Spesifikasi
| range of product | Harmony Timer Relays | |
|---|---|---|
| product or component type | Single function relay | |
| fixing mode | Plug-in (socket) | |
| discrete output type | Relay | |
| contacts type and composition | 4 C/O | |
| component name | REXL | |
| time delay type | Power on-delay | |
| time delay range | 6...60 s 1...10 s 6...60 min 1...10 min 0.1...1 s 10...100 h 1...10 h |
| contacts material | Cadmium free | |
|---|---|---|
| [Us] rated supply voltage | 230 V AC 50/60 Hz | |
| voltage range | 0.85...1.15 Us | |
| [In] rated current | 5 A AC | |
| repeat accuracy | +/- 0.5 % | |
| setting accuracy of time delay | 10 % at full scale at 25 °C conforming to EN/IEC 61812-1 | |
| temperature drift | 0.05 %/°C | |
| maximum reset time | 250 ms after time delay, on de-energisation 50 ms during time delay, on de-energisation | |
| voltage drift | +/- 0.2 %/V | |
| maximum switching capacity | 4 x 5 A | |
| maximum temporary permissible current | 10 A for < 10 s | |
| minimum switching current | 100 mA | |
| electrical durability | 100000 cycles at 250 V AC resistive | |
| mechanical durability | 10000000 cycles | |
| maximum power consumption | 3 VA | |
| [Ui] rated insulation voltage | 250 V conforming to IEC 255 Group C 250 V conforming to VDE 0010 | |
| output overvoltage protection | 2 J | |
| surge withstand | 2 kV conforming to EN/IEC 61000-4-5 level 3 | |
| creepage distance | 4 kV/3 conforming to IEC 60664-1 | |
| local signalling | 1 LED (red) for output in operation 1 LED (yellow) for power ON | |
| net weight | 0.05 kg |
| immunity to microbreaks | 5 ms | |
|---|---|---|
| dielectric strength | 2 kV for 1 mA/1 minute at 50 Hz conforming to EN/IEC 60601-1 2 kV for 1 mA/1 minute at 50 Hz conforming to EN/IEC 61812-1 | |
| standards | EN 61000-6-2 EN 50081-2 EN/IEC 60601-1 EN/IEC 60601-2 73/23/EEC 93/68/EEC 89/336/EEC EN/IEC 61812-1 | |
| product certifications | CUL UL | |
| ambient air temperature for operation | -20…60 °C | |
| ambient air temperature for storage | -40…70 °C | |
| IP degree of protection | IP50 conforming to IEC 60529 | |
| vibration resistance | 0.35 mm (f= 10…55 Hz) conforming to IEC 60068-2-6 | |
| relative humidity | 95 % without condensation conforming to IEC 60068-2-6 | |
| resistance to electrostatic discharge | 6 kV in contact conforming to EN/IEC 61000-4-2 level 3 8 kV in air conforming to EN/IEC 61000-4-2 level 3 | |
| resistance to electromagnetic fields | 10 V/m conforming to EN/IEC 61000-4-3 level 3 | |
| resistance to fast transients | 2 kV conforming to EN/IEC 61000-4-4 level 3 | |
| immunity to radioelectric fields | 10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6 level 3 | |
| immunity to voltage dips | >= 95 % / 1 s conforming to EN/IEC 61000-4-11 30 % / 10 ms conforming to EN/IEC 61000-4-11 60 % / 100 ms conforming to EN/IEC 61000-4-11 | |
| disturbance radiated/conducted | Class B conforming to EN 55022 (EN 55011 group 1) |
| Unit Type of Package 1 | PCE | |
|---|---|---|
| Number of Units in Package 1 | 1 | |
| Package 1 Weight | 52 g | |
| Package 1 Height | 3.1 cm | |
| Package 1 width | 3.1 cm | |
| Package 1 Length | 7.5 cm | |
| Unit Type of Package 2 | S01 | |
| Number of Units in Package 2 | 48 | |
| Package 2 Weight | 2.713 kg | |
| Package 2 Height | 15 cm | |
| Package 2 width | 15 cm | |
| Package 2 Length | 40 cm |
| Sustainable offer status | Green Premium product | |
|---|---|---|
| REACh Regulation | ||
| EU RoHS Directive | Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration | |
| Mercury free | Yes | |
| RoHS exemption information | ||
| China RoHS Regulation | ||
| Environmental Disclosure |
| Warranty | 12 months |
|---|
| range of product | Harmony Timer Relays | |
|---|---|---|
| product or component type | Single function relay | |
| fixing mode | Plug-in (socket) | |
| discrete output type | Relay | |
| contacts type and composition | 4 C/O | |
| component name | REXL | |
| time delay type | Power on-delay | |
| time delay range | 6...60 s 1...10 s 6...60 min 1...10 min 0.1...1 s 10...100 h 1...10 h |
| contacts material | Cadmium free | |
|---|---|---|
| [Us] rated supply voltage | 230 V AC 50/60 Hz | |
| voltage range | 0.85...1.15 Us | |
| [In] rated current | 5 A AC | |
| repeat accuracy | +/- 0.5 % | |
| setting accuracy of time delay | 10 % at full scale at 25 °C conforming to EN/IEC 61812-1 | |
| temperature drift | 0.05 %/°C | |
| maximum reset time | 250 ms after time delay, on de-energisation 50 ms during time delay, on de-energisation | |
| voltage drift | +/- 0.2 %/V | |
| maximum switching capacity | 4 x 5 A | |
| maximum temporary permissible current | 10 A for < 10 s | |
| minimum switching current | 100 mA | |
| electrical durability | 100000 cycles at 250 V AC resistive | |
| mechanical durability | 10000000 cycles | |
| maximum power consumption | 3 VA | |
| [Ui] rated insulation voltage | 250 V conforming to IEC 255 Group C 250 V conforming to VDE 0010 | |
| output overvoltage protection | 2 J | |
| surge withstand | 2 kV conforming to EN/IEC 61000-4-5 level 3 | |
| creepage distance | 4 kV/3 conforming to IEC 60664-1 | |
| local signalling | 1 LED (red) for output in operation 1 LED (yellow) for power ON | |
| net weight | 0.05 kg |
| immunity to microbreaks | 5 ms | |
|---|---|---|
| dielectric strength | 2 kV for 1 mA/1 minute at 50 Hz conforming to EN/IEC 60601-1 2 kV for 1 mA/1 minute at 50 Hz conforming to EN/IEC 61812-1 | |
| standards | EN 61000-6-2 EN 50081-2 EN/IEC 60601-1 EN/IEC 60601-2 73/23/EEC 93/68/EEC 89/336/EEC EN/IEC 61812-1 | |
| product certifications | CUL UL | |
| ambient air temperature for operation | -20…60 °C | |
| ambient air temperature for storage | -40…70 °C | |
| IP degree of protection | IP50 conforming to IEC 60529 | |
| vibration resistance | 0.35 mm (f= 10…55 Hz) conforming to IEC 60068-2-6 | |
| relative humidity | 95 % without condensation conforming to IEC 60068-2-6 | |
| resistance to electrostatic discharge | 6 kV in contact conforming to EN/IEC 61000-4-2 level 3 8 kV in air conforming to EN/IEC 61000-4-2 level 3 | |
| resistance to electromagnetic fields | 10 V/m conforming to EN/IEC 61000-4-3 level 3 | |
| resistance to fast transients | 2 kV conforming to EN/IEC 61000-4-4 level 3 | |
| immunity to radioelectric fields | 10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6 level 3 | |
| immunity to voltage dips | >= 95 % / 1 s conforming to EN/IEC 61000-4-11 30 % / 10 ms conforming to EN/IEC 61000-4-11 60 % / 100 ms conforming to EN/IEC 61000-4-11 | |
| disturbance radiated/conducted | Class B conforming to EN 55022 (EN 55011 group 1) |
| Unit Type of Package 1 | PCE | |
|---|---|---|
| Number of Units in Package 1 | 1 | |
| Package 1 Weight | 52 g | |
| Package 1 Height | 3.1 cm | |
| Package 1 width | 3.1 cm | |
| Package 1 Length | 7.5 cm | |
| Unit Type of Package 2 | S01 | |
| Number of Units in Package 2 | 48 | |
| Package 2 Weight | 2.713 kg | |
| Package 2 Height | 15 cm | |
| Package 2 width | 15 cm | |
| Package 2 Length | 40 cm |
| Sustainable offer status | Green Premium product | |
|---|---|---|
| REACh Regulation | ||
| EU RoHS Directive | Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration | |
| Mercury free | Yes | |
| RoHS exemption information | ||
| China RoHS Regulation | ||
| Environmental Disclosure |
| Warranty | 12 months |
|---|