Schneider TeSys K contactor - 3P - AC-3 440 V 9 A - 1 NO aux. - 110 V AC coil
# of Pole : 3
Arus Pengenal (A) : 9A
Coil AC : 110V (F7)
Schneider TeSys K contactor - 3P - AC-3 440 V 9 A - 1 NO aux. - 110 V AC coil
Terjual 0
0 (0 Rating)
Ulasan (0)
Rp 235,757.00
48.00 %
Rp 453,379.00
Rp 453,379.00
Option not available
Spesifikasi
| range | TeSys | |
|---|---|---|
| product or component type | Contactor | |
| product name | TeSys K | |
| device short name | LC1K | |
| device application | Control | |
| contactor application | Resistive load Motor control |
| utilisation category | AC-4 AC-1 AC-3 | |
|---|---|---|
| poles description | 3P | |
| power pole contact composition | 3 NO | |
| [Ie] rated operational current | 20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit 9 A at <= 440 V AC AC-3 for power circuit 16 A (at <70 °C) at 690 V AC AC-1 for power circuit | |
| control circuit type | AC at 50/60 Hz | |
| [Uc] control circuit voltage | 110 V AC 50/60 Hz | |
| motor power kW | 2.2 kW at 220...230 V AC 50/60 Hz AC-3 4 kW at 380...415 V AC 50/60 Hz AC-3 4 kW at 440 V AC 50/60 Hz AC-3 4 kW at 480 V AC 50/60 Hz AC-3 4 kW at 500...600 V AC 50/60 Hz AC-3 4 kW at 660...690 V AC 50/60 Hz AC-3 2.2 kW at 400 V AC 50/60 Hz AC-4 | |
| auxiliary contact composition | 1 NO | |
| overvoltage category | III | |
| [Ith] conventional free air thermal current | 20 A (at 50 °C) for power circuit 10 A (at 50 °C) for signalling circuit | |
| Irms rated making capacity | 110 A AC for power circuit conforming to NF C 63-110 110 A AC for power circuit conforming to IEC 60947 110 A AC for signalling circuit conforming to IEC 60947 | |
| rated breaking capacity | 110 A at 415 V conforming to IEC 60947 110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 110 A at 220...230 V conforming to IEC 60947 110 A at 380...400 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947 | |
| associated fuse rating | 25 A gG at <= 440 V for power circuit 25 A aM for power circuit 10 A gG for signalling circuit conforming to IEC 60947 10 A gG for signalling circuit conforming to VDE 0660 | |
| average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit | |
| insulation resistance | > 10 MOhm for signalling circuit | |
| inrush power in VA | 30 VA (at 20 °C) | |
| hold-in power consumption in VA | 4.5 VA (at 20 °C) | |
| heat dissipation | 1.3 W | |
| control circuit voltage limits | Operational: 0.8...1.15 Uc (at <50 °C) Drop-out: 0.2...0.75 Uc (at <50 °C) | |
| maximum operating rate | 3600 cyc/h | |
| auxiliary contacts type | type instantaneous 1 NO | |
| signalling circuit frequency | <= 400 Hz | |
| minimum switching current | 5 mA for signalling circuit | |
| minimum switching voltage | 17 V for signalling circuit | |
| operating time | 10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing | |
| safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | |
| non overlap distance | 0.5 mm | |
| mechanical robustness | Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 |
| product certifications | CSA UL | |
|---|---|---|
| protective treatment | TC conforming to IEC 60068 TC conforming to DIN 50016 | |
| operating altitude | 2000 m without derating | |
| flame retardance | V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102 |
| Unit Type of Package 1 | PCE | |
|---|---|---|
| Number of Units in Package 1 | 1 | |
| Package 1 Weight | 178 g | |
| Package 1 Height | 4.8 cm | |
| Package 1 width | 6.2 cm | |
| Package 1 Length | 6.6 cm | |
| Unit Type of Package 2 | S02 | |
| Number of Units in Package 2 | 50 | |
| Package 2 Weight | 9.338 kg | |
| Package 2 Height | 15 cm | |
| Package 2 width | 30 cm | |
| Package 2 Length | 40 cm | |
| Unit Type of Package 3 | P06 | |
| Number of Units in Package 3 | 800 | |
| Package 3 Weight | 158.18 kg | |
| Package 3 Height | 77 cm | |
| Package 3 width | 80 cm | |
| Package 3 Length | 60 cm |
| Sustainable offer status | Green Premium product | |
|---|---|---|
| REACh Regulation | ||
| REACh free of SVHC | Yes | |
| EU RoHS Directive | Compliant EU RoHS Declaration | |
| Toxic heavy metal free | Yes | |
| Mercury free | Yes | |
| RoHS exemption information | ||
| China RoHS Regulation | China RoHS declaration Pro-active China RoHS declaration (out of China RoHS legal scope) | |
| Environmental Disclosure | ||
| Circularity Profile | ||
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Warranty | 12 months |
|---|
Specifications for Schneider TeSys K contactor - 3P - AC-3 440 V 9 A - 1 NO aux. - 110 V AC coil
| General Information | |
|---|---|
| # of Pole | 3 |
| Arus Pengenal (A) | 9A |
| Uncategorized | |
| Coil AC | 110V (F7) |
| range | TeSys | |
|---|---|---|
| product or component type | Contactor | |
| product name | TeSys K | |
| device short name | LC1K | |
| device application | Control | |
| contactor application | Resistive load Motor control |
| utilisation category | AC-4 AC-1 AC-3 | |
|---|---|---|
| poles description | 3P | |
| power pole contact composition | 3 NO | |
| [Ie] rated operational current | 20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit 9 A at <= 440 V AC AC-3 for power circuit 16 A (at <70 °C) at 690 V AC AC-1 for power circuit | |
| control circuit type | AC at 50/60 Hz | |
| [Uc] control circuit voltage | 110 V AC 50/60 Hz | |
| motor power kW | 2.2 kW at 220...230 V AC 50/60 Hz AC-3 4 kW at 380...415 V AC 50/60 Hz AC-3 4 kW at 440 V AC 50/60 Hz AC-3 4 kW at 480 V AC 50/60 Hz AC-3 4 kW at 500...600 V AC 50/60 Hz AC-3 4 kW at 660...690 V AC 50/60 Hz AC-3 2.2 kW at 400 V AC 50/60 Hz AC-4 | |
| auxiliary contact composition | 1 NO | |
| overvoltage category | III | |
| [Ith] conventional free air thermal current | 20 A (at 50 °C) for power circuit 10 A (at 50 °C) for signalling circuit | |
| Irms rated making capacity | 110 A AC for power circuit conforming to NF C 63-110 110 A AC for power circuit conforming to IEC 60947 110 A AC for signalling circuit conforming to IEC 60947 | |
| rated breaking capacity | 110 A at 415 V conforming to IEC 60947 110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 110 A at 220...230 V conforming to IEC 60947 110 A at 380...400 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947 | |
| associated fuse rating | 25 A gG at <= 440 V for power circuit 25 A aM for power circuit 10 A gG for signalling circuit conforming to IEC 60947 10 A gG for signalling circuit conforming to VDE 0660 | |
| average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit | |
| insulation resistance | > 10 MOhm for signalling circuit | |
| inrush power in VA | 30 VA (at 20 °C) | |
| hold-in power consumption in VA | 4.5 VA (at 20 °C) | |
| heat dissipation | 1.3 W | |
| control circuit voltage limits | Operational: 0.8...1.15 Uc (at <50 °C) Drop-out: 0.2...0.75 Uc (at <50 °C) | |
| maximum operating rate | 3600 cyc/h | |
| auxiliary contacts type | type instantaneous 1 NO | |
| signalling circuit frequency | <= 400 Hz | |
| minimum switching current | 5 mA for signalling circuit | |
| minimum switching voltage | 17 V for signalling circuit | |
| operating time | 10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing | |
| safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | |
| non overlap distance | 0.5 mm | |
| mechanical robustness | Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 |
| product certifications | CSA UL | |
|---|---|---|
| protective treatment | TC conforming to IEC 60068 TC conforming to DIN 50016 | |
| operating altitude | 2000 m without derating | |
| flame retardance | V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102 |
| Unit Type of Package 1 | PCE | |
|---|---|---|
| Number of Units in Package 1 | 1 | |
| Package 1 Weight | 178 g | |
| Package 1 Height | 4.8 cm | |
| Package 1 width | 6.2 cm | |
| Package 1 Length | 6.6 cm | |
| Unit Type of Package 2 | S02 | |
| Number of Units in Package 2 | 50 | |
| Package 2 Weight | 9.338 kg | |
| Package 2 Height | 15 cm | |
| Package 2 width | 30 cm | |
| Package 2 Length | 40 cm | |
| Unit Type of Package 3 | P06 | |
| Number of Units in Package 3 | 800 | |
| Package 3 Weight | 158.18 kg | |
| Package 3 Height | 77 cm | |
| Package 3 width | 80 cm | |
| Package 3 Length | 60 cm |
| Sustainable offer status | Green Premium product | |
|---|---|---|
| REACh Regulation | ||
| REACh free of SVHC | Yes | |
| EU RoHS Directive | Compliant EU RoHS Declaration | |
| Toxic heavy metal free | Yes | |
| Mercury free | Yes | |
| RoHS exemption information | ||
| China RoHS Regulation | China RoHS declaration Pro-active China RoHS declaration (out of China RoHS legal scope) | |
| Environmental Disclosure | ||
| Circularity Profile | ||
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Warranty | 12 months |
|---|
Recently Viewed Products
Schneider TeSys K contactor - 3P - AC-3 440 V 9 A - 1 NO aux. - 110 V AC coil
Rp 453,379.00
Rp 261,690.00
HOT PROMO