Spesifikasi
range of product | Harmony Electromechanical Relays | |
---|---|---|
series name | Miniature | |
product or component type | Plug-in relay | |
device short name | RXM | |
contacts type and composition | 2 C/O | |
[Uc] control circuit voltage | 120 V AC 50/60 Hz | |
[Ithe] conventional enclosed thermal current | 12 A at -40…55 °C | |
status LED | With | |
control type | Lockable test button | |
utilisation coefficient | 20 % |
shape of pin | Flat | |
---|---|---|
[Ui] rated insulation voltage | 250 V conforming to IEC 300 V conforming to CSA 300 V conforming to UL | |
[Uimp] rated impulse withstand voltage | 4 kV during 1.2/50 µs | |
contacts material | AgNi | |
[Ie] rated operational current | 12 A at 28 V (DC) NO conforming to IEC 12 A at 250 V (AC) NO conforming to IEC 6 A at 28 V (DC) NC conforming to IEC 6 A at 250 V (AC) NC conforming to IEC 12 A at 28 V (DC) conforming to UL 12 A at 277 V (AC) conforming to UL | |
maximum switching voltage | 250 V conforming to IEC | |
resistive rated load | 12 A at 250 V AC 12 A at 28 V DC | |
maximum switching capacity | 3000 VA/336 W | |
minimum switching capacity | 170 mW at 10 mA, 17 V | |
operating rate | <= 1200 cycles/hour under load <= 18000 cycles/hour no-load | |
mechanical durability | 10000000 cycles | |
electrical durability | 100000 cycles for resistive load | |
average coil consumption in VA | 1.2 at 60 Hz | |
average consumption | 1.2 VA at 60 Hz | |
drop-out voltage threshold | >= 0.15 Uc | |
operate time | 20 ms | |
release time | 20 ms | |
average coil resistance | 3630 Ohm at 20 °C +/- 15 % | |
rated operational voltage limits | 96...132 V AC | |
safety reliability data | B10d = 100000 | |
protection category | RT I | |
test levels | Level A group mounting | |
operating position | Any position | |
CAD overall height | 79 mm | |
CAD overall depth | 78.45 mm | |
net weight | 0.037 kg | |
device presentation | Complete product |
dielectric strength | 1300 V AC between contacts with micro disconnection 2000 V AC between coil and contact 2000 V AC between poles | |
---|---|---|
product certifications | GOST CSA UL Lloyd's CE | |
standards | CSA C22.2 No 14 EN/IEC 61810-1 UL 508 | |
ambient air temperature for storage | -40…85 °C | |
ambient air temperature for operation | -40…55 °C | |
vibration resistance | 3 gn, amplitude = +/- 1 mm (f = 10…150 Hz)5 cycles in operation 5 gn, amplitude = +/- 1 mm (f = 10…150 Hz)5 cycles not operating | |
IP degree of protection | IP40 conforming to EN/IEC 60529 | |
shock resistance | 10 gn for in operation 30 gn for not operating | |
pollution degree | 3 |
Package 1 Weight | 0.037 kg | |
---|---|---|
Package 1 Height | 0.410 dm | |
Package 1 width | 0.210 dm | |
Package 1 Length | 0.280 dm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
REACh free of SVHC | Yes | |
EU RoHS Directive | Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration | |
Toxic heavy metal free | Yes | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | ||
Environmental Disclosure | ||
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | |
California proposition 65 | WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Warranty | 12 months |
---|
range of product | Harmony Electromechanical Relays | |
---|---|---|
series name | Miniature | |
product or component type | Plug-in relay | |
device short name | RXM | |
contacts type and composition | 2 C/O | |
[Uc] control circuit voltage | 120 V AC 50/60 Hz | |
[Ithe] conventional enclosed thermal current | 12 A at -40…55 °C | |
status LED | With | |
control type | Lockable test button | |
utilisation coefficient | 20 % |
shape of pin | Flat | |
---|---|---|
[Ui] rated insulation voltage | 250 V conforming to IEC 300 V conforming to CSA 300 V conforming to UL | |
[Uimp] rated impulse withstand voltage | 4 kV during 1.2/50 µs | |
contacts material | AgNi | |
[Ie] rated operational current | 12 A at 28 V (DC) NO conforming to IEC 12 A at 250 V (AC) NO conforming to IEC 6 A at 28 V (DC) NC conforming to IEC 6 A at 250 V (AC) NC conforming to IEC 12 A at 28 V (DC) conforming to UL 12 A at 277 V (AC) conforming to UL | |
maximum switching voltage | 250 V conforming to IEC | |
resistive rated load | 12 A at 250 V AC 12 A at 28 V DC | |
maximum switching capacity | 3000 VA/336 W | |
minimum switching capacity | 170 mW at 10 mA, 17 V | |
operating rate | <= 1200 cycles/hour under load <= 18000 cycles/hour no-load | |
mechanical durability | 10000000 cycles | |
electrical durability | 100000 cycles for resistive load | |
average coil consumption in VA | 1.2 at 60 Hz | |
average consumption | 1.2 VA at 60 Hz | |
drop-out voltage threshold | >= 0.15 Uc | |
operate time | 20 ms | |
release time | 20 ms | |
average coil resistance | 3630 Ohm at 20 °C +/- 15 % | |
rated operational voltage limits | 96...132 V AC | |
safety reliability data | B10d = 100000 | |
protection category | RT I | |
test levels | Level A group mounting | |
operating position | Any position | |
CAD overall height | 79 mm | |
CAD overall depth | 78.45 mm | |
net weight | 0.037 kg | |
device presentation | Complete product |
dielectric strength | 1300 V AC between contacts with micro disconnection 2000 V AC between coil and contact 2000 V AC between poles | |
---|---|---|
product certifications | GOST CSA UL Lloyd's CE | |
standards | CSA C22.2 No 14 EN/IEC 61810-1 UL 508 | |
ambient air temperature for storage | -40…85 °C | |
ambient air temperature for operation | -40…55 °C | |
vibration resistance | 3 gn, amplitude = +/- 1 mm (f = 10…150 Hz)5 cycles in operation 5 gn, amplitude = +/- 1 mm (f = 10…150 Hz)5 cycles not operating | |
IP degree of protection | IP40 conforming to EN/IEC 60529 | |
shock resistance | 10 gn for in operation 30 gn for not operating | |
pollution degree | 3 |
Package 1 Weight | 0.037 kg | |
---|---|---|
Package 1 Height | 0.410 dm | |
Package 1 width | 0.210 dm | |
Package 1 Length | 0.280 dm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
REACh free of SVHC | Yes | |
EU RoHS Directive | Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration | |
Toxic heavy metal free | Yes | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | ||
Environmental Disclosure | ||
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | |
California proposition 65 | WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Warranty | 12 months |
---|
Recently Viewed Products
Schneider Miniature Plug-in relay - Zelio RXM 2 C/O 120 V AC 12 A with LED
Rp 160,062.00