Spesifikasi
range of product | Harmony XAC | |
---|---|---|
product or component type | Pendant control station | |
device short name | XACA |
control station type | Double insulated | |
---|---|---|
enclosure material | Polypropylene | |
electrical circuit type | Control circuit | |
enclosure type | Complete ready for use | |
control station application | Control of single speed hoist motor | |
control station composition | 4 push-buttons | |
control button type | First push-button 1 NC + 1 NO raise, slow Second push-button 1 NC + 1 NO lower, slow Fourth push-button 1 NC + 1 NO left, slow Third push-button 1 NC + 1 NO right, slow | |
product compatibility | ZB2BE102 + ZB2BE101 for each direction | |
mechanical interlocking | With mechanical interlocking between pairs | |
control station colour | Yellow | |
connections - terminals | Screw clamp terminals, 1 x 0.5...1 x 2.5 mm² without cable end Screw clamp terminals, 1 x 0.5...2 x 1.5 mm² with cable end | |
standards | EN/IEC 60204-32 CSA C22.2 No 14 EN/IEC 60947-5-1 UL 508 | |
product certifications | GOST CCC | |
protective treatment | TH | |
ambient air temperature for operation | -25…70 °C | |
ambient air temperature for storage | -40…70 °C | |
vibration resistance | 15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 | |
shock resistance | 100 gn conforming to IEC 60068-2-27 | |
overvoltage category | Class II conforming to IEC 61140 | |
IP degree of protection | IP65 conforming to IEC 60529 | |
IK degree of protection | IK08 conforming to EN 50102 | |
mechanical durability | 1000000 cycles | |
cable entry | Rubber sleeve with stepped entry 8…26 mm | |
contact code designation | A600 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A A600 AC-15, Ue = 600 V, Ie = 1.2 A conforming to IEC 60947-5-1 appendix A Q600 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A Q600 DC-13, Ue = 600 V, Ie = 0.1 A conforming to IEC 60947-5-1 appendix A | |
[Ithe] conventional enclosed thermal current | 10 A | |
[Ui] rated insulation voltage | 600 V (pollution degree 3) | |
[Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-1 | |
contact operation | Slow-break | |
maximum resistance across terminals | 25 MOhm | |
operating force | 13 N push-button | |
short-circuit protection | 10 A fuse protection by cartridge fuse type gG | |
rated operational power in W | 40 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 120 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C 48 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 48 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C 65 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 24 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C | |
terminals description ISO n°1 | (13-14)NO (11-12)NC | |
terminal identifier | (11-12)NC (13-14)NO | |
net weight | 0.675 kg |
Unit Type of Package 1 | PCE | |
---|---|---|
Number of Units in Package 1 | 1 | |
Package 1 Weight | 766 g | |
Package 1 Height | 8.4 cm | |
Package 1 width | 9.2 cm | |
Package 1 Length | 44.5 cm | |
Unit Type of Package 2 | P06 | |
Number of Units in Package 2 | 48 | |
Package 2 Weight | 49.77 kg | |
Package 2 Height | 80 cm | |
Package 2 width | 80 cm | |
Package 2 Length | 60 cm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
REACh free of SVHC | Yes | |
EU RoHS Directive | Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration | |
Toxic heavy metal free | Yes | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | ||
Environmental Disclosure | ||
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Warranty | 12 months |
---|
range of product | Harmony XAC | |
---|---|---|
product or component type | Pendant control station | |
device short name | XACA |
control station type | Double insulated | |
---|---|---|
enclosure material | Polypropylene | |
electrical circuit type | Control circuit | |
enclosure type | Complete ready for use | |
control station application | Control of single speed hoist motor | |
control station composition | 4 push-buttons | |
control button type | First push-button 1 NC + 1 NO raise, slow Second push-button 1 NC + 1 NO lower, slow Fourth push-button 1 NC + 1 NO left, slow Third push-button 1 NC + 1 NO right, slow | |
product compatibility | ZB2BE102 + ZB2BE101 for each direction | |
mechanical interlocking | With mechanical interlocking between pairs | |
control station colour | Yellow | |
connections - terminals | Screw clamp terminals, 1 x 0.5...1 x 2.5 mm² without cable end Screw clamp terminals, 1 x 0.5...2 x 1.5 mm² with cable end | |
standards | EN/IEC 60204-32 CSA C22.2 No 14 EN/IEC 60947-5-1 UL 508 | |
product certifications | GOST CCC | |
protective treatment | TH | |
ambient air temperature for operation | -25…70 °C | |
ambient air temperature for storage | -40…70 °C | |
vibration resistance | 15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 | |
shock resistance | 100 gn conforming to IEC 60068-2-27 | |
overvoltage category | Class II conforming to IEC 61140 | |
IP degree of protection | IP65 conforming to IEC 60529 | |
IK degree of protection | IK08 conforming to EN 50102 | |
mechanical durability | 1000000 cycles | |
cable entry | Rubber sleeve with stepped entry 8…26 mm | |
contact code designation | A600 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A A600 AC-15, Ue = 600 V, Ie = 1.2 A conforming to IEC 60947-5-1 appendix A Q600 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A Q600 DC-13, Ue = 600 V, Ie = 0.1 A conforming to IEC 60947-5-1 appendix A | |
[Ithe] conventional enclosed thermal current | 10 A | |
[Ui] rated insulation voltage | 600 V (pollution degree 3) | |
[Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-1 | |
contact operation | Slow-break | |
maximum resistance across terminals | 25 MOhm | |
operating force | 13 N push-button | |
short-circuit protection | 10 A fuse protection by cartridge fuse type gG | |
rated operational power in W | 40 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 120 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C 48 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 48 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C 65 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 24 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C | |
terminals description ISO n°1 | (13-14)NO (11-12)NC | |
terminal identifier | (11-12)NC (13-14)NO | |
net weight | 0.675 kg |
Unit Type of Package 1 | PCE | |
---|---|---|
Number of Units in Package 1 | 1 | |
Package 1 Weight | 766 g | |
Package 1 Height | 8.4 cm | |
Package 1 width | 9.2 cm | |
Package 1 Length | 44.5 cm | |
Unit Type of Package 2 | P06 | |
Number of Units in Package 2 | 48 | |
Package 2 Weight | 49.77 kg | |
Package 2 Height | 80 cm | |
Package 2 width | 80 cm | |
Package 2 Length | 60 cm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
REACh free of SVHC | Yes | |
EU RoHS Directive | Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration | |
Toxic heavy metal free | Yes | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | ||
Environmental Disclosure | ||
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Warranty | 12 months |
---|