Spesifikasi
| range of product | Telemecanique Emergency stop rope pull switches XY2C | |
|---|---|---|
| product or component type | Latching emergency stop rope pull switch | |
| device short name | XY2CE | |
| housing colour | Red RAL 3000 | |
| overvoltage category | Class I conforming to EN/IEC 61140 Class I conforming to NF C 20-030 |
| local signalling | Without pilot light | |
|---|---|---|
| number of cables | 1 | |
| trigger cable maximum length | 70 m | |
| body material | Zamak | |
| cover material | Stainless steel | |
| reset | By booted push-button | |
| contacts type and composition | 1 NC + 1 NO | |
| contact operation | Slow-break | |
| trigger cable anchor point | RH side | |
| connections - terminals | Screw clamp terminal, 1 x 0.5...2 x 1.5 mm² | |
| tightening torque | 0.8…1.2 N.m | |
| cable entry number | 3 plain hole for Pg 13.5 or ISO M20 cable gland | |
| safety level | Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508 | |
| safety reliability data | B10d = 300000 conforming to IEC 60947-5-5 value given for a life time of 20 years limited by mechanical or contact wear | |
| marking | CE | |
| mechanical durability | 60000 cycles | |
| distance between cable supports | 5 m | |
| [Ie] rated operational current | 3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 appendix A 0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 appendix A | |
| [Ithe] conventional enclosed thermal current | 10 A | |
| [Ui] rated insulation voltage | 500 V (pollution degree 3) conforming to EN/IEC 60947-1 300 V conforming to UL 508 300 V conforming to CSA C22.2 No 14 | |
| [Uimp] rated impulse withstand voltage | 6 kV EN/IEC 60947-1 | |
| positive opening | With conforming to EN/IEC 60947-5-1 | |
| maximum resistance across terminals | 25 MOhm conforming to EN/IEC 60255-7 category 3 25 MOhm conforming to NF C 93-050 method A | |
| short-circuit protection | 10 A cartridge fuse type gG conforming to EN/IEC 60269 | |
| terminals description ISO n°1 | (13-14)NO (21-22)NC | |
| net weight | 1.45 kg | |
| compatibility code | XY2CE |
| standards | CSA C22.2 No 14 EN/IEC 60947-5-1 EN/IEC 60947-5-5 UL 508 EN/ISO 13850 Work equipment directive 2009/104/EC EN/IEC 60204-1 Machinery directive 2006/42/EC | |
|---|---|---|
| product certifications | UL category NISD emergency stop devices CSA CCC | |
| protective treatment | TC | |
| ambient air temperature for operation | -25…70 °C | |
| ambient air temperature for storage | -40…70 °C | |
| vibration resistance | 10 gn (f= 10…300 Hz) conforming to EN/IEC 60068-2-6 | |
| shock resistance | 50 gn 11 ms conforming to EN/IEC 60068-2-27 | |
| IP degree of protection | IP66 conforming to IEC 60529 |
| Unit Type of Package 1 | PCE | |
|---|---|---|
| Number of Units in Package 1 | 1 | |
| Package 1 Weight | 1.552 kg | |
| Package 1 Height | 9 cm | |
| Package 1 width | 16 cm | |
| Package 1 Length | 20 cm | |
| Unit Type of Package 2 | S03 | |
| Number of Units in Package 2 | 6 | |
| Package 2 Weight | 9.849 kg | |
| Package 2 Height | 30 cm | |
| Package 2 width | 30 cm | |
| Package 2 Length | 40 cm | |
| Unit Type of Package 3 | P06 | |
| Number of Units in Package 3 | 48 | |
| Package 3 Weight | 88.7 kg | |
| Package 3 Height | 80 cm | |
| Package 3 width | 80 cm | |
| Package 3 Length | 60 cm |
| Sustainable offer status | Green Premium product | |
|---|---|---|
| REACh Regulation | ||
| EU RoHS Directive | Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration | |
| Mercury free | Yes | |
| RoHS exemption information | ||
| Environmental Disclosure |
| Warranty | 12 months |
|---|
Filter By
| Product | Public Price | Discount | Guaranteed Stock | QTY | Action |
|---|
| range of product | Telemecanique Emergency stop rope pull switches XY2C | |
|---|---|---|
| product or component type | Latching emergency stop rope pull switch | |
| device short name | XY2CE | |
| housing colour | Red RAL 3000 | |
| overvoltage category | Class I conforming to EN/IEC 61140 Class I conforming to NF C 20-030 |
| local signalling | Without pilot light | |
|---|---|---|
| number of cables | 1 | |
| trigger cable maximum length | 70 m | |
| body material | Zamak | |
| cover material | Stainless steel | |
| reset | By booted push-button | |
| contacts type and composition | 1 NC + 1 NO | |
| contact operation | Slow-break | |
| trigger cable anchor point | RH side | |
| connections - terminals | Screw clamp terminal, 1 x 0.5...2 x 1.5 mm² | |
| tightening torque | 0.8…1.2 N.m | |
| cable entry number | 3 plain hole for Pg 13.5 or ISO M20 cable gland | |
| safety level | Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508 | |
| safety reliability data | B10d = 300000 conforming to IEC 60947-5-5 value given for a life time of 20 years limited by mechanical or contact wear | |
| marking | CE | |
| mechanical durability | 60000 cycles | |
| distance between cable supports | 5 m | |
| [Ie] rated operational current | 3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 appendix A 0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 appendix A | |
| [Ithe] conventional enclosed thermal current | 10 A | |
| [Ui] rated insulation voltage | 500 V (pollution degree 3) conforming to EN/IEC 60947-1 300 V conforming to UL 508 300 V conforming to CSA C22.2 No 14 | |
| [Uimp] rated impulse withstand voltage | 6 kV EN/IEC 60947-1 | |
| positive opening | With conforming to EN/IEC 60947-5-1 | |
| maximum resistance across terminals | 25 MOhm conforming to EN/IEC 60255-7 category 3 25 MOhm conforming to NF C 93-050 method A | |
| short-circuit protection | 10 A cartridge fuse type gG conforming to EN/IEC 60269 | |
| terminals description ISO n°1 | (13-14)NO (21-22)NC | |
| net weight | 1.45 kg | |
| compatibility code | XY2CE |
| standards | CSA C22.2 No 14 EN/IEC 60947-5-1 EN/IEC 60947-5-5 UL 508 EN/ISO 13850 Work equipment directive 2009/104/EC EN/IEC 60204-1 Machinery directive 2006/42/EC | |
|---|---|---|
| product certifications | UL category NISD emergency stop devices CSA CCC | |
| protective treatment | TC | |
| ambient air temperature for operation | -25…70 °C | |
| ambient air temperature for storage | -40…70 °C | |
| vibration resistance | 10 gn (f= 10…300 Hz) conforming to EN/IEC 60068-2-6 | |
| shock resistance | 50 gn 11 ms conforming to EN/IEC 60068-2-27 | |
| IP degree of protection | IP66 conforming to IEC 60529 |
| Unit Type of Package 1 | PCE | |
|---|---|---|
| Number of Units in Package 1 | 1 | |
| Package 1 Weight | 1.552 kg | |
| Package 1 Height | 9 cm | |
| Package 1 width | 16 cm | |
| Package 1 Length | 20 cm | |
| Unit Type of Package 2 | S03 | |
| Number of Units in Package 2 | 6 | |
| Package 2 Weight | 9.849 kg | |
| Package 2 Height | 30 cm | |
| Package 2 width | 30 cm | |
| Package 2 Length | 40 cm | |
| Unit Type of Package 3 | P06 | |
| Number of Units in Package 3 | 48 | |
| Package 3 Weight | 88.7 kg | |
| Package 3 Height | 80 cm | |
| Package 3 width | 80 cm | |
| Package 3 Length | 60 cm |
| Sustainable offer status | Green Premium product | |
|---|---|---|
| REACh Regulation | ||
| EU RoHS Directive | Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration | |
| Mercury free | Yes | |
| RoHS exemption information | ||
| Environmental Disclosure |
| Warranty | 12 months |
|---|
HOT PROMO