Schneider TeSys F contactor - 4P(4 NO) - AC-1 - <= 440 V 400 A - without coil
# of Pole : 4
Rp 18,391,809.00
55.00 %
Rp 40,870,688.00
Rp 40,870,688.00
Option not available
[Deskripsi] 1. product name : TeSys F 2. product or component type : Contactor 3. device short name : LC1F 4. contactor application : Resistive load 5. utilisation category : AC-1 6. poles description : 4P 7. power pole contact composition : 4 NO 8. [Ue] rated operational voltage : -<= 1000 V AC 50/60 Hz -<= 460 V DC 9. [Ie] rated operational current : 400 A (at <40 °C) at <= 440 V AC-1 10. [Uimp] rated impulse withstand voltage : 8 kV 11. overvoltage category : III 12. [Ith] conventional free air thermal current : 400 A (at 40 °C) 13. Irms rated making capacity : 3300 A conforming to IEC 60947-4-1 14. rated breaking capacity : 2640 A conforming to IEC 60947-4-1 15. [Icw] rated short-time withstand current : -2650 A 40 °C - 10 s -1800 A 40 °C - 30 s -1300 A 40 °C - 1 min -900 A 40 °C - 3 min -750 A 40 °C - 10 min 16. associated fuse rating : -400 A aM at <= 440 V -500 A gG at <= 440 V 17. average impedance : 0.28 mOhm - Ith 400 A 50 Hz 18. [Ui] rated insulation voltage : -1000 V conforming to IEC 60947-4-1 -1500 V conforming to VDE 0110 group C 19. power dissipation per pole : 44 W AC-1 20. mounting support : Plate 21. standards : -EN 60947-1 -JIS C8201-4-1 -IEC 60947-4-1 -EN 60947-4-1 -IEC 60947-1 22. product certifications : -RINA -ABS -CSA -DNV -RMRoS -BV -LROS (Lloyds register of shipping) -UL -CB 23. connections - terminals : -Power circuit: lugs-ring terminals 1 cable(s) 95 mm² -Power circuit: connector 1 cable(s) 95 mm² -Power circuit: bar 2 cable(s) - busbar cross section: 20 x 3 mm -Power circuit: bolted connection 24. tightening torque : Power circuit: 10 N.m 25. IP degree of protection : -IP2x front face with shrouds conforming to IEC 60529 -IP2x front face with shrouds conforming to VDE 0106 26. protective treatment : TH 27. ambient air temperature for operation : -5…55 °C 28. ambient air temperature for storage : -60…80 °C 29. permissible ambient air temperature around the device : -40…70 °C 30. operating altitude : 3000 m without 31. mechanical robustness : -Vibrations contactor open: 2 Gn, 5...300 Hz -Vibrations contactor closed: 6 Gn, 5...300 Hz -Shocks contactor open: 9 Gn for 1/2 sine wave (11 ms) -Shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms) 32. height : 206 mm 33. width : 261 mm 34. depth : 219 mm 35. net weight : 9.5 kg
range | TeSys | |
---|---|---|
product name | TeSys F | |
product or component type | Contactor | |
device short name | LC1F | |
contactor application | Resistive load | |
utilisation category | AC-1 | |
poles description | 4P | |
power pole contact composition | 4 NO | |
[Ue] rated operational voltage | <= 1000 V AC 50/60 Hz <= 460 V DC | |
[Ie] rated operational current | 400 A (at <40 °C) at <= 440 V AC AC-1 |
[Uc] control circuit voltage | 24...1000 V AC 40...400 Hz with LX1/LX9 coil 24...460 V DC with LX4 coil 100...250 V AC 50/60 Hz with LXE coil 100...380 V DC with LXE coil | |
---|---|---|
[Uimp] rated impulse withstand voltage | 8 kV | |
overvoltage category | III | |
[Ith] conventional free air thermal current | 400 A (at 40 °C) | |
Irms rated making capacity | 3300 A AC conforming to IEC 60947-4-1 | |
rated breaking capacity | 2640 A conforming to IEC 60947-4-1 | |
[Icw] rated short-time withstand current | 2650 A 40 °C - 10 s 1800 A 40 °C - 30 s 1300 A 40 °C - 1 min 900 A 40 °C - 3 min 750 A 40 °C - 10 min | |
associated fuse rating | 400 A aM at <= 440 V 500 A gG at <= 440 V | |
average impedance | 0.28 mOhm - Ith 400 A 50 Hz | |
[Ui] rated insulation voltage | 1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C | |
power dissipation per pole | 44 W AC-1 | |
control circuit voltage limits | Operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coil Drop-out: 0.35...0.55 Uc AC 40...400 Hz with LX1/LX9 coil Operational: 0.85...1.1 Uc DC with LX4 coil Drop-out: 0.15...0.2 Uc DC with LX4 coil Operational: 85...275 V AC 50/60 Hz with LXE coil Drop-out: 0...60 V AC 50/60 Hz with LXE coil Operational: 85...418 V DC with LXE coil Drop-out: 0...45 V DC with LXE coil | |
heat dissipation | 8 W 2.2…5.5 W | |
operating time | 40...65 ms closing for with LX1/LX9 coil 100...170 ms opening for with LX1/LX9 coil 40...50 ms closing for with LX4 coil 40...65 ms opening for with LX4 coil 40...80 ms closing for with LXE coil 6...54 ms opening for with LXE coil | |
mounting support | Plate | |
standards | IEC 60947-4-1 JIS C8201-4-1 EN 60947-1 IEC 60947-1 EN 60947-4-1 | |
product certifications | ABS CSA UL RMRoS DNV CB BV LROS (Lloyds register of shipping) RINA UKCA | |
connections - terminals | Power circuit: lugs-ring terminals 1 cable(s) 240 mm² Power circuit: bar 2 cable(s) - busbar cross section: 30 x 5 mm Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²solid without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm² Control circuit: screw clamp terminals 2 cable(s) 1…4 mm² Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²flexible without cable end Control circuit: screw clamp terminals 1.0 cable(s) 0.25…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²solid without cable end | |
tightening torque | Power circuit: 35 N.m Control circuit: 1.2 N.m Control circuit: 0.6 N.m | |
mechanical durability | 10 Mcycles | |
inrush power in VA | 600…700 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil 655…803 VA (at 20 °C)with LX4 coil 300…350 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil 300…310 VA (at 20 °C)with LXE coil | |
hold-in power consumption in VA | 8…10 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil 3.68…4.53 VA (at 20 °C)with LX4 coil 4.5…7.0 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil 2.5…4.0 VA (at 20 °C)with LXE coil | |
maximum operating rate | 2400 cyc/h 55 °C | |
compatibility code | LC1F |
IP degree of protection | IP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106 | |
---|---|---|
protective treatment | TH | |
ambient air temperature for operation | -5…55 °C | |
ambient air temperature for storage | -60…80 °C | |
permissible ambient air temperature around the device | -40…70 °C | |
operating altitude | 3000 m without derating | |
mechanical robustness | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 5 Gn, 5...300 Hz Shocks contactor open: 6 Gn for 1/2 sine wave (11 ms) Shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms) | |
height | 206 mm | |
width | 261 mm | |
depth | 219 mm | |
net weight | 9.5 kg |
Unit Type of Package 1 | PCE | |
---|---|---|
Number of Units in Package 1 | 1 | |
Package 1 Weight | 10.192 kg | |
Package 1 Height | 24 cm | |
Package 1 width | 25 cm | |
Package 1 Length | 31.5 cm | |
Unit Type of Package 2 | P06 | |
Number of Units in Package 2 | 10 | |
Package 2 Weight | 110.42 kg | |
Package 2 Height | 80 cm | |
Package 2 width | 80 cm | |
Package 2 Length | 60 cm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
EU RoHS Directive | Compliant EU RoHS Declaration | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | China RoHS declaration Product out of China RoHS scope. Substance declaration for your information | |
Environmental Disclosure | ||
Circularity Profile | ||
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | |
California proposition 65 | WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Warranty | 12 months |
---|
Specifications for Schneider TeSys F contactor - 4P(4 NO) - AC-1 - <= 440 V 400 A - without coil
# of Pole | 4 |
Filter By
[Deskripsi] 1. product name : TeSys F 2. product or component type : Contactor 3. device short name : LC1F 4. contactor application : Resistive load 5. utilisation category : AC-1 6. poles description : 4P 7. power pole contact composition : 4 NO 8. [Ue] rated operational voltage : -<= 1000 V AC 50/60 Hz -<= 460 V DC 9. [Ie] rated operational current : 400 A (at <40 °C) at <= 440 V AC-1 10. [Uimp] rated impulse withstand voltage : 8 kV 11. overvoltage category : III 12. [Ith] conventional free air thermal current : 400 A (at 40 °C) 13. Irms rated making capacity : 3300 A conforming to IEC 60947-4-1 14. rated breaking capacity : 2640 A conforming to IEC 60947-4-1 15. [Icw] rated short-time withstand current : -2650 A 40 °C - 10 s -1800 A 40 °C - 30 s -1300 A 40 °C - 1 min -900 A 40 °C - 3 min -750 A 40 °C - 10 min 16. associated fuse rating : -400 A aM at <= 440 V -500 A gG at <= 440 V 17. average impedance : 0.28 mOhm - Ith 400 A 50 Hz 18. [Ui] rated insulation voltage : -1000 V conforming to IEC 60947-4-1 -1500 V conforming to VDE 0110 group C 19. power dissipation per pole : 44 W AC-1 20. mounting support : Plate 21. standards : -EN 60947-1 -JIS C8201-4-1 -IEC 60947-4-1 -EN 60947-4-1 -IEC 60947-1 22. product certifications : -RINA -ABS -CSA -DNV -RMRoS -BV -LROS (Lloyds register of shipping) -UL -CB 23. connections - terminals : -Power circuit: lugs-ring terminals 1 cable(s) 95 mm² -Power circuit: connector 1 cable(s) 95 mm² -Power circuit: bar 2 cable(s) - busbar cross section: 20 x 3 mm -Power circuit: bolted connection 24. tightening torque : Power circuit: 10 N.m 25. IP degree of protection : -IP2x front face with shrouds conforming to IEC 60529 -IP2x front face with shrouds conforming to VDE 0106 26. protective treatment : TH 27. ambient air temperature for operation : -5…55 °C 28. ambient air temperature for storage : -60…80 °C 29. permissible ambient air temperature around the device : -40…70 °C 30. operating altitude : 3000 m without 31. mechanical robustness : -Vibrations contactor open: 2 Gn, 5...300 Hz -Vibrations contactor closed: 6 Gn, 5...300 Hz -Shocks contactor open: 9 Gn for 1/2 sine wave (11 ms) -Shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms) 32. height : 206 mm 33. width : 261 mm 34. depth : 219 mm 35. net weight : 9.5 kg
range | TeSys | |
---|---|---|
product name | TeSys F | |
product or component type | Contactor | |
device short name | LC1F | |
contactor application | Resistive load | |
utilisation category | AC-1 | |
poles description | 4P | |
power pole contact composition | 4 NO | |
[Ue] rated operational voltage | <= 1000 V AC 50/60 Hz <= 460 V DC | |
[Ie] rated operational current | 400 A (at <40 °C) at <= 440 V AC AC-1 |
[Uc] control circuit voltage | 24...1000 V AC 40...400 Hz with LX1/LX9 coil 24...460 V DC with LX4 coil 100...250 V AC 50/60 Hz with LXE coil 100...380 V DC with LXE coil | |
---|---|---|
[Uimp] rated impulse withstand voltage | 8 kV | |
overvoltage category | III | |
[Ith] conventional free air thermal current | 400 A (at 40 °C) | |
Irms rated making capacity | 3300 A AC conforming to IEC 60947-4-1 | |
rated breaking capacity | 2640 A conforming to IEC 60947-4-1 | |
[Icw] rated short-time withstand current | 2650 A 40 °C - 10 s 1800 A 40 °C - 30 s 1300 A 40 °C - 1 min 900 A 40 °C - 3 min 750 A 40 °C - 10 min | |
associated fuse rating | 400 A aM at <= 440 V 500 A gG at <= 440 V | |
average impedance | 0.28 mOhm - Ith 400 A 50 Hz | |
[Ui] rated insulation voltage | 1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C | |
power dissipation per pole | 44 W AC-1 | |
control circuit voltage limits | Operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coil Drop-out: 0.35...0.55 Uc AC 40...400 Hz with LX1/LX9 coil Operational: 0.85...1.1 Uc DC with LX4 coil Drop-out: 0.15...0.2 Uc DC with LX4 coil Operational: 85...275 V AC 50/60 Hz with LXE coil Drop-out: 0...60 V AC 50/60 Hz with LXE coil Operational: 85...418 V DC with LXE coil Drop-out: 0...45 V DC with LXE coil | |
heat dissipation | 8 W 2.2…5.5 W | |
operating time | 40...65 ms closing for with LX1/LX9 coil 100...170 ms opening for with LX1/LX9 coil 40...50 ms closing for with LX4 coil 40...65 ms opening for with LX4 coil 40...80 ms closing for with LXE coil 6...54 ms opening for with LXE coil | |
mounting support | Plate | |
standards | IEC 60947-4-1 JIS C8201-4-1 EN 60947-1 IEC 60947-1 EN 60947-4-1 | |
product certifications | ABS CSA UL RMRoS DNV CB BV LROS (Lloyds register of shipping) RINA UKCA | |
connections - terminals | Power circuit: lugs-ring terminals 1 cable(s) 240 mm² Power circuit: bar 2 cable(s) - busbar cross section: 30 x 5 mm Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²solid without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm² Control circuit: screw clamp terminals 2 cable(s) 1…4 mm² Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²flexible without cable end Control circuit: screw clamp terminals 1.0 cable(s) 0.25…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²solid without cable end | |
tightening torque | Power circuit: 35 N.m Control circuit: 1.2 N.m Control circuit: 0.6 N.m | |
mechanical durability | 10 Mcycles | |
inrush power in VA | 600…700 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil 655…803 VA (at 20 °C)with LX4 coil 300…350 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil 300…310 VA (at 20 °C)with LXE coil | |
hold-in power consumption in VA | 8…10 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil 3.68…4.53 VA (at 20 °C)with LX4 coil 4.5…7.0 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil 2.5…4.0 VA (at 20 °C)with LXE coil | |
maximum operating rate | 2400 cyc/h 55 °C | |
compatibility code | LC1F |
IP degree of protection | IP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106 | |
---|---|---|
protective treatment | TH | |
ambient air temperature for operation | -5…55 °C | |
ambient air temperature for storage | -60…80 °C | |
permissible ambient air temperature around the device | -40…70 °C | |
operating altitude | 3000 m without derating | |
mechanical robustness | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 5 Gn, 5...300 Hz Shocks contactor open: 6 Gn for 1/2 sine wave (11 ms) Shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms) | |
height | 206 mm | |
width | 261 mm | |
depth | 219 mm | |
net weight | 9.5 kg |
Unit Type of Package 1 | PCE | |
---|---|---|
Number of Units in Package 1 | 1 | |
Package 1 Weight | 10.192 kg | |
Package 1 Height | 24 cm | |
Package 1 width | 25 cm | |
Package 1 Length | 31.5 cm | |
Unit Type of Package 2 | P06 | |
Number of Units in Package 2 | 10 | |
Package 2 Weight | 110.42 kg | |
Package 2 Height | 80 cm | |
Package 2 width | 80 cm | |
Package 2 Length | 60 cm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
EU RoHS Directive | Compliant EU RoHS Declaration | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | China RoHS declaration Product out of China RoHS scope. Substance declaration for your information | |
Environmental Disclosure | ||
Circularity Profile | ||
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | |
California proposition 65 | WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Warranty | 12 months |
---|