• Sign up now and get discount up to 47%

Schneider Compact smart relay Zelio Logic - “discovery” pack - 12 I O - 24 V DC

Rp 4.119.321,00 Rp 2.348.012,00 2348012 IDR

Rp 4.119.321,00

Option not available

    This combination does not exist.

    Add to Cart

    Schneider Compact smart relay Zelio Logic - “discovery” pack - 12 I O - 24 V DC
    Terjual 0
    0 (0 Rating)
    Ulasan (0)

    Rp 2.348.012,00
    43.00 % Rp 4.119.321,00 2348012 IDR

    Rp 4.119.321,00

    Option not available

    Atur Jumlah & Catatan
    Stock Total: 5
    Spesifikasi
    Main (see above)
    range of product
    Zelio Logic
    product or component type
    Compact discovery packs
    discrete input number
    8 conforming to EN/IEC 61131-2 type 1
    number of outputs
    4 relay
    Complementary (see above)
    kit composition
    SR2B121BD
    Cable PC SR2USB01 for connection to PC
    Zelio Soft 2 programming software CD-ROM
    input/output number
    12
    local display
    With
    number or control scheme lines
    120 with ladder programming
    0…200 with FBD programming
    cycle time
    6…90 ms
    backup time
    10 years at 25 °C
    clock drift
    12 min/year at 0…55 °C
    6 s/month at 25 °C
    checks
    Program memory on each power up
    [Us] rated supply voltage
    24 V
    supply voltage limits
    19.2…30 V
    maximum supply current
    100 mA (without extension)
    power dissipation in W
    3 W without extension
    reverse polarity protection
    With
    discrete input type
    Resistive
    discrete input voltage
    24 V DC
    discrete input current
    4 mA
    counting frequency
    1 kHz for discrete input
    voltage state 1 guaranteed
    >= 15 V for I1...IA and IH...IR discrete input circuit
    >= 15 V for IB...IG used as discrete input circuit
    voltage state 0 guaranteed
    <= 5 V for I1...IA and IH...IR discrete input circuit
    <= 5 V for IB...IG used as discrete input circuit
    current state 1 guaranteed
    >= 1.2 mA (IB...IG used as discrete input circuit)
    >= 2.2 mA (I1...IA and IH...IR discrete input circuit)
    current state 0 guaranteed
    <= 0.5 mA (IB...IG used as discrete input circuit)
    <= 0.75 mA (I1...IA and IH...IR discrete input circuit)
    input compatibility
    3-wire proximity sensors PNP for discrete input
    analogue input number
    4
    analogue input type
    Common mode
    analogue input range
    0...10 V
    0...24 V
    maximum permissible voltage
    30 V for analogue input circuit
    analogue input resolution
    8 bits
    LSB value
    39 mV for analogue input circuit
    conversion time
    Smart relay cycle time for analogue input circuit
    conversion error
    +/- 5 % at 25 °C for analogue input circuit
    +/- 6.2 % at 55 °C for analogue input circuit
    repeat accuracy
    +/- 2 % at 55 °C for analogue input circuit
    operating distance
    10 m between stations, with screened cable (sensor not isolated) for analogue input circuit
    input impedance
    12 kOhm for IB...IG used as analogue input circuit
    12 kOhm for IB...IG used as discrete input circuit
    7.4 kOhm for I1...IA and IH...IR discrete input circuit
    output voltage limits
    24...250 V AC (relay output)
    5...30 V DC (relay output)
    contacts type and composition
    NO for relay output
    output thermal current
    8 A for all 4 outputs for relay output
    electrical durability
    AC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
    AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1
    DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
    DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1
    switching capacity in mA
    >= 10 mA at 12 V (relay output)
    operating rate in Hz
    0.1 Hz (at Ie) for relay output
    10 Hz (no load) for relay output
    mechanical durability
    10000000 cycles for relay output
    [Uimp] rated impulse withstand voltage
    4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1
    clock
    With
    response time
    10 ms (from state 0 to state 1) for relay output
    5 ms (from state 1 to state 0) for relay output
    connections - terminals
    Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 25...AWG 14) semi-solid
    Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 25...AWG 14) solid
    Screw terminals, 1 x 0.25...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end
    Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) solid
    Screw terminals, 2 x 0.25...2 x 0.75 mm² (AWG 24...AWG 18) flexible with cable end
    tightening torque
    0.5 N.m
    overvoltage category
    III conforming to EN/IEC 60664-1
    net weight
    0.7 kg
    Environment (see above)
    immunity to microbreaks
    1 ms
    product certifications
    CSA
    C-Tick
    UL
    GOST
    GL
    standards
    EN/IEC 61000-4-4 level 3
    EN/IEC 61000-4-12
    EN/IEC 61000-4-5
    EN/IEC 60068-2-6 Fc
    EN/IEC 61000-4-2 level 3
    EN/IEC 61000-4-6 level 3
    EN/IEC 61000-4-3
    EN/IEC 61000-4-11
    EN/IEC 60068-2-27 Ea
    IP degree of protection
    IP20 (terminal block) conforming to IEC 60529
    IP40 (front panel) conforming to IEC 60529
    environmental characteristic
    EMC directive conforming to EN/IEC 61000-6-2
    EMC directive conforming to EN/IEC 61000-6-3
    EMC directive conforming to EN/IEC 61000-6-4
    EMC directive conforming to EN/IEC 61131-2 zone B
    Low voltage directive conforming to EN/IEC 61131-2
    disturbance radiated/conducted
    Class B conforming to EN 55022-11 group 1
    pollution degree
    2 conforming to EN/IEC 61131-2
    ambient air temperature for operation
    -20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
    -20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
    ambient air temperature for storage
    -40…70 °C
    operating altitude
    2000 m
    maximum altitude transport
    3048 m
    relative humidity
    95 % without condensation or dripping water
    Packing Units (see above)
    Unit Type of Package 1
    PCE
    Number of Units in Package 1
    1
    Package 1 Weight
    488 g
    Package 1 Height
    6.5 cm
    Package 1 width
    15.5 cm
    Package 1 Length
    23.5 cm
    Offer Sustainability (see above)
    Sustainable offer status
    Green Premium product
    REACh Regulation
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    PVC free
    Yes
    Contractual warranty (see above)
    Warranty
    12 months

    Filter By

    Product Public Price Discount Guaranteed Stock QTY Action
    Rp 1.318.546,00 100.00 % 14
    Rp 2.201.796,00 100.00 % 2
    Rp 1.264.197,00 100.00 % 8
    Rp 3.323.826,00 100.00 % 9
    Rp 3.022.724,00 100.00 % 2
    Rp 3.323.826,00 100.00 % 5
    HOT PROMO
    Main (see above)
    range of product
    Zelio Logic
    product or component type
    Compact discovery packs
    discrete input number
    8 conforming to EN/IEC 61131-2 type 1
    number of outputs
    4 relay
    Complementary (see above)
    kit composition
    SR2B121BD
    Cable PC SR2USB01 for connection to PC
    Zelio Soft 2 programming software CD-ROM
    input/output number
    12
    local display
    With
    number or control scheme lines
    120 with ladder programming
    0…200 with FBD programming
    cycle time
    6…90 ms
    backup time
    10 years at 25 °C
    clock drift
    12 min/year at 0…55 °C
    6 s/month at 25 °C
    checks
    Program memory on each power up
    [Us] rated supply voltage
    24 V
    supply voltage limits
    19.2…30 V
    maximum supply current
    100 mA (without extension)
    power dissipation in W
    3 W without extension
    reverse polarity protection
    With
    discrete input type
    Resistive
    discrete input voltage
    24 V DC
    discrete input current
    4 mA
    counting frequency
    1 kHz for discrete input
    voltage state 1 guaranteed
    >= 15 V for I1...IA and IH...IR discrete input circuit
    >= 15 V for IB...IG used as discrete input circuit
    voltage state 0 guaranteed
    <= 5 V for I1...IA and IH...IR discrete input circuit
    <= 5 V for IB...IG used as discrete input circuit
    current state 1 guaranteed
    >= 1.2 mA (IB...IG used as discrete input circuit)
    >= 2.2 mA (I1...IA and IH...IR discrete input circuit)
    current state 0 guaranteed
    <= 0.5 mA (IB...IG used as discrete input circuit)
    <= 0.75 mA (I1...IA and IH...IR discrete input circuit)
    input compatibility
    3-wire proximity sensors PNP for discrete input
    analogue input number
    4
    analogue input type
    Common mode
    analogue input range
    0...10 V
    0...24 V
    maximum permissible voltage
    30 V for analogue input circuit
    analogue input resolution
    8 bits
    LSB value
    39 mV for analogue input circuit
    conversion time
    Smart relay cycle time for analogue input circuit
    conversion error
    +/- 5 % at 25 °C for analogue input circuit
    +/- 6.2 % at 55 °C for analogue input circuit
    repeat accuracy
    +/- 2 % at 55 °C for analogue input circuit
    operating distance
    10 m between stations, with screened cable (sensor not isolated) for analogue input circuit
    input impedance
    12 kOhm for IB...IG used as analogue input circuit
    12 kOhm for IB...IG used as discrete input circuit
    7.4 kOhm for I1...IA and IH...IR discrete input circuit
    output voltage limits
    24...250 V AC (relay output)
    5...30 V DC (relay output)
    contacts type and composition
    NO for relay output
    output thermal current
    8 A for all 4 outputs for relay output
    electrical durability
    AC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
    AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1
    DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
    DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1
    switching capacity in mA
    >= 10 mA at 12 V (relay output)
    operating rate in Hz
    0.1 Hz (at Ie) for relay output
    10 Hz (no load) for relay output
    mechanical durability
    10000000 cycles for relay output
    [Uimp] rated impulse withstand voltage
    4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1
    clock
    With
    response time
    10 ms (from state 0 to state 1) for relay output
    5 ms (from state 1 to state 0) for relay output
    connections - terminals
    Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 25...AWG 14) semi-solid
    Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 25...AWG 14) solid
    Screw terminals, 1 x 0.25...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end
    Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) solid
    Screw terminals, 2 x 0.25...2 x 0.75 mm² (AWG 24...AWG 18) flexible with cable end
    tightening torque
    0.5 N.m
    overvoltage category
    III conforming to EN/IEC 60664-1
    net weight
    0.7 kg
    Environment (see above)
    immunity to microbreaks
    1 ms
    product certifications
    CSA
    C-Tick
    UL
    GOST
    GL
    standards
    EN/IEC 61000-4-4 level 3
    EN/IEC 61000-4-12
    EN/IEC 61000-4-5
    EN/IEC 60068-2-6 Fc
    EN/IEC 61000-4-2 level 3
    EN/IEC 61000-4-6 level 3
    EN/IEC 61000-4-3
    EN/IEC 61000-4-11
    EN/IEC 60068-2-27 Ea
    IP degree of protection
    IP20 (terminal block) conforming to IEC 60529
    IP40 (front panel) conforming to IEC 60529
    environmental characteristic
    EMC directive conforming to EN/IEC 61000-6-2
    EMC directive conforming to EN/IEC 61000-6-3
    EMC directive conforming to EN/IEC 61000-6-4
    EMC directive conforming to EN/IEC 61131-2 zone B
    Low voltage directive conforming to EN/IEC 61131-2
    disturbance radiated/conducted
    Class B conforming to EN 55022-11 group 1
    pollution degree
    2 conforming to EN/IEC 61131-2
    ambient air temperature for operation
    -20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
    -20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
    ambient air temperature for storage
    -40…70 °C
    operating altitude
    2000 m
    maximum altitude transport
    3048 m
    relative humidity
    95 % without condensation or dripping water
    Packing Units (see above)
    Unit Type of Package 1
    PCE
    Number of Units in Package 1
    1
    Package 1 Weight
    488 g
    Package 1 Height
    6.5 cm
    Package 1 width
    15.5 cm
    Package 1 Length
    23.5 cm
    Offer Sustainability (see above)
    Sustainable offer status
    Green Premium product
    REACh Regulation
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    PVC free
    Yes
    Contractual warranty (see above)
    Warranty
    12 months