Spesifikasi
| range of product | Harmony K | |
|---|---|---|
| product or component type | Complete cam switch | |
| component name | K1 | |
| [Ith] conventional free air thermal current | 12 A | |
| fixing mode | Ø 16 or 22 mm hole | |
| cam switch head type | With front plate 45 x 45 mm | |
| type of operator | Black handle, length = 35 mm | |
| rotary handle padlocking | Without | |
| presentation of legend | With metallic legend black marking | |
| cam switch function | Switch | |
| return | Without | |
| off position | With Off position | |
| poles description | 4P | |
| switching positions | Right: 0° - 45° - 90° - 135° - 180° | |
| IP degree of protection | IP65 conforming to IEC 529 IP65 conforming to NF C 20-010 |
| number of steps | 45 | |
|---|---|---|
| [Ui] rated insulation voltage | 690 V (pollution degree 3) conforming to IEC 60947-1 | |
| [Ithe] conventional enclosed thermal current | 10 A | |
| rated operational power in W | 10500 W AC-21, 500...660 V 3 phases conforming to IEC 947-3 1100 W AC-3, 230 V 3 phases conforming to IEC 947-3 1500 W AC-23A, 230 V 3 phases conforming to IEC 947-3 1500 W AC-3, 400 V 1 phase conforming to IEC 947-3 1500 W AC-3, 400 V 3 phases conforming to IEC 947-3 1500 W AC-3, 500 V 3 phases conforming to IEC 947-3 1500 W AC-3, 690 V 3 phases conforming to IEC 947-3 2200 W AC-23A, 400 V 3 phases conforming to IEC 947-3 2200 W AC-23A, 500 V 3 phases conforming to IEC 947-3 2200 W AC-23A, 690 V 3 phases conforming to IEC 947-3 4800 W AC-21, 230 V 3 phases conforming to IEC 947-3 600 W AC-3, 230 V 1 phase conforming to IEC 947-3 8300 W AC-21, 400 V 3 phases conforming to IEC 947-3 | |
| [Ie] rated operational current AC | 1.8 A at 690 V AC-3 3 phases conforming to IEC 947-3 2.8 A at 500 V AC-3 3 phases conforming to IEC 947-3 2.8 A at 690 V AC-23A 3 phases conforming to IEC 947-3 3.3 A at 400 V AC-3 3 phases conforming to IEC 947-3 3.8 A at 500 V AC-23A 3 phases conforming to IEC 947-3 4.6 A at 230 V AC-3 3 phases conforming to IEC 947-3 4.8 A at 400 V AC-23A 3 phases conforming to IEC 947-3 5.6 A at 230 V AC-23A 3 phases conforming to IEC 947-3 1 A at 500 V AC-15 conforming to IEC 947-5-1 2 A at 400 V AC-15 conforming to IEC 947-5-1 3 A at 230 V AC-15 conforming to IEC 947-5-1 | |
| electrical durability | 1000000 cycles AC-15 1000000 cycles AC-21 500000 cycles AC-23 500000 cycles AC-3 | |
| maximum operating rate | 8333 cyc/mn AC-15 2.5 cyc/mn AC-21 2.5 cyc/mn AC-23 2.5 cyc/mn AC-3 | |
| short-circuit current | 10000 A | |
| short-circuit protection | 16 A cartridge fuse, type gG | |
| [Uimp] rated impulse withstand voltage | 4 kV in isolating function 6 kV conforming to IEC 947-1 | |
| contact operation | Slow-break | |
| positive opening | With | |
| electrical connection | Captive screw clamp terminals flexible, clamping capacity: 2 x 1.5 mm² Captive screw clamp terminals solid, clamping capacity: 1 x 2.5 mm² | |
| mechanical durability | 1000000 cycles | |
| CAD overall width | 45 mm | |
| CAD overall height | 50 mm | |
| CAD overall depth | 49 mm | |
| net weight | 0.123 kg |
| standards | EN/IEC 60947-3 for power circuit EN/IEC 60947-5-1 for control circuit CSA C22.2 No 14 for power circuit CSA C22.2 No 14 for control circuit UL 508 for power circuit UL 508 for control circuit | |
|---|---|---|
| product certifications | CSA 240 V 3 hp 3 phases 2 -pole(s) UL 240 V 0.33 hp 1 phase 2 -pole(s) CSA 240 V 1 hp 1 phase UL 240 V 1 hp 3 phases | |
| protective treatment | TC | |
| ambient air temperature for operation | -25…55 °C | |
| ambient air temperature for storage | -40…70 °C | |
| shock resistance | 30 gn conforming to IEC 68-2-27 | |
| vibration resistance | 5 gn conforming to IEC 68-2-6 (f = 10…150 Hz) | |
| overvoltage category | Class II conforming to IEC 536 Class II conforming to NF C 20-030 |
| Package 1 Weight | 1.000 g |
|---|
| REACh Regulation | ||
|---|---|---|
| REACh free of SVHC | Yes | |
| EU RoHS Directive | Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration | |
| Toxic heavy metal free | Yes | |
| Mercury free | Yes | |
| RoHS exemption information | ||
| China RoHS Regulation | ||
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| range of product | Harmony K | |
|---|---|---|
| product or component type | Complete cam switch | |
| component name | K1 | |
| [Ith] conventional free air thermal current | 12 A | |
| fixing mode | Ø 16 or 22 mm hole | |
| cam switch head type | With front plate 45 x 45 mm | |
| type of operator | Black handle, length = 35 mm | |
| rotary handle padlocking | Without | |
| presentation of legend | With metallic legend black marking | |
| cam switch function | Switch | |
| return | Without | |
| off position | With Off position | |
| poles description | 4P | |
| switching positions | Right: 0° - 45° - 90° - 135° - 180° | |
| IP degree of protection | IP65 conforming to IEC 529 IP65 conforming to NF C 20-010 |
| number of steps | 45 | |
|---|---|---|
| [Ui] rated insulation voltage | 690 V (pollution degree 3) conforming to IEC 60947-1 | |
| [Ithe] conventional enclosed thermal current | 10 A | |
| rated operational power in W | 10500 W AC-21, 500...660 V 3 phases conforming to IEC 947-3 1100 W AC-3, 230 V 3 phases conforming to IEC 947-3 1500 W AC-23A, 230 V 3 phases conforming to IEC 947-3 1500 W AC-3, 400 V 1 phase conforming to IEC 947-3 1500 W AC-3, 400 V 3 phases conforming to IEC 947-3 1500 W AC-3, 500 V 3 phases conforming to IEC 947-3 1500 W AC-3, 690 V 3 phases conforming to IEC 947-3 2200 W AC-23A, 400 V 3 phases conforming to IEC 947-3 2200 W AC-23A, 500 V 3 phases conforming to IEC 947-3 2200 W AC-23A, 690 V 3 phases conforming to IEC 947-3 4800 W AC-21, 230 V 3 phases conforming to IEC 947-3 600 W AC-3, 230 V 1 phase conforming to IEC 947-3 8300 W AC-21, 400 V 3 phases conforming to IEC 947-3 | |
| [Ie] rated operational current AC | 1.8 A at 690 V AC-3 3 phases conforming to IEC 947-3 2.8 A at 500 V AC-3 3 phases conforming to IEC 947-3 2.8 A at 690 V AC-23A 3 phases conforming to IEC 947-3 3.3 A at 400 V AC-3 3 phases conforming to IEC 947-3 3.8 A at 500 V AC-23A 3 phases conforming to IEC 947-3 4.6 A at 230 V AC-3 3 phases conforming to IEC 947-3 4.8 A at 400 V AC-23A 3 phases conforming to IEC 947-3 5.6 A at 230 V AC-23A 3 phases conforming to IEC 947-3 1 A at 500 V AC-15 conforming to IEC 947-5-1 2 A at 400 V AC-15 conforming to IEC 947-5-1 3 A at 230 V AC-15 conforming to IEC 947-5-1 | |
| electrical durability | 1000000 cycles AC-15 1000000 cycles AC-21 500000 cycles AC-23 500000 cycles AC-3 | |
| maximum operating rate | 8333 cyc/mn AC-15 2.5 cyc/mn AC-21 2.5 cyc/mn AC-23 2.5 cyc/mn AC-3 | |
| short-circuit current | 10000 A | |
| short-circuit protection | 16 A cartridge fuse, type gG | |
| [Uimp] rated impulse withstand voltage | 4 kV in isolating function 6 kV conforming to IEC 947-1 | |
| contact operation | Slow-break | |
| positive opening | With | |
| electrical connection | Captive screw clamp terminals flexible, clamping capacity: 2 x 1.5 mm² Captive screw clamp terminals solid, clamping capacity: 1 x 2.5 mm² | |
| mechanical durability | 1000000 cycles | |
| CAD overall width | 45 mm | |
| CAD overall height | 50 mm | |
| CAD overall depth | 49 mm | |
| net weight | 0.123 kg |
| standards | EN/IEC 60947-3 for power circuit EN/IEC 60947-5-1 for control circuit CSA C22.2 No 14 for power circuit CSA C22.2 No 14 for control circuit UL 508 for power circuit UL 508 for control circuit | |
|---|---|---|
| product certifications | CSA 240 V 3 hp 3 phases 2 -pole(s) UL 240 V 0.33 hp 1 phase 2 -pole(s) CSA 240 V 1 hp 1 phase UL 240 V 1 hp 3 phases | |
| protective treatment | TC | |
| ambient air temperature for operation | -25…55 °C | |
| ambient air temperature for storage | -40…70 °C | |
| shock resistance | 30 gn conforming to IEC 68-2-27 | |
| vibration resistance | 5 gn conforming to IEC 68-2-6 (f = 10…150 Hz) | |
| overvoltage category | Class II conforming to IEC 536 Class II conforming to NF C 20-030 |
| Package 1 Weight | 1.000 g |
|---|
| REACh Regulation | ||
|---|---|---|
| REACh free of SVHC | Yes | |
| EU RoHS Directive | Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration | |
| Toxic heavy metal free | Yes | |
| Mercury free | Yes | |
| RoHS exemption information | ||
| China RoHS Regulation | ||
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |