Schneider Tesys K Schneider Electric Tesys K Control Relay - 3 NO 1 NC - 690 V - 220 230V AC Coil - CA2KN31M7
Rp 191,514.00
48.00 %
Rp 368,298.00
Rp 368,298.00
Option not available
[Deskripsi] TeSys D, K dan SK Relai Kontrol adalah rentang yang mencakup relai, relai kontrol mini, blok kontak bantu, modul penekan koil, dan aksesori. [Spesifikasi] 1. pole contact composition : 3 NO + 2 NC 2. [Ue] rated operational voltage : <= 690 V <= 400 Hz 3. control circuit type : AC at 50/60 Hz 4. [Uc] control circuit voltage : 220...230 V AC 50/60 Hz 5. [Ith] conventional free air thermal current : 10 A (at 50 °C) 6. height : 58 mm 7. width : 45 mm 8. depth : 57 mm 9. net weight : 0.18 kg
| range | TeSys | |
|---|---|---|
| product name | TeSys CAK | |
| product or component type | Control relay | |
| device short name | CA2K | |
| contactor application | Control circuit | |
| utilisation category | AC-15 DC-13 | |
| pole contact composition | 3 NO + 1 NC | |
| [Ue] rated operational voltage | <= 690 V <= 400 Hz | |
| control circuit type | AC at 50/60 Hz | |
| [Uc] control circuit voltage | 220...230 V AC 50/60 Hz |
| [Ith] conventional free air thermal current | 10 A (at 50 °C) | |
|---|---|---|
| Irms rated making capacity | 110 A conforming to IEC 60947 | |
| associated fuse rating | 10 A gG conforming to IEC 60947 10 A gG conforming to VDE 0660 | |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947 750 V conforming to VDE 0110 group C 690 V conforming to BS 5424 600 V conforming to CSA C22.2 No 14 | |
| mounting support | Plate Rail | |
| connections - terminals | Screw clamp terminals 1 cable(s) 1.5…4 mm²solid Screw clamp terminals 2 cable(s) 1.5…4 mm²solid Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible with cable end Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end Screw clamp terminals 1 cable(s) 0.34…1.5 mm²flexible with cable end Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible without cable end | |
| tightening torque | 1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm 1.3 N.m - on screw clamp terminals - with screwdriver Philips No 26 mm | |
| control circuit voltage limits | Drop-out: 0.2...0.75 Uc (at <50 °C) Operational: 0.8...1.15 Uc (at <50 °C) | |
| operating time | 10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing 15...25 ms coil de-energisation and NC closing 5...15 ms coil energisation and NC opening | |
| mechanical durability | 10 Mcycles | |
| maximum operating rate | 10000 cyc/h | |
| immunity to microbreaks | 2 ms | |
| inrush power in VA | 30 VA (at 20 °C) | |
| hold-in power consumption in VA | 4.5 VA (at 20 °C) | |
| heat dissipation | 1.3 W | |
| minimum switching voltage | 17 V | |
| minimum switching current | 5 mA | |
| non overlap distance | 0.5 mm | |
| insulation resistance | > 10 MOhm | |
| height | 58 mm | |
| width | 45 mm | |
| depth | 57 mm | |
| net weight | 0.18 kg |
| standards | BS 5424 IEC 60947 NF C 63-140 VDE 0660 | |
|---|---|---|
| product certifications | UL CSA | |
| IP degree of protection | IP2x | |
| protective treatment | TC conforming to IEC 60068 | |
| ambient air temperature for operation | -25…50 °C | |
| ambient air temperature for storage | -50…80 °C | |
| operating altitude | 2000 m without derating | |
| flame retardance | V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102 | |
| mechanical robustness | Vibrations contactor open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor open: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed: 15 Gn for 11 ms conforming to IEC 60068-2-27 |
| Unit Type of Package 1 | PCE | |
|---|---|---|
| Number of Units in Package 1 | 1 | |
| Package 1 Weight | 177.41 g | |
| Package 1 Height | 4.5 cm | |
| Package 1 width | 5 cm | |
| Package 1 Length | 6.5 cm |
| Sustainable offer status | Green Premium product | |
|---|---|---|
| REACh Regulation | ||
| REACh free of SVHC | Yes | |
| EU RoHS Directive | Compliant EU RoHS Declaration | |
| Toxic heavy metal free | Yes | |
| Mercury free | Yes | |
| RoHS exemption information | ||
| China RoHS Regulation | China RoHS declaration Pro-active China RoHS declaration (out of China RoHS legal scope) | |
| Environmental Disclosure | ||
| Circularity Profile | ||
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | |
| California proposition 65 | WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov |
| Warranty | 12 months |
|---|
[Deskripsi] TeSys D, K dan SK Relai Kontrol adalah rentang yang mencakup relai, relai kontrol mini, blok kontak bantu, modul penekan koil, dan aksesori. [Spesifikasi] 1. pole contact composition : 3 NO + 2 NC 2. [Ue] rated operational voltage : <= 690 V <= 400 Hz 3. control circuit type : AC at 50/60 Hz 4. [Uc] control circuit voltage : 220...230 V AC 50/60 Hz 5. [Ith] conventional free air thermal current : 10 A (at 50 °C) 6. height : 58 mm 7. width : 45 mm 8. depth : 57 mm 9. net weight : 0.18 kg
| range | TeSys | |
|---|---|---|
| product name | TeSys CAK | |
| product or component type | Control relay | |
| device short name | CA2K | |
| contactor application | Control circuit | |
| utilisation category | AC-15 DC-13 | |
| pole contact composition | 3 NO + 1 NC | |
| [Ue] rated operational voltage | <= 690 V <= 400 Hz | |
| control circuit type | AC at 50/60 Hz | |
| [Uc] control circuit voltage | 220...230 V AC 50/60 Hz |
| [Ith] conventional free air thermal current | 10 A (at 50 °C) | |
|---|---|---|
| Irms rated making capacity | 110 A conforming to IEC 60947 | |
| associated fuse rating | 10 A gG conforming to IEC 60947 10 A gG conforming to VDE 0660 | |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947 750 V conforming to VDE 0110 group C 690 V conforming to BS 5424 600 V conforming to CSA C22.2 No 14 | |
| mounting support | Plate Rail | |
| connections - terminals | Screw clamp terminals 1 cable(s) 1.5…4 mm²solid Screw clamp terminals 2 cable(s) 1.5…4 mm²solid Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible with cable end Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end Screw clamp terminals 1 cable(s) 0.34…1.5 mm²flexible with cable end Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible without cable end | |
| tightening torque | 1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm 1.3 N.m - on screw clamp terminals - with screwdriver Philips No 26 mm | |
| control circuit voltage limits | Drop-out: 0.2...0.75 Uc (at <50 °C) Operational: 0.8...1.15 Uc (at <50 °C) | |
| operating time | 10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing 15...25 ms coil de-energisation and NC closing 5...15 ms coil energisation and NC opening | |
| mechanical durability | 10 Mcycles | |
| maximum operating rate | 10000 cyc/h | |
| immunity to microbreaks | 2 ms | |
| inrush power in VA | 30 VA (at 20 °C) | |
| hold-in power consumption in VA | 4.5 VA (at 20 °C) | |
| heat dissipation | 1.3 W | |
| minimum switching voltage | 17 V | |
| minimum switching current | 5 mA | |
| non overlap distance | 0.5 mm | |
| insulation resistance | > 10 MOhm | |
| height | 58 mm | |
| width | 45 mm | |
| depth | 57 mm | |
| net weight | 0.18 kg |
| standards | BS 5424 IEC 60947 NF C 63-140 VDE 0660 | |
|---|---|---|
| product certifications | UL CSA | |
| IP degree of protection | IP2x | |
| protective treatment | TC conforming to IEC 60068 | |
| ambient air temperature for operation | -25…50 °C | |
| ambient air temperature for storage | -50…80 °C | |
| operating altitude | 2000 m without derating | |
| flame retardance | V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102 | |
| mechanical robustness | Vibrations contactor open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor open: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed: 15 Gn for 11 ms conforming to IEC 60068-2-27 |
| Unit Type of Package 1 | PCE | |
|---|---|---|
| Number of Units in Package 1 | 1 | |
| Package 1 Weight | 177.41 g | |
| Package 1 Height | 4.5 cm | |
| Package 1 width | 5 cm | |
| Package 1 Length | 6.5 cm |
| Sustainable offer status | Green Premium product | |
|---|---|---|
| REACh Regulation | ||
| REACh free of SVHC | Yes | |
| EU RoHS Directive | Compliant EU RoHS Declaration | |
| Toxic heavy metal free | Yes | |
| Mercury free | Yes | |
| RoHS exemption information | ||
| China RoHS Regulation | China RoHS declaration Pro-active China RoHS declaration (out of China RoHS legal scope) | |
| Environmental Disclosure | ||
| Circularity Profile | ||
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | |
| California proposition 65 | WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov |
| Warranty | 12 months |
|---|