• Sign up now and get discount up to 47%

Schneider Schneider Electric TeSys D Kontaktor 3P 95A 45KW 1 NO 1 NC 380V AC Coil - LC1D95Q7

# of Pole : 3

P (kW) : 45

[Ie] rated operational current : 95

Rp 4,229,066.00 Rp 2,368,276.00 2368276 IDR

Rp 4,229,066.00

Option not available

  • # of Pole
  • P (kW)
  • [Ie] rated operational current

This combination does not exist.

Add to Cart

Schneider Schneider Electric TeSys D Kontaktor 3P 95A 45KW 1 NO 1 NC 380V AC Coil - LC1D95Q7
Terjual 0
0 (0 Rating)
Ulasan (0)

Rp 2,368,276.00
44.00 % Rp 4,229,066.00 2368276 IDR

Rp 4,229,066.00

Option not available

Atur Jumlah & Catatan
Stock Total: 2

# of Pole : 3

P (kW) : 45

[Ie] rated operational current : 95

Spesifikasi

[Deskripsi] 1. product name : TeSys D 2. product or component type : Contactor 3. device short name : LC1D 4. contactor application : -Motor Control -Resistive load 5. utilisation category : -AC-4 -AC-1 -AC-3 6. poles description : 3P 7. power pole contact composition : 3 NO 8. [Ue] rated operational voltage : -Power circuit: <= 690 V AC 25...400 Hz -Power circuit: <= 300 V DC 9. [Ie] rated operational current : -125 A (at <60 °C) at <= 440 V AC AC-1 for power circuit -95 A (at <60 °C) at <= 440 V AC AC-3 for power circuit 10.motor power kW : -45 kW at 415...440 V AC 50/60 Hz (AC-3) -55 kW at 500 V AC 50/60 Hz (AC-3) -45 kW at 660...690 V AC 50/60 Hz (AC-3) -45 kW at 1000 V AC 50/60 Hz (AC-3) -15 kW at 400 V AC 50/60 Hz (AC-4) -25 kW at 220...230 V AC 50/60 Hz (AC-3) -45 kW at 380...400 V AC 50/60 Hz (AC-3) 11. motor power HP (UL / CSA) : -20 hp at 200/208 V AC 50/60 Hz for 3 phases motors -7.5 hp at 115 V AC 50/60 Hz for 1 phase motors -15 hp at 230/240 V AC 50/60 Hz for 1 phase motors -25 hp at 230/240 V AC 50/60 Hz for 3 phases motors -60 hp at 460/480 V AC 50/60 Hz for 3 phases motors -60 hp at 575/600 V AC 50/60 Hz for 3 phases motors 12. control circuit type : AC at 50/60 Hz 13. [Uc] control circuit voltage : 230V AC 50/60 Hz 14. auxiliary contact composition : 1 NO + 1 NC 15. [Uimp] rated impulse withstand voltage : 8 kV conforming to IEC 60947 16. overvoltage category : III 17. [Ith] conventional free air thermal current : -25 A (at 60 °C) for power circuit -10 A (at 60 °C) for signalling circuit 18. Irms rated making capacity : -250 A at 440 V for power circuit conforming to IEC 60947 -140 A AC for signalling circuit conforming to IEC 60947-5-1 -250 A DC for signalling circuit conforming to IEC 60947-5-1 19. rated breaking capacity : 250 A at 440 V for power circuit conforming to IEC 60947 20. [Icw] rated short-time withstand current : -105 A 40 °C - 10 s for power circuit -210 A 40 °C - 1 s for power circuit -30 A 40 °C - 10 min for power circuit -61 A 40 °C - 1 min for power circuit -100 A - 1 s for signalling circuit -120 A - 500 ms for signalling circuit -140 A - 100 ms for signalling circuit 21. associated fuse rating : -10 A gG for signalling circuit conforming to IEC 60947-5-1 -25 A gG at <= 690 V coordination type 1 for power circuit -20 A gG at <= 690 V coordination type 2 for power circuit 22. average impedance : 2.5 mOhm - Ith 25 A 50 Hz for power circuit 23. [Ui] rated insulation voltage : -Power circuit: 690 V conforming to IEC 60947-4-1 -Power circuit: 600 V CSA certified -Power circuit: 600 V UL certified -Signalling circuit: 690 V conforming to IEC 60947-1 -Signalling circuit: 600 V CSA certified -Signalling circuit: 600 V UL certified 24. electrical durability : -0.6 Mcycles 25 A AC-1 at Ue <= 440 V -2 Mcycles 9 A AC-3 at Ue <= 440 V 25. power dissipation per pole : -1.56 W AC-1 -0.2 W AC-3 26. safety cover : With 27. mounting support : -Plate -RaiL 28. standards : -CSA C22.2 No 14 -EN 60947-4-1 -EN 60947-5-1 -IEC 60947-4-1 -IEC 60947-5-1 -UL 508 29. product certifications : -DNV -UL -LROS (Lloyds register of shipping) -CSA -CCC -GL -GOST -RINA -BV 30. coil technology : Built-in bidirectional peak limiting diode suppressor 31. control circuit voltage limits : -Drop-out: 0.1...0.25 Uc DC (at 60 °C) -Operational: 0.7...1.25 Uc DC (at 60 °C) 32. time constant : 28 ms 33. inrush power in W : 5.4 W (at 20 °C) 34. hold-in power consumption in W : 5.4 W at 20 °C 35. auxiliary contacts type : -type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 -type mirror contact 1 NC conforming to IEC 60947-4-1 36. signalling circuit frequency : 25...400 Hz 37. minimum switching current : 5 mA for signalling circuit 38. minimum switching voltage : 17 V for signalling circuit 39. non-overlap time : -1.5 ms on de-energisation between NC and NO contact -1.5 ms on energisation between NC and NO contact 40. insulation resistance : > 10 MOhm for signalling circuit 41. height : 127 mm 42. width : 85 mm 43. depth : 130 mm 44. product weight : 1.61 kg

Specifications for Schneider Schneider Electric TeSys D Kontaktor 3P 95A 45KW 1 NO 1 NC 380V AC Coil - LC1D95Q7

# of Pole 3
P (kW) 45
[Ie] rated operational current 95

Filter By

Product Public Price Discount Guaranteed Stock QTY Action
Rp 1,026,957.00 100.00 % 14
  • # of Pole
  • P (kW)
  • Icu (kA)
Rp 901,468.00 100.00 % 15
  • # of Pole
  • P (kW)
  • Icu (kA)
Rp 860,493.00 100.00 % 15
  • # of Pole
  • P (kW)
  • Icu (kA)
Rp 754,852.00 100.00 % 15
  • # of Pole
  • P (kW)
  • Icu (kA)
Rp 754,852.00 100.00 % 15
  • # of Pole
  • P (kW)
  • Icu (kA)
Rp 754,852.00 100.00 % 15
  • # of Pole
  • P (kW)
  • Icu (kA)
HOT PROMO

[Deskripsi] 1. product name : TeSys D 2. product or component type : Contactor 3. device short name : LC1D 4. contactor application : -Motor Control -Resistive load 5. utilisation category : -AC-4 -AC-1 -AC-3 6. poles description : 3P 7. power pole contact composition : 3 NO 8. [Ue] rated operational voltage : -Power circuit: <= 690 V AC 25...400 Hz -Power circuit: <= 300 V DC 9. [Ie] rated operational current : -125 A (at <60 °C) at <= 440 V AC AC-1 for power circuit -95 A (at <60 °C) at <= 440 V AC AC-3 for power circuit 10.motor power kW : -45 kW at 415...440 V AC 50/60 Hz (AC-3) -55 kW at 500 V AC 50/60 Hz (AC-3) -45 kW at 660...690 V AC 50/60 Hz (AC-3) -45 kW at 1000 V AC 50/60 Hz (AC-3) -15 kW at 400 V AC 50/60 Hz (AC-4) -25 kW at 220...230 V AC 50/60 Hz (AC-3) -45 kW at 380...400 V AC 50/60 Hz (AC-3) 11. motor power HP (UL / CSA) : -20 hp at 200/208 V AC 50/60 Hz for 3 phases motors -7.5 hp at 115 V AC 50/60 Hz for 1 phase motors -15 hp at 230/240 V AC 50/60 Hz for 1 phase motors -25 hp at 230/240 V AC 50/60 Hz for 3 phases motors -60 hp at 460/480 V AC 50/60 Hz for 3 phases motors -60 hp at 575/600 V AC 50/60 Hz for 3 phases motors 12. control circuit type : AC at 50/60 Hz 13. [Uc] control circuit voltage : 230V AC 50/60 Hz 14. auxiliary contact composition : 1 NO + 1 NC 15. [Uimp] rated impulse withstand voltage : 8 kV conforming to IEC 60947 16. overvoltage category : III 17. [Ith] conventional free air thermal current : -25 A (at 60 °C) for power circuit -10 A (at 60 °C) for signalling circuit 18. Irms rated making capacity : -250 A at 440 V for power circuit conforming to IEC 60947 -140 A AC for signalling circuit conforming to IEC 60947-5-1 -250 A DC for signalling circuit conforming to IEC 60947-5-1 19. rated breaking capacity : 250 A at 440 V for power circuit conforming to IEC 60947 20. [Icw] rated short-time withstand current : -105 A 40 °C - 10 s for power circuit -210 A 40 °C - 1 s for power circuit -30 A 40 °C - 10 min for power circuit -61 A 40 °C - 1 min for power circuit -100 A - 1 s for signalling circuit -120 A - 500 ms for signalling circuit -140 A - 100 ms for signalling circuit 21. associated fuse rating : -10 A gG for signalling circuit conforming to IEC 60947-5-1 -25 A gG at <= 690 V coordination type 1 for power circuit -20 A gG at <= 690 V coordination type 2 for power circuit 22. average impedance : 2.5 mOhm - Ith 25 A 50 Hz for power circuit 23. [Ui] rated insulation voltage : -Power circuit: 690 V conforming to IEC 60947-4-1 -Power circuit: 600 V CSA certified -Power circuit: 600 V UL certified -Signalling circuit: 690 V conforming to IEC 60947-1 -Signalling circuit: 600 V CSA certified -Signalling circuit: 600 V UL certified 24. electrical durability : -0.6 Mcycles 25 A AC-1 at Ue <= 440 V -2 Mcycles 9 A AC-3 at Ue <= 440 V 25. power dissipation per pole : -1.56 W AC-1 -0.2 W AC-3 26. safety cover : With 27. mounting support : -Plate -RaiL 28. standards : -CSA C22.2 No 14 -EN 60947-4-1 -EN 60947-5-1 -IEC 60947-4-1 -IEC 60947-5-1 -UL 508 29. product certifications : -DNV -UL -LROS (Lloyds register of shipping) -CSA -CCC -GL -GOST -RINA -BV 30. coil technology : Built-in bidirectional peak limiting diode suppressor 31. control circuit voltage limits : -Drop-out: 0.1...0.25 Uc DC (at 60 °C) -Operational: 0.7...1.25 Uc DC (at 60 °C) 32. time constant : 28 ms 33. inrush power in W : 5.4 W (at 20 °C) 34. hold-in power consumption in W : 5.4 W at 20 °C 35. auxiliary contacts type : -type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 -type mirror contact 1 NC conforming to IEC 60947-4-1 36. signalling circuit frequency : 25...400 Hz 37. minimum switching current : 5 mA for signalling circuit 38. minimum switching voltage : 17 V for signalling circuit 39. non-overlap time : -1.5 ms on de-energisation between NC and NO contact -1.5 ms on energisation between NC and NO contact 40. insulation resistance : > 10 MOhm for signalling circuit 41. height : 127 mm 42. width : 85 mm 43. depth : 130 mm 44. product weight : 1.61 kg