination type 1 for power circuit | |
average impedance | 2.5 mOhm - Ith 50 A 50 Hz for power circuit | |
power dissipation per pole | 2 W AC-3 5 W AC-1 | |
control circuit voltage limits | Operational: 0.85...1.1 Uc at 50/60 Hz (at <55 °C) Drop-out: 0.3...0.6 Uc at 50/60 Hz (at <55 °C) | |
operating time | 12...22 ms on closing 4...19 ms on opening | |
mechanical durability | 8000000 cycles | |
maximum operating rate | 1800 cyc/h 60 °C | |
inrush power in VA | 95 VA 50 Hz cos phi 0.75 (at 20 °C) 95 VA 60 Hz cos phi 0.75 (at 20 °C) | |
hold-in power consumption in VA | 8.3 VA 50 Hz cos phi 0.3 (at 20 °C) 8.5 VA 60 Hz cos phi 0.3 (at 20 °C) | |
heat dissipation | 2…3 W for control circuit | |
minimum switching current | 5 mA for control circuit | |
minimum switching voltage | 17 V for control circuit | |
non-overlap time | 1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact | |
insulation resistance | > 10 MOhm for control circuit | |
electrical durability | 1000000 cycles AC-3 350000 cycles AC-1 | |
mounting support | Plate DIN rail | |
connections - terminals | Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 1 1.5…6 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 2 1.5…6 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 1 1…6 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible with cable end | |
Recommended tightening torque | Control circuit: 1.2 N.m Power circuit: 2.1 N.m | |
Max tightening torque | Control circuit: 1.4 N.m Power circuit: 2.3 N.m |
standards | IEC 60947-5-1 IEC 60947-4-1 IEC 60947-1 | |
---|---|---|
product certifications | EAC CE | |
IP degree of protection | IP2x conforming to IEC 60529 | |
protective treatment | TH (pollution degree 3) conforming to IEC 60068-2-30 test Db | |
pollution degree | 3 | |
ambient air temperature for operation | -5…55 °C | |
ambient air temperature for storage | -60…80 °C | |
permissible ambient air temperature around the device | -20…70 °C at Uc | |
operating altitude | 3000 m without derating | |
fire resistance | 850 °C conforming to IEC 60695-2-1 | |
mechanical robustness | Vibrations contactor open: 1.5 Gn, 5...300 Hz Vibrations contactor closed: 3 Gn, 5...300 Hz Shocks contactor closed: 10 Gn for 11 ms Shocks contactor open: 6 Gn for 11 ms |
Package 1 Weight | 431.000 g | |
---|---|---|
Package 1 Height | 86.000 mm | |
Package 1 width | 56.000 mm | |
Package 1 Length | 84.000 mm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
REACh free of SVHC | Yes | |
EU RoHS Directive | Compliant EU RoHS Declaration | |
Toxic heavy metal free | Yes | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | ||
Environmental Disclosure | ||
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Specifications for Schneider EasyPact TVS contactor 3P(3 NO) - AC-3 - <= 440 V 32A - 48 V AC coil
General Information | |
---|---|
# of Pole | 3 |
Arus Pengenal (A) | 48A |
Uncategorized | |
Coil AC | 48V (E7) |
range | EasyPact | |
---|---|---|
product name | EasyPact TVS | |
product or component type | Contactor | |
device short name | LC1E | |
contactor application | Motor control Resistive load | |
utilisation category | AC-3 AC-1 | |
poles description | 3P | |
power pole contact composition | 3 NO | |
[Ue] rated operational voltage | Power circuit: <= 690 V AC 50/60 Hz | |
[Ie] rated operational current | 32 A (at <55 °C) at <= 440 V AC AC-3 for power circuit 50 A (at <60 °C) at <= 440 V AC AC-1 for power circuit | |
motor power kW | 7.5 kW at 220...230 V AC 50/60 Hz 15 kW at 380...400 V 15 kW at 415 V 15 kW at 440 V 18.5 kW at 500 V 18.5 kW at 660...690 V | |
control circuit type | AC at 50/60 Hz | |
[Uc] control circuit voltage | 48 V AC 50/60 Hz | |
height | 84 mm | |
width | 56 mm | |
depth | 86 mm | |
net weight | 0.45 kg | |
colour | Grey (RAL 7011) |
auxiliary contact composition | 1 NO | |
---|---|---|
[Uimp] rated impulse withstand voltage | 6 kV coil not connected to the power circuit conforming to IEC 60947 | |
[Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 | |
overvoltage category | III | |
Irms rated making capacity | 320 A at 440 V AC for power circuit conforming to IEC 60947-4-1 | |
rated breaking capacity | 256 A at 440 V for power circuit conforming to IEC 60947 | |
[Icw] rated short-time withstand current | 260 A 40 °C - 10 s for power circuit 138 A 40 °C - 60 s for power circuit 60 A 40 °C - 600 s for power circuit | |
associated fuse rating | 10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1 63 A gG at <= 690 V coordination type 1 for power circuit | |
average impedance | 2.5 mOhm - Ith 50 A 50 Hz for power circuit | |
power dissipation per pole | 2 W AC-3 5 W AC-1 | |
control circuit voltage limits | Operational: 0.85...1.1 Uc at 50/60 Hz (at <55 °C) Drop-out: 0.3...0.6 Uc at 50/60 Hz (at <55 °C) | |
operating time | 12...22 ms on closing 4...19 ms on opening | |
mechanical durability | 8000000 cycles | |
maximum operating rate | 1800 cyc/h 60 °C | |
inrush power in VA | 95 VA 50 Hz cos phi 0.75 (at 20 °C) 95 VA 60 Hz cos phi 0.75 (at 20 °C) | |
hold-in power consumption in VA | 8.3 VA 50 Hz cos phi 0.3 (at 20 °C) 8.5 VA 60 Hz cos phi 0.3 (at 20 °C) | |
heat dissipation | 2…3 W for control circuit | |
minimum switching current | 5 mA for control circuit | |
minimum switching voltage | 17 V for control circuit | |
non-overlap time | 1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact | |
insulation resistance | > 10 MOhm for control circuit | |
electrical durability | 1000000 cycles AC-3 350000 cycles AC-1 | |
mounting support | Plate DIN rail | |
connections - terminals | Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 1 1.5…6 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 2 1.5…6 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 1 1…6 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible with cable end | |
Recommended tightening torque | Control circuit: 1.2 N.m Power circuit: 2.1 N.m | |
Max tightening torque | Control circuit: 1.4 N.m Power circuit: 2.3 N.m |
standards | IEC 60947-5-1 IEC 60947-4-1 IEC 60947-1 | |
---|---|---|
product certifications | EAC CE | |
IP degree of protection | IP2x conforming to IEC 60529 | |
protective treatment | TH (pollution degree 3) conforming to IEC 60068-2-30 test Db | |
pollution degree | 3 | |
ambient air temperature for operation | -5…55 °C | |
ambient air temperature for storage | -60…80 °C | |
permissible ambient air temperature around the device | -20…70 °C at Uc | |
operating altitude | 3000 m without derating | |
fire resistance | 850 °C conforming to IEC 60695-2-1 | |
mechanical robustness | Vibrations contactor open: 1.5 Gn, 5...300 Hz Vibrations contactor closed: 3 Gn, 5...300 Hz Shocks contactor closed: 10 Gn for 11 ms Shocks contactor open: 6 Gn for 11 ms |
Package 1 Weight | 431.000 g | |
---|---|---|
Package 1 Height | 86.000 mm | |
Package 1 width | 56.000 mm | |
Package 1 Length | 84.000 mm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
REACh free of SVHC | Yes | |
EU RoHS Directive | Compliant EU RoHS Declaration | |
Toxic heavy metal free | Yes | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | ||
Environmental Disclosure | ||
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Recently Viewed Products
Schneider EasyPact TVS contactor 3P(3 NO) - AC-3 - <= 440 V 32A - 48 V AC coil
Rp 855,188.00
Rp 531,584.00