Schneider TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 24 V DC coil
# of Pole : 3
Arus Pengenal (A) : 9A
Coil DC : 24V (BD)
Rp 306,038.00
44.00 %
Rp 546,497.00
Rp 546,497.00
Option not available
[Deskripsi] 1. product name : TeSys K 2. device short name : LP1K 3. device application : Control 4. contactor application : -Resistive load -Motor control 5. utilisation category : -AC-1 -AC-4 -AC-3 6. poles description : 3P 7. power pole contact composition : 3 NO 8. [Ue] rated operational voltage : -Power circuit: 690 V AC 50/60 Hz -Signalling circuit: <= 690 V AC 50/60 Hz 9. [Ie] rated operational current : -20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit -9 A at <= 440 V AC AC-3 for power circuit -16 A (at <70 °C) at 690 V AC AC-1 for power circuit 10. control circuit type : DC standard 11. [Uc] control circuit voltage : 24 V DC 12. motor power kW : -2.2 kW at 220...230 V AC 50/60 Hz AC-3 -4 kW at 380...415 V AC 50/60 Hz AC-3 -4 kW at 440 V AC 50/60 Hz AC-3 -4 kW at 480 V AC 50/60 Hz AC-3 -4 kW at 500...600 V AC 50/60 Hz AC-3 -4 kW at 660...690 V AC 50/60 Hz AC-3 -2.2 kW at 400 V AC 50/60 Hz AC-4 13. auxiliary contact composition : 1 NO 14. [Uimp] rated impulse withstand voltage : 8 kV 15. overvoltage category : III 16. [Ith] conventional free air thermal current : -20 A (at 50 °C) for power circuit -10 A (at 50 °C) for signalling circuit 17. Irms rated making capacity : -110 A AC for power circuit conforming to NF C 63-110 -110 A AC for power circuit conforming to IEC 60947 -110 A AC for signalling circuit conforming to IEC 60947 18. rated breaking capacity : -110 A at 415 V conforming to IEC 60947 -110 A at 440 V conforming to IEC 60947 -80 A at 500 V conforming to IEC 60947 -110 A at 220...230 V conforming to IEC 60947 -110 A at 380...400 V conforming to IEC 60947 -70 A at 660...690 V conforming to IEC 60947 19. auxiliary contacts type : type instantaneous 1 NO 20. minimum switching current : 5 mA for signalling circuit 21. minimum switching voltage : 17 V for signalling circuit 22. mounting support : -Rail -Plate 23. tightening torque : -1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2 -1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm 24. operating time : -30...40 ms coil energisation and NO closing -10 ms coil de-energisation and NO opening 25. safety reliability level : -B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 -B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 26. non overlap distance : 0.5 mm 27. mechanical durability : 10 Mcycles 28. electrical durability : 1.3 Mcycles 6 A AC-3 at Ue <= 440 V 29. height : 58 mm 30. width : 45 mm 31. depth : 57 mm 30. net weight : 0.225 kg
range of product | TeSys K | |
---|---|---|
range | TeSys | |
product or component type | Contactor | |
device short name | LP1K | |
contactor application | Motor control Resistive load | |
utilisation category | AC-3 AC-1 AC-4 | |
poles description | 3P | |
pole contact composition | 3 NO | |
[Ie] rated operational current | 20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit 9 A at <= 440 V AC AC-3 for power circuit 16 A (at <70 °C) at 690 V AC AC-1 for power circuit | |
auxiliary contact composition | 1 NO |
auxiliary contacts type | type instantaneous 1 NO | |
---|---|---|
control circuit voltage limits | Operational: 0.8...1.15 Uc (at <50 °C) Drop-out: 0.1...0.75 Uc (at <50 °C) | |
[Ui] rated insulation voltage | Power circuit: 600 V conforming to UL 508 Power circuit: 690 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-5-1 Signalling circuit: 600 V conforming to UL 508 Power circuit: 600 V conforming to CSA C22.2 No 14 Signalling circuit: 600 V conforming to CSA C22.2 No 14 | |
[Uimp] rated impulse withstand voltage | 8 kV | |
overvoltage category | III | |
mounting support | Rail Plate | |
flame retardance | V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102 | |
tightening torque | 1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2 1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm | |
[Ue] rated operational voltage | Power circuit: 690 V AC 50/60 Hz Signalling circuit: <= 690 V AC 50/60 Hz | |
[Ith] conventional free air thermal current | 20 A (at 50 °C) for power circuit 10 A (at 50 °C) for signalling circuit | |
Irms rated making capacity | 110 A AC for power circuit conforming to NF C 63-110 110 A AC for power circuit conforming to IEC 60947 110 A AC for signalling circuit conforming to IEC 60947 | |
rated breaking capacity | 110 A at 415 V conforming to IEC 60947 110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 110 A at 220...230 V conforming to IEC 60947 110 A at 380...400 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947 | |
associated fuse rating | 25 A gG at <= 440 V for power circuit 25 A aM for power circuit 10 A gG for signalling circuit conforming to IEC 60947 10 A gG for signalling circuit conforming to VDE 0660 | |
average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit | |
inrush power in W | 3 W (at 20 °C) | |
hold-in power consumption in W | 3 W at 20 °C | |
operating time | 30...40 ms coil energisation and NO closing 10 ms coil de-energisation and NO opening | |
safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | |
mechanical durability | 10 Mcycles | |
maximum operating rate | 3600 cyc/h | |
minimum switching current | 5 mA for signalling circuit | |
minimum switching voltage | 17 V for signalling circuit | |
insulation resistance | > 10 MOhm for signalling circuit | |
height | 58 mm | |
width | 45 mm | |
depth | 57 mm | |
net weight | 0.225 kg |
product certifications | UL CSA | |
---|---|---|
ambient air temperature for operation | -25…50 °C | |
ambient air temperature for storage | -50…80 °C | |
operating altitude | 2000 m without derating |
Unit Type of Package 1 | PCE | |
---|---|---|
Number of Units in Package 1 | 1 | |
Package 1 Weight | 222 g | |
Package 1 Height | 6.5 cm | |
Package 1 width | 4.8 cm | |
Package 1 Length | 6.2 cm | |
Unit Type of Package 2 | S02 | |
Number of Units in Package 2 | 40 | |
Package 2 Weight | 9.335 kg | |
Package 2 Height | 15 cm | |
Package 2 width | 30 cm | |
Package 2 Length | 40 cm | |
Unit Type of Package 3 | P06 | |
Number of Units in Package 3 | 640 | |
Package 3 Weight | 156.58 kg | |
Package 3 Height | 80 cm | |
Package 3 width | 80 cm | |
Package 3 Length | 60 cm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
REACh free of SVHC | Yes | |
EU RoHS Directive | Compliant EU RoHS Declaration | |
Toxic heavy metal free | Yes | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | China RoHS declaration Pro-active China RoHS declaration (out of China RoHS legal scope) | |
Environmental Disclosure | ||
Circularity Profile | ||
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | |
California proposition 65 | WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov |
Warranty | 12 months |
---|
Specifications for Schneider TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 24 V DC coil
General Information | |
---|---|
# of Pole | 3 |
Arus Pengenal (A) | 9A |
Uncategorized | |
Coil DC | 24V (BD) |
[Deskripsi] 1. product name : TeSys K 2. device short name : LP1K 3. device application : Control 4. contactor application : -Resistive load -Motor control 5. utilisation category : -AC-1 -AC-4 -AC-3 6. poles description : 3P 7. power pole contact composition : 3 NO 8. [Ue] rated operational voltage : -Power circuit: 690 V AC 50/60 Hz -Signalling circuit: <= 690 V AC 50/60 Hz 9. [Ie] rated operational current : -20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit -9 A at <= 440 V AC AC-3 for power circuit -16 A (at <70 °C) at 690 V AC AC-1 for power circuit 10. control circuit type : DC standard 11. [Uc] control circuit voltage : 24 V DC 12. motor power kW : -2.2 kW at 220...230 V AC 50/60 Hz AC-3 -4 kW at 380...415 V AC 50/60 Hz AC-3 -4 kW at 440 V AC 50/60 Hz AC-3 -4 kW at 480 V AC 50/60 Hz AC-3 -4 kW at 500...600 V AC 50/60 Hz AC-3 -4 kW at 660...690 V AC 50/60 Hz AC-3 -2.2 kW at 400 V AC 50/60 Hz AC-4 13. auxiliary contact composition : 1 NO 14. [Uimp] rated impulse withstand voltage : 8 kV 15. overvoltage category : III 16. [Ith] conventional free air thermal current : -20 A (at 50 °C) for power circuit -10 A (at 50 °C) for signalling circuit 17. Irms rated making capacity : -110 A AC for power circuit conforming to NF C 63-110 -110 A AC for power circuit conforming to IEC 60947 -110 A AC for signalling circuit conforming to IEC 60947 18. rated breaking capacity : -110 A at 415 V conforming to IEC 60947 -110 A at 440 V conforming to IEC 60947 -80 A at 500 V conforming to IEC 60947 -110 A at 220...230 V conforming to IEC 60947 -110 A at 380...400 V conforming to IEC 60947 -70 A at 660...690 V conforming to IEC 60947 19. auxiliary contacts type : type instantaneous 1 NO 20. minimum switching current : 5 mA for signalling circuit 21. minimum switching voltage : 17 V for signalling circuit 22. mounting support : -Rail -Plate 23. tightening torque : -1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2 -1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm 24. operating time : -30...40 ms coil energisation and NO closing -10 ms coil de-energisation and NO opening 25. safety reliability level : -B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 -B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 26. non overlap distance : 0.5 mm 27. mechanical durability : 10 Mcycles 28. electrical durability : 1.3 Mcycles 6 A AC-3 at Ue <= 440 V 29. height : 58 mm 30. width : 45 mm 31. depth : 57 mm 30. net weight : 0.225 kg
range of product | TeSys K | |
---|---|---|
range | TeSys | |
product or component type | Contactor | |
device short name | LP1K | |
contactor application | Motor control Resistive load | |
utilisation category | AC-3 AC-1 AC-4 | |
poles description | 3P | |
pole contact composition | 3 NO | |
[Ie] rated operational current | 20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit 9 A at <= 440 V AC AC-3 for power circuit 16 A (at <70 °C) at 690 V AC AC-1 for power circuit | |
auxiliary contact composition | 1 NO |
auxiliary contacts type | type instantaneous 1 NO | |
---|---|---|
control circuit voltage limits | Operational: 0.8...1.15 Uc (at <50 °C) Drop-out: 0.1...0.75 Uc (at <50 °C) | |
[Ui] rated insulation voltage | Power circuit: 600 V conforming to UL 508 Power circuit: 690 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-5-1 Signalling circuit: 600 V conforming to UL 508 Power circuit: 600 V conforming to CSA C22.2 No 14 Signalling circuit: 600 V conforming to CSA C22.2 No 14 | |
[Uimp] rated impulse withstand voltage | 8 kV | |
overvoltage category | III | |
mounting support | Rail Plate | |
flame retardance | V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102 | |
tightening torque | 1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2 1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm | |
[Ue] rated operational voltage | Power circuit: 690 V AC 50/60 Hz Signalling circuit: <= 690 V AC 50/60 Hz | |
[Ith] conventional free air thermal current | 20 A (at 50 °C) for power circuit 10 A (at 50 °C) for signalling circuit | |
Irms rated making capacity | 110 A AC for power circuit conforming to NF C 63-110 110 A AC for power circuit conforming to IEC 60947 110 A AC for signalling circuit conforming to IEC 60947 | |
rated breaking capacity | 110 A at 415 V conforming to IEC 60947 110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 110 A at 220...230 V conforming to IEC 60947 110 A at 380...400 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947 | |
associated fuse rating | 25 A gG at <= 440 V for power circuit 25 A aM for power circuit 10 A gG for signalling circuit conforming to IEC 60947 10 A gG for signalling circuit conforming to VDE 0660 | |
average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit | |
inrush power in W | 3 W (at 20 °C) | |
hold-in power consumption in W | 3 W at 20 °C | |
operating time | 30...40 ms coil energisation and NO closing 10 ms coil de-energisation and NO opening | |
safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | |
mechanical durability | 10 Mcycles | |
maximum operating rate | 3600 cyc/h | |
minimum switching current | 5 mA for signalling circuit | |
minimum switching voltage | 17 V for signalling circuit | |
insulation resistance | > 10 MOhm for signalling circuit | |
height | 58 mm | |
width | 45 mm | |
depth | 57 mm | |
net weight | 0.225 kg |
product certifications | UL CSA | |
---|---|---|
ambient air temperature for operation | -25…50 °C | |
ambient air temperature for storage | -50…80 °C | |
operating altitude | 2000 m without derating |
Unit Type of Package 1 | PCE | |
---|---|---|
Number of Units in Package 1 | 1 | |
Package 1 Weight | 222 g | |
Package 1 Height | 6.5 cm | |
Package 1 width | 4.8 cm | |
Package 1 Length | 6.2 cm | |
Unit Type of Package 2 | S02 | |
Number of Units in Package 2 | 40 | |
Package 2 Weight | 9.335 kg | |
Package 2 Height | 15 cm | |
Package 2 width | 30 cm | |
Package 2 Length | 40 cm | |
Unit Type of Package 3 | P06 | |
Number of Units in Package 3 | 640 | |
Package 3 Weight | 156.58 kg | |
Package 3 Height | 80 cm | |
Package 3 width | 80 cm | |
Package 3 Length | 60 cm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
REACh free of SVHC | Yes | |
EU RoHS Directive | Compliant EU RoHS Declaration | |
Toxic heavy metal free | Yes | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | China RoHS declaration Pro-active China RoHS declaration (out of China RoHS legal scope) | |
Environmental Disclosure | ||
Circularity Profile | ||
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | |
California proposition 65 | WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov |
Warranty | 12 months |
---|