• Sign up now and get discount up to 47%

Schneider TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 110 V AC coil

# of Pole : 3

Arus Pengenal (A) : 9A

Coil AC : 110V (F7)

Rp 415,017.00 Rp 232,409.00 232409 IDR

Rp 415,017.00

Option not available

  • # of Pole
  • Arus Pengenal (A)
  • Coil AC

This combination does not exist.

Add to Cart

Schneider TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 110 V AC coil
Terjual 0
0 (0 Rating)
Ulasan (0)

Rp 232,409.00
44.00 % Rp 415,017.00 232409 IDR

Rp 415,017.00

Option not available

Atur Jumlah & Catatan
Stock Total: 20

# of Pole : 3

Arus Pengenal (A) : 9A

Coil AC : 110V (F7)

Spesifikasi
Main (see above)
range
TeSys
product or component type
Contactor
product name
TeSys K
device short name
LC1K
device application
Control
contactor application
Resistive load
Motor control
Complementary (see above)
utilisation category
AC-4
AC-1
AC-3
poles description
3P
power pole contact composition
3 NO
[Ie] rated operational current
20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit
9 A at <= 440 V AC AC-3 for power circuit
16 A (at <70 °C) at 690 V AC AC-1 for power circuit
control circuit type
AC at 50/60 Hz
[Uc] control circuit voltage
110 V AC 50/60 Hz
motor power kW
2.2 kW at 220...230 V AC 50/60 Hz AC-3
4 kW at 380...415 V AC 50/60 Hz AC-3
4 kW at 440 V AC 50/60 Hz AC-3
4 kW at 480 V AC 50/60 Hz AC-3
4 kW at 500...600 V AC 50/60 Hz AC-3
4 kW at 660...690 V AC 50/60 Hz AC-3
2.2 kW at 400 V AC 50/60 Hz AC-4
auxiliary contact composition
1 NO
overvoltage category
III
[Ith] conventional free air thermal current
20 A (at 50 °C) for power circuit
10 A (at 50 °C) for signalling circuit
Irms rated making capacity
110 A AC for power circuit conforming to NF C 63-110
110 A AC for power circuit conforming to IEC 60947
110 A AC for signalling circuit conforming to IEC 60947
rated breaking capacity
110 A at 415 V conforming to IEC 60947
110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
110 A at 220...230 V conforming to IEC 60947
110 A at 380...400 V conforming to IEC 60947
70 A at 660...690 V conforming to IEC 60947
associated fuse rating
25 A gG at <= 440 V for power circuit
25 A aM for power circuit
10 A gG for signalling circuit conforming to IEC 60947
10 A gG for signalling circuit conforming to VDE 0660
average impedance
3 mOhm - Ith 20 A 50 Hz for power circuit
insulation resistance
> 10 MOhm for signalling circuit
inrush power in VA
30 VA (at 20 °C)
hold-in power consumption in VA
4.5 VA (at 20 °C)
heat dissipation
1.3 W
control circuit voltage limits
Operational: 0.8...1.15 Uc (at <50 °C)
Drop-out: 0.2...0.75 Uc (at <50 °C)
maximum operating rate
3600 cyc/h
auxiliary contacts type
type instantaneous 1 NO
signalling circuit frequency
<= 400 Hz
minimum switching current
5 mA for signalling circuit
minimum switching voltage
17 V for signalling circuit
operating time
10...20 ms coil de-energisation and NO opening
10...20 ms coil energisation and NO closing
safety reliability level
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
non overlap distance
0.5 mm
mechanical robustness
Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Environment (see above)
product certifications
CSA
UL
protective treatment
TC conforming to IEC 60068
TC conforming to DIN 50016
operating altitude
2000 m without derating
flame retardance
V1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
Packing Units (see above)
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Weight
178 g
Package 1 Height
4.8 cm
Package 1 width
6.2 cm
Package 1 Length
6.6 cm
Unit Type of Package 2
S02
Number of Units in Package 2
50
Package 2 Weight
9.338 kg
Package 2 Height
15 cm
Package 2 width
30 cm
Package 2 Length
40 cm
Unit Type of Package 3
P06
Number of Units in Package 3
800
Package 3 Weight
158.18 kg
Package 3 Height
77 cm
Package 3 width
80 cm
Package 3 Length
60 cm
Offer Sustainability (see above)
Sustainable offer status
Green Premium product
REACh Regulation
REACh free of SVHC
Yes
EU RoHS Directive
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
China RoHS Regulation
China RoHS declaration
 Pro-active China RoHS declaration (out of China RoHS legal scope)
Environmental Disclosure
Circularity Profile
WEEE
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Contractual warranty (see above)
Warranty
12 months

Specifications for Schneider TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 110 V AC coil

General Information
# of Pole 3
Arus Pengenal (A) 9A
Uncategorized
Coil AC 110V (F7)

Filter By

Product Public Price Discount Guaranteed Stock QTY Action
Rp 2,594,924.00 100.00 % 18
Rp 540,369.00 100.00 % Out of Stock
Rp 1,233,757.00 100.00 % Out of Stock
Rp 948,847.00 100.00 % 1
Rp 448,813.00 100.00 % 2
Rp 476,984.00 100.00 % 2
HOT PROMO
Main (see above)
range
TeSys
product or component type
Contactor
product name
TeSys K
device short name
LC1K
device application
Control
contactor application
Resistive load
Motor control
Complementary (see above)
utilisation category
AC-4
AC-1
AC-3
poles description
3P
power pole contact composition
3 NO
[Ie] rated operational current
20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit
9 A at <= 440 V AC AC-3 for power circuit
16 A (at <70 °C) at 690 V AC AC-1 for power circuit
control circuit type
AC at 50/60 Hz
[Uc] control circuit voltage
110 V AC 50/60 Hz
motor power kW
2.2 kW at 220...230 V AC 50/60 Hz AC-3
4 kW at 380...415 V AC 50/60 Hz AC-3
4 kW at 440 V AC 50/60 Hz AC-3
4 kW at 480 V AC 50/60 Hz AC-3
4 kW at 500...600 V AC 50/60 Hz AC-3
4 kW at 660...690 V AC 50/60 Hz AC-3
2.2 kW at 400 V AC 50/60 Hz AC-4
auxiliary contact composition
1 NO
overvoltage category
III
[Ith] conventional free air thermal current
20 A (at 50 °C) for power circuit
10 A (at 50 °C) for signalling circuit
Irms rated making capacity
110 A AC for power circuit conforming to NF C 63-110
110 A AC for power circuit conforming to IEC 60947
110 A AC for signalling circuit conforming to IEC 60947
rated breaking capacity
110 A at 415 V conforming to IEC 60947
110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
110 A at 220...230 V conforming to IEC 60947
110 A at 380...400 V conforming to IEC 60947
70 A at 660...690 V conforming to IEC 60947
associated fuse rating
25 A gG at <= 440 V for power circuit
25 A aM for power circuit
10 A gG for signalling circuit conforming to IEC 60947
10 A gG for signalling circuit conforming to VDE 0660
average impedance
3 mOhm - Ith 20 A 50 Hz for power circuit
insulation resistance
> 10 MOhm for signalling circuit
inrush power in VA
30 VA (at 20 °C)
hold-in power consumption in VA
4.5 VA (at 20 °C)
heat dissipation
1.3 W
control circuit voltage limits
Operational: 0.8...1.15 Uc (at <50 °C)
Drop-out: 0.2...0.75 Uc (at <50 °C)
maximum operating rate
3600 cyc/h
auxiliary contacts type
type instantaneous 1 NO
signalling circuit frequency
<= 400 Hz
minimum switching current
5 mA for signalling circuit
minimum switching voltage
17 V for signalling circuit
operating time
10...20 ms coil de-energisation and NO opening
10...20 ms coil energisation and NO closing
safety reliability level
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
non overlap distance
0.5 mm
mechanical robustness
Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Environment (see above)
product certifications
CSA
UL
protective treatment
TC conforming to IEC 60068
TC conforming to DIN 50016
operating altitude
2000 m without derating
flame retardance
V1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
Packing Units (see above)
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Weight
178 g
Package 1 Height
4.8 cm
Package 1 width
6.2 cm
Package 1 Length
6.6 cm
Unit Type of Package 2
S02
Number of Units in Package 2
50
Package 2 Weight
9.338 kg
Package 2 Height
15 cm
Package 2 width
30 cm
Package 2 Length
40 cm
Unit Type of Package 3
P06
Number of Units in Package 3
800
Package 3 Weight
158.18 kg
Package 3 Height
77 cm
Package 3 width
80 cm
Package 3 Length
60 cm
Offer Sustainability (see above)
Sustainable offer status
Green Premium product
REACh Regulation
REACh free of SVHC
Yes
EU RoHS Directive
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
China RoHS Regulation
China RoHS declaration
 Pro-active China RoHS declaration (out of China RoHS legal scope)
Environmental Disclosure
Circularity Profile
WEEE
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Contractual warranty (see above)
Warranty
12 months