Spesifikasi
range | ComPact | |
---|---|---|
product name | ComPact NS | |
range of product | ComPact NS630b...1600 | |
device short name | Compact NS1600N | |
product or component type | Circuit breaker | |
device application | Distribution | |
Number of poles | 3P | |
protected poles description | 3d | |
(In) rated current up to 65 °C | 1600 A at 50 °C | |
[Ue] rated operational voltage | 690 V AC 50/60 Hz | |
network type | AC | |
network frequency | 50/60 Hz | |
suitability for isolation | Yes conforming to EN/IEC 60947-2 | |
utilisation category | Category B | |
[Icu] rated ultimate short-circuit breaking capacity | 30 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 | |
Performance level | N 50 kA 415 V AC | |
trip unit name | Micrologic 2.0 | |
trip unit technology | Electronic | |
trip unit protection functions | LI | |
control type | Toggle Rotary handle | |
Circuit breaker mounting mode | Fixed |
[Ui] rated insulation voltage | 800 V AC 50/60 Hz conforming to IEC 60947-2 | |
---|---|---|
[Uimp] rated impulse withstand voltage | 8 kV conforming to IEC 60947-2 | |
[Ics] rated service short-circuit breaking capacity | 30 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 37 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 37 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 22 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 37 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 | |
[Icw] rated short-time withstand current | 19.2 kA 1 s conforming to IEC 60947-2 | |
mechanical durability | 10000 cycles | |
electrical durability | 1000 cycles at 690 V In 2000 cycles at 690 V In/2 2000 cycles at 440 V In 5000 cycles at 440 V In/2 | |
power losses | 74 W | |
mounting support | Backplate | |
upside connection | Front | |
downside connection | Front | |
connection pitch | 70 mm | |
protection type | L : for overload protection (long time) I : for instantaneous short-circuit protection | |
trip unit rating | 1600 A at 50 °C | |
Long-time pick-up adjustment type Ir (thermal protection) | Adjustable 9 settings | |
[Ir] long-time protection pick-up adjustment range | 0.4...1 x In | |
Long-time protection delay adjustment type tr | Adjustable 9 settings | |
[tr] long-time protection delay adjustment range | 12.5…600 s at 1.5 x Ir 0.5…24 s at 6 x Ir 0.7…16.6 s at 7.2 x Ir | |
thermal memory | 20 mn | |
Instantaneous protection pick-up adjustment type Ii | Adjustable | |
[Ii] instantaneous protection pick-up adjustment range | 1.5...10 x Ir | |
earth-leakage protection | Without | |
auxiliary contact composition | 1 NO/NC | |
local signalling | 4 LEDs (red) for fault indication 1 LED (yellow) for overload | |
Width (W) | 210 mm | |
Height (H) | 327 mm | |
Depth (D) | 147 mm | |
net weight | 14 kg |
standards | EN/IEC 60947-2 | |
---|---|---|
product certifications | ASTA ASEFA | |
pollution degree | 3 conforming to IEC 60947 | |
IP degree of protection | IP40 conforming to IEC 60529 | |
IK degree of protection | IK07 conforming to EN 50102 | |
ambient air temperature for operation | -25…70 °C | |
ambient air temperature for storage | -50…85 °C | |
relative humidity | 0…95 % | |
operating altitude | 0...2000 m without derating 2000 m...5000 m with derating |
Unit Type of Package 1 | PCE | |
---|---|---|
Number of Units in Package 1 | 1 | |
Package 1 Weight | 14 kg | |
Package 1 Height | 30 cm | |
Package 1 width | 40 cm | |
Package 1 Length | 60 cm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
EU RoHS Directive | Compliant EU RoHS Declaration | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | China RoHS declaration Product out of China RoHS scope. Substance declaration for your information | |
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Warranty | 12 months |
---|
Specifications for Schneider NS1600N 3P 1600A MICROLOGIC 2.0
# of Pole | 3 |
Arus Nominal (In) | 1600A |
range | ComPact | |
---|---|---|
product name | ComPact NS | |
range of product | ComPact NS630b...1600 | |
device short name | Compact NS1600N | |
product or component type | Circuit breaker | |
device application | Distribution | |
Number of poles | 3P | |
protected poles description | 3d | |
(In) rated current up to 65 °C | 1600 A at 50 °C | |
[Ue] rated operational voltage | 690 V AC 50/60 Hz | |
network type | AC | |
network frequency | 50/60 Hz | |
suitability for isolation | Yes conforming to EN/IEC 60947-2 | |
utilisation category | Category B | |
[Icu] rated ultimate short-circuit breaking capacity | 30 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 | |
Performance level | N 50 kA 415 V AC | |
trip unit name | Micrologic 2.0 | |
trip unit technology | Electronic | |
trip unit protection functions | LI | |
control type | Toggle Rotary handle | |
Circuit breaker mounting mode | Fixed |
[Ui] rated insulation voltage | 800 V AC 50/60 Hz conforming to IEC 60947-2 | |
---|---|---|
[Uimp] rated impulse withstand voltage | 8 kV conforming to IEC 60947-2 | |
[Ics] rated service short-circuit breaking capacity | 30 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 37 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 37 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 22 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 37 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 | |
[Icw] rated short-time withstand current | 19.2 kA 1 s conforming to IEC 60947-2 | |
mechanical durability | 10000 cycles | |
electrical durability | 1000 cycles at 690 V In 2000 cycles at 690 V In/2 2000 cycles at 440 V In 5000 cycles at 440 V In/2 | |
power losses | 74 W | |
mounting support | Backplate | |
upside connection | Front | |
downside connection | Front | |
connection pitch | 70 mm | |
protection type | L : for overload protection (long time) I : for instantaneous short-circuit protection | |
trip unit rating | 1600 A at 50 °C | |
Long-time pick-up adjustment type Ir (thermal protection) | Adjustable 9 settings | |
[Ir] long-time protection pick-up adjustment range | 0.4...1 x In | |
Long-time protection delay adjustment type tr | Adjustable 9 settings | |
[tr] long-time protection delay adjustment range | 12.5…600 s at 1.5 x Ir 0.5…24 s at 6 x Ir 0.7…16.6 s at 7.2 x Ir | |
thermal memory | 20 mn | |
Instantaneous protection pick-up adjustment type Ii | Adjustable | |
[Ii] instantaneous protection pick-up adjustment range | 1.5...10 x Ir | |
earth-leakage protection | Without | |
auxiliary contact composition | 1 NO/NC | |
local signalling | 4 LEDs (red) for fault indication 1 LED (yellow) for overload | |
Width (W) | 210 mm | |
Height (H) | 327 mm | |
Depth (D) | 147 mm | |
net weight | 14 kg |
standards | EN/IEC 60947-2 | |
---|---|---|
product certifications | ASTA ASEFA | |
pollution degree | 3 conforming to IEC 60947 | |
IP degree of protection | IP40 conforming to IEC 60529 | |
IK degree of protection | IK07 conforming to EN 50102 | |
ambient air temperature for operation | -25…70 °C | |
ambient air temperature for storage | -50…85 °C | |
relative humidity | 0…95 % | |
operating altitude | 0...2000 m without derating 2000 m...5000 m with derating |
Unit Type of Package 1 | PCE | |
---|---|---|
Number of Units in Package 1 | 1 | |
Package 1 Weight | 14 kg | |
Package 1 Height | 30 cm | |
Package 1 width | 40 cm | |
Package 1 Length | 60 cm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
EU RoHS Directive | Compliant EU RoHS Declaration | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | China RoHS declaration Product out of China RoHS scope. Substance declaration for your information | |
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Warranty | 12 months |
---|