• Sign up now and get discount up to 47%

Schneider Schneider Electric Easypact EZC MCCB EZC250H 160A 3P - EZC250H3160

# of Pole : 3

Arus Nominal (In) : 160A

Rp 3.121.320,00 Rp 1.591.873,00 1591873 IDR

Rp 3.121.320,00

Option not available

  • # of Pole
  • Arus Nominal (In)

This combination does not exist.

Add to Cart

Schneider Schneider Electric Easypact EZC MCCB EZC250H 160A 3P - EZC250H3160
Terjual 0
0 (0 Rating)
Ulasan (0)

Rp 1.591.873,00
49.00 % Rp 3.121.320,00 1591873 IDR

Rp 3.121.320,00

Option not available

Atur Jumlah & Catatan
Stock Total: 5

# of Pole : 3

Arus Nominal (In) : 160A

Spesifikasi
Main (see above)
range of product
EasyPact
product or component type
Circuit breaker
device short name
Easypact EZC250H
circuit breaker name
Easypact EZC250H
device application
Distribution
poles description
3P
protected poles description
3t
network type
AC
DC
network frequency
50/60 Hz
[In] rated current
250 A at 40 °C
[Ui] rated insulation voltage
690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947-2
[Ue] rated operational voltage
550 V AC 50/60 Hz conforming to IEC 60947-2
250 V DC conforming to IEC 60947-2
breaking capacity code
H
breaking capacity
10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
30 kA Icu at 125 V DC 1P conforming to IEC 60947-2
30 kA Icu at 250 V DC 2P conforming to IEC 60947-2
36 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2
36 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2
85 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2
85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity
5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2
15 kA at 125 V DC conforming to IEC 60947-2
15 kA at 250 V DC conforming to IEC 60947-2
18 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2
18 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
42.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2
42.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2
suitability for isolation
Yes conforming to IEC 60947-2
utilisation category
Category A
trip unit name
TM-D
trip unit technology
Thermal-magnetic
trip unit rating
160 A at 50 °C
protection type
Short-circuit protection
Overload protection
pollution degree
3 conforming to IEC 60664-1
3 conforming to IEC 947-1
Complementary (see above)
control type
Toggle
mounting mode
Fixed
mounting support
Backplate
upside connection
Front
downside connection
Front
mechanical durability
10000 cycles
electrical durability
Category A: 5000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
connection pitch
35 mm
local signalling
Positive contact indication
neutral protection setting
Without protection
earth-leakage protection
Without
height
165 mm
width
105 mm
depth
60 mm
Environment (see above)
standards
EN/IEC 60947-1
EN/IEC 60947-2
GB/T 14048.2
IP degree of protection
IP20 conforming to IEC 60529
IK degree of protection
IK07 conforming to IEC 62262
ambient air temperature for operation
-25…70 °C
ambient air temperature for storage
-35…85 °C
Packing Units (see above)
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Weight
1.49 kg
Package 1 Height
11 cm
Package 1 width
11.6 cm
Package 1 Length
18 cm
Offer Sustainability (see above)
Sustainable offer status
Green Premium product
REACh Regulation
REACh free of SVHC
Yes
EU RoHS Directive
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
China RoHS Regulation
Environmental Disclosure
WEEE
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Contractual warranty (see above)
Warranty
12 months

Specifications for Schneider Schneider Electric Easypact EZC MCCB EZC250H 160A 3P - EZC250H3160

# of Pole 3
Arus Nominal (In) 160A

Filter By

Product Public Price Discount Guaranteed Stock QTY Action
Rp 3.582.846,00 100.00 % 2
  • # of Pole
  • Arus Nominal (In)
Rp 3.445.850,00 100.00 % 2
  • # of Pole
  • Arus Nominal (In)
Rp 3.375.654,00 100.00 % 2
  • # of Pole
  • Arus Nominal (In)
Rp 1.735.096,00 100.00 % 3
  • # of Pole
  • Arus Nominal (In)
Rp 1.735.096,00 100.00 % 2
  • # of Pole
  • Arus Nominal (In)
Rp 1.735.096,00 100.00 % 11
  • # of Pole
  • Arus Nominal (In)
HOT PROMO
Main (see above)
range of product
EasyPact
product or component type
Circuit breaker
device short name
Easypact EZC250H
circuit breaker name
Easypact EZC250H
device application
Distribution
poles description
3P
protected poles description
3t
network type
AC
DC
network frequency
50/60 Hz
[In] rated current
250 A at 40 °C
[Ui] rated insulation voltage
690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947-2
[Ue] rated operational voltage
550 V AC 50/60 Hz conforming to IEC 60947-2
250 V DC conforming to IEC 60947-2
breaking capacity code
H
breaking capacity
10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
30 kA Icu at 125 V DC 1P conforming to IEC 60947-2
30 kA Icu at 250 V DC 2P conforming to IEC 60947-2
36 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2
36 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2
85 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2
85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity
5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2
15 kA at 125 V DC conforming to IEC 60947-2
15 kA at 250 V DC conforming to IEC 60947-2
18 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2
18 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
42.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2
42.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2
suitability for isolation
Yes conforming to IEC 60947-2
utilisation category
Category A
trip unit name
TM-D
trip unit technology
Thermal-magnetic
trip unit rating
160 A at 50 °C
protection type
Short-circuit protection
Overload protection
pollution degree
3 conforming to IEC 60664-1
3 conforming to IEC 947-1
Complementary (see above)
control type
Toggle
mounting mode
Fixed
mounting support
Backplate
upside connection
Front
downside connection
Front
mechanical durability
10000 cycles
electrical durability
Category A: 5000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
connection pitch
35 mm
local signalling
Positive contact indication
neutral protection setting
Without protection
earth-leakage protection
Without
height
165 mm
width
105 mm
depth
60 mm
Environment (see above)
standards
EN/IEC 60947-1
EN/IEC 60947-2
GB/T 14048.2
IP degree of protection
IP20 conforming to IEC 60529
IK degree of protection
IK07 conforming to IEC 62262
ambient air temperature for operation
-25…70 °C
ambient air temperature for storage
-35…85 °C
Packing Units (see above)
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Weight
1.49 kg
Package 1 Height
11 cm
Package 1 width
11.6 cm
Package 1 Length
18 cm
Offer Sustainability (see above)
Sustainable offer status
Green Premium product
REACh Regulation
REACh free of SVHC
Yes
EU RoHS Directive
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
China RoHS Regulation
Environmental Disclosure
WEEE
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Contractual warranty (see above)
Warranty
12 months