• Sign up now and get discount up to 47%

Schneider Phase control relay RM17-T - range 183..484 V AC

Rp 1,164,451.00 Rp 675,381.00 675381 IDR

Rp 1,164,451.00

Option not available

    This combination does not exist.

    Add to Cart

    Schneider Phase control relay RM17-T - range 183..484 V AC
    Terjual 0
    0 (0 Rating)
    Ulasan (0)

    Rp 675,381.00
    42.00 % Rp 1,164,451.00 675381 IDR

    Rp 1,164,451.00

    Option not available

    Atur Jumlah & Catatan
    Stock Total: 46
    Spesifikasi
    Main (see above)
    range of product
    Harmony Control Relays
    product or component type
    3-phase control relay
    relay type
    Control relay
    product specific application
    For 3-phase supply
    relay name
    RM17TG
    relay monitored parameters
    Phase sequence
    Phase failure detection (2 or more phase cut)
    time delay
    Without
    switching capacity in VA
    1250 VA
    measurement range
    208...440 V voltage AC
    contacts type and composition
    2 C/O
    [Uc] control circuit voltage
    208...440 V
    Complementary (see above)
    maximum switching voltage
    250 V AC
    250 V DC
    minimum switching current
    10 mA at 5 V DC
    supply voltage limits
    183…484 V AC
    control circuit voltage limits
    - 12 % + 10 % Un
    power consumption in VA
    0…22 VA at 400 V AC 50 Hz
    voltage detection threshold
    < 100 V AC
    control circuit frequency
    50...60 Hz +/- 10 %
    output contacts
    2 C/O
    nominal output current
    5 A
    measurement voltage limits
    183…484 V AC
    delay at power up
    650 ms
    voltage range
    183...484 V
    response time
    <= 130 ms (in the event of a fault)
    marking
    CE
    overvoltage category
    III conforming to IEC 60664-1
    insulation resistance
    > 500 MOhm at 500 V DC conforming to IEC 60255-5
    > 500 MOhm at 500 V DC conforming to IEC 60664-1
    [Ui] rated insulation voltage
    400 V conforming to IEC 60664-1
    supply frequency
    50/60 Hz +/- 10 %
    operating position
    Any position without derating
    connections - terminals
    Screw terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable end
    Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end
    Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) flexible with cable end
    Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
    tightening torque
    0.6…1 N.m conforming to IEC 60947-1
    housing material
    Self-extinguishing plastic
    local signalling
    LED (yellow) for relay ON
    mounting support
    35 mm symmetrical DIN rail conforming to EN/IEC 60715
    electrical durability
    10000 cycles
    mechanical durability
    30000000 cycles
    operating rate
    <= 360 operations/hour full load
    utilisation category
    AC-12 conforming to IEC 60947-5-1
    AC-13 conforming to IEC 60947-5-1
    AC-14 conforming to IEC 60947-5-1
    AC-15 conforming to IEC 60947-5-1
    DC-12 conforming to IEC 60947-5-1
    DC-13 conforming to IEC 60947-5-1
    safety reliability data
    B10d = 850000
    MTTFd = 924.6 years
    width
    17.5 mm
    net weight
    0.13 kg
    Environment (see above)
    electromagnetic compatibility
    Emission standard for industrial environments conforming to EN/IEC 61000-6-4
    Emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3
    Immunity for industrial environments conforming to EN/IEC 61000-6-2
    standards
    EN/IEC 60255-1
    product certifications
    GOST
    C-Tick
    UL
    CSA
    GL
    directives
    73/23/EEC - low voltage directive
    89/336/EEC - electromagnetic compatibility
    ambient air temperature for storage
    -40…70 °C
    ambient air temperature for operation
    -20…50 °C
    relative humidity
    95 % at 55 °C conforming to IEC 60068-2-30
    vibration resistance
    0.35 mm (f= 5…57.6 Hz) conforming to IEC 60068-2-6
    1 gn (f= 57.6…150 Hz) conforming to IEC 60255-21-1
    shock resistance
    15 gn for 11 ms conforming to IEC 60255-21-1
    IP degree of protection
    IP20 (terminals) conforming to IEC 60529
    IP30 (casing) conforming to IEC 60529
    pollution degree
    3 conforming to IEC 60664-1
    dielectric test voltage
    2 kV, 1 min AC 50 Hz
    non-dissipating shock wave
    4 kV
    Packing Units (see above)
    Unit Type of Package 1
    PCE
    Number of Units in Package 1
    1
    Package 1 Weight
    93 g
    Package 1 Height
    2.7 cm
    Package 1 width
    7.8 cm
    Package 1 Length
    9.7 cm
    Unit Type of Package 2
    S02
    Number of Units in Package 2
    48
    Package 2 Weight
    4.909 kg
    Package 2 Height
    15 cm
    Package 2 width
    30 cm
    Package 2 Length
    40 cm
    Unit Type of Package 3
    P06
    Number of Units in Package 3
    768
    Package 3 Weight
    87.204 kg
    Package 3 Height
    77 cm
    Package 3 width
    80 cm
    Package 3 Length
    60 cm
    Offer Sustainability (see above)
    Sustainable offer status
    Green Premium product
    REACh Regulation
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
    Contractual warranty (see above)
    Warranty
    12 months

    Filter By

    Product Public Price Discount Guaranteed Stock QTY Action
    Rp 60,674.00 100.00 % 12
    Rp 58,552.00 100.00 % 357
    Rp 54,640.00 100.00 % 68
    Rp 49,335.00 100.00 % 599
    Rp 50,065.00 100.00 % 54
    Rp 47,544.00 100.00 % 372
    Main (see above)
    range of product
    Harmony Control Relays
    product or component type
    3-phase control relay
    relay type
    Control relay
    product specific application
    For 3-phase supply
    relay name
    RM17TG
    relay monitored parameters
    Phase sequence
    Phase failure detection (2 or more phase cut)
    time delay
    Without
    switching capacity in VA
    1250 VA
    measurement range
    208...440 V voltage AC
    contacts type and composition
    2 C/O
    [Uc] control circuit voltage
    208...440 V
    Complementary (see above)
    maximum switching voltage
    250 V AC
    250 V DC
    minimum switching current
    10 mA at 5 V DC
    supply voltage limits
    183…484 V AC
    control circuit voltage limits
    - 12 % + 10 % Un
    power consumption in VA
    0…22 VA at 400 V AC 50 Hz
    voltage detection threshold
    < 100 V AC
    control circuit frequency
    50...60 Hz +/- 10 %
    output contacts
    2 C/O
    nominal output current
    5 A
    measurement voltage limits
    183…484 V AC
    delay at power up
    650 ms
    voltage range
    183...484 V
    response time
    <= 130 ms (in the event of a fault)
    marking
    CE
    overvoltage category
    III conforming to IEC 60664-1
    insulation resistance
    > 500 MOhm at 500 V DC conforming to IEC 60255-5
    > 500 MOhm at 500 V DC conforming to IEC 60664-1
    [Ui] rated insulation voltage
    400 V conforming to IEC 60664-1
    supply frequency
    50/60 Hz +/- 10 %
    operating position
    Any position without derating
    connections - terminals
    Screw terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable end
    Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end
    Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) flexible with cable end
    Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
    tightening torque
    0.6…1 N.m conforming to IEC 60947-1
    housing material
    Self-extinguishing plastic
    local signalling
    LED (yellow) for relay ON
    mounting support
    35 mm symmetrical DIN rail conforming to EN/IEC 60715
    electrical durability
    10000 cycles
    mechanical durability
    30000000 cycles
    operating rate
    <= 360 operations/hour full load
    utilisation category
    AC-12 conforming to IEC 60947-5-1
    AC-13 conforming to IEC 60947-5-1
    AC-14 conforming to IEC 60947-5-1
    AC-15 conforming to IEC 60947-5-1
    DC-12 conforming to IEC 60947-5-1
    DC-13 conforming to IEC 60947-5-1
    safety reliability data
    B10d = 850000
    MTTFd = 924.6 years
    width
    17.5 mm
    net weight
    0.13 kg
    Environment (see above)
    electromagnetic compatibility
    Emission standard for industrial environments conforming to EN/IEC 61000-6-4
    Emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3
    Immunity for industrial environments conforming to EN/IEC 61000-6-2
    standards
    EN/IEC 60255-1
    product certifications
    GOST
    C-Tick
    UL
    CSA
    GL
    directives
    73/23/EEC - low voltage directive
    89/336/EEC - electromagnetic compatibility
    ambient air temperature for storage
    -40…70 °C
    ambient air temperature for operation
    -20…50 °C
    relative humidity
    95 % at 55 °C conforming to IEC 60068-2-30
    vibration resistance
    0.35 mm (f= 5…57.6 Hz) conforming to IEC 60068-2-6
    1 gn (f= 57.6…150 Hz) conforming to IEC 60255-21-1
    shock resistance
    15 gn for 11 ms conforming to IEC 60255-21-1
    IP degree of protection
    IP20 (terminals) conforming to IEC 60529
    IP30 (casing) conforming to IEC 60529
    pollution degree
    3 conforming to IEC 60664-1
    dielectric test voltage
    2 kV, 1 min AC 50 Hz
    non-dissipating shock wave
    4 kV
    Packing Units (see above)
    Unit Type of Package 1
    PCE
    Number of Units in Package 1
    1
    Package 1 Weight
    93 g
    Package 1 Height
    2.7 cm
    Package 1 width
    7.8 cm
    Package 1 Length
    9.7 cm
    Unit Type of Package 2
    S02
    Number of Units in Package 2
    48
    Package 2 Weight
    4.909 kg
    Package 2 Height
    15 cm
    Package 2 width
    30 cm
    Package 2 Length
    40 cm
    Unit Type of Package 3
    P06
    Number of Units in Package 3
    768
    Package 3 Weight
    87.204 kg
    Package 3 Height
    77 cm
    Package 3 width
    80 cm
    Package 3 Length
    60 cm
    Offer Sustainability (see above)
    Sustainable offer status
    Green Premium product
    REACh Regulation
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
    Contractual warranty (see above)
    Warranty
    12 months