Schneider TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 60 A - 48 V AC 50/60 Hz coil
# of Pole : 4
Arus Pengenal (A) : 60A
Coil AC : 48V (E7)
Rp 1,963,640.00
44.00 %
Rp 3,506,501.00
Rp 3,506,501.00
Option not available
[Deskripsi] 1. product name : TeSys D 2. product or component type : Contactor 3. device short name : LC1D 4. contactor application : Resistive load 5. utilisation category : AC-1 6. poles description : 4P 7. power pole contact composition : 4 NO 8. [Ue] rated operational voltage : -Power circuit: <= 690 V AC 25...400 Hz -Power circuit: <= 300 V DC 9. [Ie] rated operational current : 60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit 10. control circuit type : AC at 50/60 Hz 11. [Uc] control circuit voltage : 48 V AC 50/60 Hz 12. auxiliary contact composition : 1 NO + 1 NC 13. [Uimp] rated impulse withstand voltage : 6 kV conforming to IEC 60947 14. overvoltage category : III 15. [Ith] conventional free air thermal current : -10 A (at 60 °C) for signalling circuit -60 A (at 60 °C) for power circuit 16. Irms rated making capacity : -140 A AC for signalling circuit conforming to IEC 60947-5-1 -250 A DC for signalling circuit conforming to IEC 60947-5-1 -800 A at 440 V for power circuit conforming to IEC 60947 17. rated breaking capacity : 800 A at 440 V for power circuit conforming to IEC 60947 18. [Icw] rated short-time withstand current : -320 A 40 °C - 10 s for power circuit -720 A 40 °C - 1 s for power circuit -72 A 40 °C - 10 min for power circuit -165 A 40 °C - 1 min for power circuit -100 A - 1 s for signalling circuit -120 A - 500 ms for signalling circuit -140 A - 100 ms for signalling circuit 19. associated fuse rating : -10 A gG for signalling circuit conforming to IEC 60947-5-1 -80 A gG at <= 690 V coordination type 1 for power circuit -80 A gG at <= 690 V coordination type 2 for power circuit 20. average impedance : 1.6 mOhm - Ith 60 A 50 Hz for power circuit 21. [Ui] rated insulation voltage : -Power circuit: 600 V CSA certified -Power circuit: 600 V UL certified -Signalling circuit: 690 V conforming to IEC 60947-1 -Signalling circuit: 600 V CSA certified -Signalling circuit: 600 V UL certified -Power circuit: 690 V conforming to IEC 60947-4-1 22. electrical durability : 1.4 Mcycles 60 A AC-1 at Ue <= 440 V 23. power dissipation per pole : 5.8 W AC-1 24. safety cover : With 25. mounting support : -Rail -Plate 26. standards : -CSA C22.2 No 14 -EN 60947-4-1 -EN 60947-5-1 -IEC 60947-4-1 -IEC 60947-5-1 -UL 508 27. product certifications : -GOST -BV -UL -CCC -GL -CSA -RINA -LROS (Lloyds register of shipping) -DNV 28. coil technology : Without built-in suppressor module 29. control circuit voltage limits : -Drop-out: 0.3...0.6 Uc AC 50/60 Hz (at 60 °C) -Operational: 0.8...1.1 Uc AC 50 Hz (at 60 °C) -Operational: 0.85...1.1 Uc AC 60 Hz (at 60 °C) 30. inrush power in VA : -140 VA 60 Hz cos phi 0.75 (at 20 °C) -160 VA 50 Hz cos phi 0.75 (at 20 °C) 31. hold-in power consumption in VA : -13 VA 60 Hz cos phi 0.3 (at 20 °C) -15 VA 50 Hz cos phi 0.3 (at 20 °C) 32. heat dissipation : 4…5 W at 50/60 Hz 33. auxiliary contacts type : -type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 -type mirror contact 1 NC conforming to IEC 60947-4-1 34. signalling circuit frequency : 25...400 Hz 35. minimum switching current : 5 mA for signalling circuit 36. minimum switching voltage : 17 V for signalling circuit 37. non-overlap time : -1.5 ms on de-energisation between NC and NO contact -1.5 ms on energisation between NC and NO contact 38. insulation resistance : > 10 MOhm for signalling circuit 39. IP degree of protection : IP20 front face conforming to IEC 60529 40. protective treatment : TH conforming to IEC 60068-2-30 41. pollution degree : 3 42. ambient air temperature for operation : -5…60 °C 43. ambient air temperature for storage : -60…80 °C 44. permissible ambient air temperature around the device : -40…70 °C at Uc 45. operating altitude : 3000 m without 46. fire resistance : 850 °C conforming to IEC 60695-2-1 47. flame retardance : V1 conforming to UL 94 48. mechanical robustness : -Vibrations contactor open: 2 Gn, 5...300 Hz -Vibrations contactor closed: 4 Gn, 5...300 Hz -Shocks contactor closed: 15 Gn for 11 ms -Shocks contactor open: 10 Gn for 11 ms 49. height : 122 mm 50. width : 70 mm 51. depth : 120 mm 52. net weight : 1.09 kg
Specifications for Schneider TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 60 A - 48 V AC 50/60 Hz coil
General Information | |
---|---|
# of Pole | 4 |
Arus Pengenal (A) | 60A |
Uncategorized | |
Coil AC | 48V (E7) |
Filter By
[Deskripsi] 1. product name : TeSys D 2. product or component type : Contactor 3. device short name : LC1D 4. contactor application : Resistive load 5. utilisation category : AC-1 6. poles description : 4P 7. power pole contact composition : 4 NO 8. [Ue] rated operational voltage : -Power circuit: <= 690 V AC 25...400 Hz -Power circuit: <= 300 V DC 9. [Ie] rated operational current : 60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit 10. control circuit type : AC at 50/60 Hz 11. [Uc] control circuit voltage : 48 V AC 50/60 Hz 12. auxiliary contact composition : 1 NO + 1 NC 13. [Uimp] rated impulse withstand voltage : 6 kV conforming to IEC 60947 14. overvoltage category : III 15. [Ith] conventional free air thermal current : -10 A (at 60 °C) for signalling circuit -60 A (at 60 °C) for power circuit 16. Irms rated making capacity : -140 A AC for signalling circuit conforming to IEC 60947-5-1 -250 A DC for signalling circuit conforming to IEC 60947-5-1 -800 A at 440 V for power circuit conforming to IEC 60947 17. rated breaking capacity : 800 A at 440 V for power circuit conforming to IEC 60947 18. [Icw] rated short-time withstand current : -320 A 40 °C - 10 s for power circuit -720 A 40 °C - 1 s for power circuit -72 A 40 °C - 10 min for power circuit -165 A 40 °C - 1 min for power circuit -100 A - 1 s for signalling circuit -120 A - 500 ms for signalling circuit -140 A - 100 ms for signalling circuit 19. associated fuse rating : -10 A gG for signalling circuit conforming to IEC 60947-5-1 -80 A gG at <= 690 V coordination type 1 for power circuit -80 A gG at <= 690 V coordination type 2 for power circuit 20. average impedance : 1.6 mOhm - Ith 60 A 50 Hz for power circuit 21. [Ui] rated insulation voltage : -Power circuit: 600 V CSA certified -Power circuit: 600 V UL certified -Signalling circuit: 690 V conforming to IEC 60947-1 -Signalling circuit: 600 V CSA certified -Signalling circuit: 600 V UL certified -Power circuit: 690 V conforming to IEC 60947-4-1 22. electrical durability : 1.4 Mcycles 60 A AC-1 at Ue <= 440 V 23. power dissipation per pole : 5.8 W AC-1 24. safety cover : With 25. mounting support : -Rail -Plate 26. standards : -CSA C22.2 No 14 -EN 60947-4-1 -EN 60947-5-1 -IEC 60947-4-1 -IEC 60947-5-1 -UL 508 27. product certifications : -GOST -BV -UL -CCC -GL -CSA -RINA -LROS (Lloyds register of shipping) -DNV 28. coil technology : Without built-in suppressor module 29. control circuit voltage limits : -Drop-out: 0.3...0.6 Uc AC 50/60 Hz (at 60 °C) -Operational: 0.8...1.1 Uc AC 50 Hz (at 60 °C) -Operational: 0.85...1.1 Uc AC 60 Hz (at 60 °C) 30. inrush power in VA : -140 VA 60 Hz cos phi 0.75 (at 20 °C) -160 VA 50 Hz cos phi 0.75 (at 20 °C) 31. hold-in power consumption in VA : -13 VA 60 Hz cos phi 0.3 (at 20 °C) -15 VA 50 Hz cos phi 0.3 (at 20 °C) 32. heat dissipation : 4…5 W at 50/60 Hz 33. auxiliary contacts type : -type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 -type mirror contact 1 NC conforming to IEC 60947-4-1 34. signalling circuit frequency : 25...400 Hz 35. minimum switching current : 5 mA for signalling circuit 36. minimum switching voltage : 17 V for signalling circuit 37. non-overlap time : -1.5 ms on de-energisation between NC and NO contact -1.5 ms on energisation between NC and NO contact 38. insulation resistance : > 10 MOhm for signalling circuit 39. IP degree of protection : IP20 front face conforming to IEC 60529 40. protective treatment : TH conforming to IEC 60068-2-30 41. pollution degree : 3 42. ambient air temperature for operation : -5…60 °C 43. ambient air temperature for storage : -60…80 °C 44. permissible ambient air temperature around the device : -40…70 °C at Uc 45. operating altitude : 3000 m without 46. fire resistance : 850 °C conforming to IEC 60695-2-1 47. flame retardance : V1 conforming to UL 94 48. mechanical robustness : -Vibrations contactor open: 2 Gn, 5...300 Hz -Vibrations contactor closed: 4 Gn, 5...300 Hz -Shocks contactor closed: 15 Gn for 11 ms -Shocks contactor open: 10 Gn for 11 ms 49. height : 122 mm 50. width : 70 mm 51. depth : 120 mm 52. net weight : 1.09 kg