Schneider TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 24 V DC coil

# of Pole : 3

Arus Pengenal (A) : 9A

Coil DC : 24V (BD)

Rp 546,497.00 Rp 306,038.00 306038 IDR

Rp 546,497.00

Option not available

  • # of Pole
  • Arus Pengenal (A)
  • Coil DC

This combination does not exist.

Add to Cart

Schneider TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 24 V DC coil
Terjual 0
0 (0 Rating)
Ulasan (0)

Rp 306,038.00
44.00 % Rp 546,497.00 306038 IDR

Rp 546,497.00

Option not available

Atur Jumlah & Catatan
Stock Total: 48

# of Pole : 3

Arus Pengenal (A) : 9A

Coil DC : 24V (BD)

Spesifikasi

[Deskripsi] 1. product name : TeSys K 2. device short name : LP1K 3. device application : Control 4. contactor application : -Resistive load -Motor control 5. utilisation category : -AC-1 -AC-4 -AC-3 6. poles description : 3P 7. power pole contact composition : 3 NO 8. [Ue] rated operational voltage : -Power circuit: 690 V AC 50/60 Hz -Signalling circuit: <= 690 V AC 50/60 Hz 9. [Ie] rated operational current : -20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit -9 A at <= 440 V AC AC-3 for power circuit -16 A (at <70 °C) at 690 V AC AC-1 for power circuit 10. control circuit type : DC standard 11. [Uc] control circuit voltage : 24 V DC 12. motor power kW : -2.2 kW at 220...230 V AC 50/60 Hz AC-3 -4 kW at 380...415 V AC 50/60 Hz AC-3 -4 kW at 440 V AC 50/60 Hz AC-3 -4 kW at 480 V AC 50/60 Hz AC-3 -4 kW at 500...600 V AC 50/60 Hz AC-3 -4 kW at 660...690 V AC 50/60 Hz AC-3 -2.2 kW at 400 V AC 50/60 Hz AC-4 13. auxiliary contact composition : 1 NO 14. [Uimp] rated impulse withstand voltage : 8 kV 15. overvoltage category : III 16. [Ith] conventional free air thermal current : -20 A (at 50 °C) for power circuit -10 A (at 50 °C) for signalling circuit 17. Irms rated making capacity : -110 A AC for power circuit conforming to NF C 63-110 -110 A AC for power circuit conforming to IEC 60947 -110 A AC for signalling circuit conforming to IEC 60947 18. rated breaking capacity : -110 A at 415 V conforming to IEC 60947 -110 A at 440 V conforming to IEC 60947 -80 A at 500 V conforming to IEC 60947 -110 A at 220...230 V conforming to IEC 60947 -110 A at 380...400 V conforming to IEC 60947 -70 A at 660...690 V conforming to IEC 60947 19. auxiliary contacts type : type instantaneous 1 NO 20. minimum switching current : 5 mA for signalling circuit 21. minimum switching voltage : 17 V for signalling circuit 22. mounting support : -Rail -Plate 23. tightening torque : -1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2 -1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm 24. operating time : -30...40 ms coil energisation and NO closing -10 ms coil de-energisation and NO opening 25. safety reliability level : -B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 -B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 26. non overlap distance : 0.5 mm 27. mechanical durability : 10 Mcycles 28. electrical durability : 1.3 Mcycles 6 A AC-3 at Ue <= 440 V 29. height : 58 mm 30. width : 45 mm 31. depth : 57 mm 30. net weight : 0.225 kg


Main (see above)
range of product
TeSys K
range
TeSys
product or component type
Contactor
device short name
LP1K
contactor application
Motor control
Resistive load
utilisation category
AC-3
AC-1
AC-4
poles description
3P
pole contact composition
3 NO
[Ie] rated operational current
20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit
9 A at <= 440 V AC AC-3 for power circuit
16 A (at <70 °C) at 690 V AC AC-1 for power circuit
auxiliary contact composition
1 NO
Complementary (see above)
auxiliary contacts type
type instantaneous 1 NO
control circuit voltage limits
Operational: 0.8...1.15 Uc (at <50 °C)
Drop-out: 0.1...0.75 Uc (at <50 °C)
[Ui] rated insulation voltage
Power circuit: 600 V conforming to UL 508
Power circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-5-1
Signalling circuit: 600 V conforming to UL 508
Power circuit: 600 V conforming to CSA C22.2 No 14
Signalling circuit: 600 V conforming to CSA C22.2 No 14
[Uimp] rated impulse withstand voltage
8 kV
overvoltage category
III
mounting support
Rail
Plate
flame retardance
V1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
tightening torque
1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2
1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
[Ue] rated operational voltage
Power circuit: 690 V AC 50/60 Hz
Signalling circuit: <= 690 V AC 50/60 Hz
[Ith] conventional free air thermal current
20 A (at 50 °C) for power circuit
10 A (at 50 °C) for signalling circuit
Irms rated making capacity
110 A AC for power circuit conforming to NF C 63-110
110 A AC for power circuit conforming to IEC 60947
110 A AC for signalling circuit conforming to IEC 60947
rated breaking capacity
110 A at 415 V conforming to IEC 60947
110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
110 A at 220...230 V conforming to IEC 60947
110 A at 380...400 V conforming to IEC 60947
70 A at 660...690 V conforming to IEC 60947
associated fuse rating
25 A gG at <= 440 V for power circuit
25 A aM for power circuit
10 A gG for signalling circuit conforming to IEC 60947
10 A gG for signalling circuit conforming to VDE 0660
average impedance
3 mOhm - Ith 20 A 50 Hz for power circuit
inrush power in W
3 W (at 20 °C)
hold-in power consumption in W
3 W at 20 °C
operating time
30...40 ms coil energisation and NO closing
10 ms coil de-energisation and NO opening
safety reliability level
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
mechanical durability
10 Mcycles
maximum operating rate
3600 cyc/h
minimum switching current
5 mA for signalling circuit
minimum switching voltage
17 V for signalling circuit
insulation resistance
> 10 MOhm for signalling circuit
height
58 mm
width
45 mm
depth
57 mm
net weight
0.225 kg
Environment (see above)
product certifications
UL
CSA
ambient air temperature for operation
-25…50 °C
ambient air temperature for storage
-50…80 °C
operating altitude
2000 m without derating
Packing Units (see above)
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Weight
222 g
Package 1 Height
6.5 cm
Package 1 width
4.8 cm
Package 1 Length
6.2 cm
Unit Type of Package 2
S02
Number of Units in Package 2
40
Package 2 Weight
9.335 kg
Package 2 Height
15 cm
Package 2 width
30 cm
Package 2 Length
40 cm
Unit Type of Package 3
P06
Number of Units in Package 3
640
Package 3 Weight
156.58 kg
Package 3 Height
80 cm
Package 3 width
80 cm
Package 3 Length
60 cm
Offer Sustainability (see above)
Sustainable offer status
Green Premium product
REACh Regulation
REACh free of SVHC
Yes
EU RoHS Directive
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
China RoHS Regulation
China RoHS declaration
 Pro-active China RoHS declaration (out of China RoHS legal scope)
Environmental Disclosure
Circularity Profile
WEEE
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
California proposition 65
WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Contractual warranty (see above)
Warranty
12 months

Specifications for Schneider TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 24 V DC coil

General Information
# of Pole 3
Arus Pengenal (A) 9A
Uncategorized
Coil DC 24V (BD)

Filter By

Product Public Price Discount Guaranteed Stock QTY Action
Rp 435,368.00 100.00 % 32
  • # of Pole
  • Arus Pengenal (A)
  • Coil AC
HOT PROMO

[Deskripsi] 1. product name : TeSys K 2. device short name : LP1K 3. device application : Control 4. contactor application : -Resistive load -Motor control 5. utilisation category : -AC-1 -AC-4 -AC-3 6. poles description : 3P 7. power pole contact composition : 3 NO 8. [Ue] rated operational voltage : -Power circuit: 690 V AC 50/60 Hz -Signalling circuit: <= 690 V AC 50/60 Hz 9. [Ie] rated operational current : -20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit -9 A at <= 440 V AC AC-3 for power circuit -16 A (at <70 °C) at 690 V AC AC-1 for power circuit 10. control circuit type : DC standard 11. [Uc] control circuit voltage : 24 V DC 12. motor power kW : -2.2 kW at 220...230 V AC 50/60 Hz AC-3 -4 kW at 380...415 V AC 50/60 Hz AC-3 -4 kW at 440 V AC 50/60 Hz AC-3 -4 kW at 480 V AC 50/60 Hz AC-3 -4 kW at 500...600 V AC 50/60 Hz AC-3 -4 kW at 660...690 V AC 50/60 Hz AC-3 -2.2 kW at 400 V AC 50/60 Hz AC-4 13. auxiliary contact composition : 1 NO 14. [Uimp] rated impulse withstand voltage : 8 kV 15. overvoltage category : III 16. [Ith] conventional free air thermal current : -20 A (at 50 °C) for power circuit -10 A (at 50 °C) for signalling circuit 17. Irms rated making capacity : -110 A AC for power circuit conforming to NF C 63-110 -110 A AC for power circuit conforming to IEC 60947 -110 A AC for signalling circuit conforming to IEC 60947 18. rated breaking capacity : -110 A at 415 V conforming to IEC 60947 -110 A at 440 V conforming to IEC 60947 -80 A at 500 V conforming to IEC 60947 -110 A at 220...230 V conforming to IEC 60947 -110 A at 380...400 V conforming to IEC 60947 -70 A at 660...690 V conforming to IEC 60947 19. auxiliary contacts type : type instantaneous 1 NO 20. minimum switching current : 5 mA for signalling circuit 21. minimum switching voltage : 17 V for signalling circuit 22. mounting support : -Rail -Plate 23. tightening torque : -1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2 -1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm 24. operating time : -30...40 ms coil energisation and NO closing -10 ms coil de-energisation and NO opening 25. safety reliability level : -B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 -B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 26. non overlap distance : 0.5 mm 27. mechanical durability : 10 Mcycles 28. electrical durability : 1.3 Mcycles 6 A AC-3 at Ue <= 440 V 29. height : 58 mm 30. width : 45 mm 31. depth : 57 mm 30. net weight : 0.225 kg


Main (see above)
range of product
TeSys K
range
TeSys
product or component type
Contactor
device short name
LP1K
contactor application
Motor control
Resistive load
utilisation category
AC-3
AC-1
AC-4
poles description
3P
pole contact composition
3 NO
[Ie] rated operational current
20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit
9 A at <= 440 V AC AC-3 for power circuit
16 A (at <70 °C) at 690 V AC AC-1 for power circuit
auxiliary contact composition
1 NO
Complementary (see above)
auxiliary contacts type
type instantaneous 1 NO
control circuit voltage limits
Operational: 0.8...1.15 Uc (at <50 °C)
Drop-out: 0.1...0.75 Uc (at <50 °C)
[Ui] rated insulation voltage
Power circuit: 600 V conforming to UL 508
Power circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-5-1
Signalling circuit: 600 V conforming to UL 508
Power circuit: 600 V conforming to CSA C22.2 No 14
Signalling circuit: 600 V conforming to CSA C22.2 No 14
[Uimp] rated impulse withstand voltage
8 kV
overvoltage category
III
mounting support
Rail
Plate
flame retardance
V1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
tightening torque
1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2
1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
[Ue] rated operational voltage
Power circuit: 690 V AC 50/60 Hz
Signalling circuit: <= 690 V AC 50/60 Hz
[Ith] conventional free air thermal current
20 A (at 50 °C) for power circuit
10 A (at 50 °C) for signalling circuit
Irms rated making capacity
110 A AC for power circuit conforming to NF C 63-110
110 A AC for power circuit conforming to IEC 60947
110 A AC for signalling circuit conforming to IEC 60947
rated breaking capacity
110 A at 415 V conforming to IEC 60947
110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
110 A at 220...230 V conforming to IEC 60947
110 A at 380...400 V conforming to IEC 60947
70 A at 660...690 V conforming to IEC 60947
associated fuse rating
25 A gG at <= 440 V for power circuit
25 A aM for power circuit
10 A gG for signalling circuit conforming to IEC 60947
10 A gG for signalling circuit conforming to VDE 0660
average impedance
3 mOhm - Ith 20 A 50 Hz for power circuit
inrush power in W
3 W (at 20 °C)
hold-in power consumption in W
3 W at 20 °C
operating time
30...40 ms coil energisation and NO closing
10 ms coil de-energisation and NO opening
safety reliability level
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
mechanical durability
10 Mcycles
maximum operating rate
3600 cyc/h
minimum switching current
5 mA for signalling circuit
minimum switching voltage
17 V for signalling circuit
insulation resistance
> 10 MOhm for signalling circuit
height
58 mm
width
45 mm
depth
57 mm
net weight
0.225 kg
Environment (see above)
product certifications
UL
CSA
ambient air temperature for operation
-25…50 °C
ambient air temperature for storage
-50…80 °C
operating altitude
2000 m without derating
Packing Units (see above)
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Weight
222 g
Package 1 Height
6.5 cm
Package 1 width
4.8 cm
Package 1 Length
6.2 cm
Unit Type of Package 2
S02
Number of Units in Package 2
40
Package 2 Weight
9.335 kg
Package 2 Height
15 cm
Package 2 width
30 cm
Package 2 Length
40 cm
Unit Type of Package 3
P06
Number of Units in Package 3
640
Package 3 Weight
156.58 kg
Package 3 Height
80 cm
Package 3 width
80 cm
Package 3 Length
60 cm
Offer Sustainability (see above)
Sustainable offer status
Green Premium product
REACh Regulation
REACh free of SVHC
Yes
EU RoHS Directive
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
China RoHS Regulation
China RoHS declaration
 Pro-active China RoHS declaration (out of China RoHS legal scope)
Environmental Disclosure
Circularity Profile
WEEE
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
California proposition 65
WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Contractual warranty (see above)
Warranty
12 months