• Sign up now and get discount up to 47%

Schneider Kontaktor 3P 6A 1 NO aux 24V DC Coil - LP1K0610BD

# of Pole : 3

P (kW) : 2.2

Rp 520,201.00 Rp 291,312.00 291312 IDR

Rp 520,201.00

Option not available

  • # of Pole
  • P (kW)

This combination does not exist.

Add to Cart

Schneider Kontaktor 3P 6A 1 NO aux 24V DC Coil - LP1K0610BD
Terjual 0
0 (0 Rating)
Ulasan (0)

Rp 291,312.00
44.00 % Rp 520,201.00 291312 IDR

Rp 520,201.00

Option not available

Atur Jumlah & Catatan
Stock Total: Out of Stock

# of Pole : 3

P (kW) : 2.2

Spesifikasi

[Deskripsi] 1. product name : TeSys K 2. device short name : LP1K 3. device application : Control 4. contactor application : Motor control 5. utilisation category : -AC-4 -AC-3 6. poles description : 3P 7. power pole contact composition : 3 NO 8. [Ue] rated operational voltage : -Power circuit: 690 V AC 50/60 Hz -Signalling circuit: <= 690 V AC 50/60 Hz 9. [Ie] rated operational current : 6 A at <= 440 V AC AC-3 for power circuit 10. control circuit type : DC standard 11. [Uc] control circuit voltage : 24 V DC 12. motor power kW : -1.5 kW at 220...230 V AC 50/60 Hz AC-3 -2.2 kW at 380...415 V AC 50/60 Hz AC-3 -3 kW at 440 V AC 50/60 Hz AC-3 -3 kW at 480 V AC 50/60 Hz AC-3 -3 kW at 500...600 V AC 50/60 Hz AC-3 -3 kW at 660...690 V AC 50/60 Hz AC-3 -1.5 kW at 400 V AC 50/60 Hz AC-4 13. auxiliary contact composition : 1 NO 14. [Uimp] rated impulse withstand voltage : 8 kV 15. overvoltage category : III 16. [Ith] conventional free air thermal current : -20 A (at 50 °C) for power circuit -10 A (at 50 °C) for signalling circuit 17. Irms rated making capacity : -110 A AC for power circuit conforming to NF C 63-110 -110 A AC for power circuit conforming to IEC 60947 -110 A AC for signalling circuit conforming to IEC 60947 18. rated breaking capacity : -110 A at 415 V conforming to IEC 60947 -110 A at 440 V conforming to IEC 60947 -80 A at 500 V conforming to IEC 60947 -110 A at 220...230 V conforming to IEC 60947 -110 A at 380...400 V conforming to IEC 60947 -70 A at 660...690 V conforming to IEC 60947 19. auxiliary contacts type : type instantaneous 1 NO 20. minimum switching current : 5 mA for signalling circuit 21. minimum switching voltage : 17 V for signalling circuit 22. mounting support : -Rail -Plate 23. tightening torque : -1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2 -1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm 24. operating time : -30...40 ms coil energisation and NO closing -10 ms coil de-energisation and NO opening 25. safety reliability level : -B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 -B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 26. non overlap distance : 0.5 mm 27. mechanical durability : 10 Mcycles 28. electrical durability : 1.3 Mcycles 6 A AC-3 at Ue <= 440 V 29. depth : 57 mm 30. net weight : 0.225 kg

Specifications for Schneider Kontaktor 3P 6A 1 NO aux 24V DC Coil - LP1K0610BD

# of Pole 3
P (kW) 2.2

Filter By

Product Public Price Discount Guaranteed Stock QTY Action
Rp 754,852.00 100.00 % 15
  • # of Pole
  • P (kW)
  • Icu (kA)
Rp 754,852.00 100.00 % 3
  • # of Pole
  • P (kW)
  • Icu (kA)
HOT PROMO

[Deskripsi] 1. product name : TeSys K 2. device short name : LP1K 3. device application : Control 4. contactor application : Motor control 5. utilisation category : -AC-4 -AC-3 6. poles description : 3P 7. power pole contact composition : 3 NO 8. [Ue] rated operational voltage : -Power circuit: 690 V AC 50/60 Hz -Signalling circuit: <= 690 V AC 50/60 Hz 9. [Ie] rated operational current : 6 A at <= 440 V AC AC-3 for power circuit 10. control circuit type : DC standard 11. [Uc] control circuit voltage : 24 V DC 12. motor power kW : -1.5 kW at 220...230 V AC 50/60 Hz AC-3 -2.2 kW at 380...415 V AC 50/60 Hz AC-3 -3 kW at 440 V AC 50/60 Hz AC-3 -3 kW at 480 V AC 50/60 Hz AC-3 -3 kW at 500...600 V AC 50/60 Hz AC-3 -3 kW at 660...690 V AC 50/60 Hz AC-3 -1.5 kW at 400 V AC 50/60 Hz AC-4 13. auxiliary contact composition : 1 NO 14. [Uimp] rated impulse withstand voltage : 8 kV 15. overvoltage category : III 16. [Ith] conventional free air thermal current : -20 A (at 50 °C) for power circuit -10 A (at 50 °C) for signalling circuit 17. Irms rated making capacity : -110 A AC for power circuit conforming to NF C 63-110 -110 A AC for power circuit conforming to IEC 60947 -110 A AC for signalling circuit conforming to IEC 60947 18. rated breaking capacity : -110 A at 415 V conforming to IEC 60947 -110 A at 440 V conforming to IEC 60947 -80 A at 500 V conforming to IEC 60947 -110 A at 220...230 V conforming to IEC 60947 -110 A at 380...400 V conforming to IEC 60947 -70 A at 660...690 V conforming to IEC 60947 19. auxiliary contacts type : type instantaneous 1 NO 20. minimum switching current : 5 mA for signalling circuit 21. minimum switching voltage : 17 V for signalling circuit 22. mounting support : -Rail -Plate 23. tightening torque : -1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2 -1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm 24. operating time : -30...40 ms coil energisation and NO closing -10 ms coil de-energisation and NO opening 25. safety reliability level : -B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 -B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 26. non overlap distance : 0.5 mm 27. mechanical durability : 10 Mcycles 28. electrical durability : 1.3 Mcycles 6 A AC-3 at Ue <= 440 V 29. depth : 57 mm 30. net weight : 0.225 kg