[Deskripsi] TeSys K Relai Kontrol adalah rentang yang mencakup relai, relai kontrol mini, blok kontak bantu, modul penekan koil, dan aksesori. [Spesifikasi] 1. pole contact composition : 2 NO + 2 NC 2. mounting location : Front 3. [Ui] rated insulation voltage : -690 V - for control circuit conforming to BS 5424 -690 V - for control circuit conforming to IEC 60947 -750 V - for control circuit conforming to VDE 0010 group C -600 V - for control circuit conforming to CSA C22.2 4. [Ue] rated operational voltage : <= 690 V AC <= 400 Hz 5. [Ith] conventional free air thermal current : 10 A (at 50 °C) 6. Irms rated making capacity : 110 A at <= 690 V AC conforming to IEC 60947 7. permissible short-time rating : -80 A 1 s -60 A 500 ms -110 A 100 ms 8. associated fuse rating : -10 A gG at <= 690 V conforming to IEC 60947 -10 A gG at <= 690 V conforming to VDE 0660 9. minimum switching current : 5 mA 10. minimum switching voltage : 17 V 11. non overlap distance : 0.5 mm 12. insulation resistance : > 10 MOhm for control circuit 13. tightening torque : 1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2 14. depth : 35 mm 15. net weight : 0.045 kg
range | TeSys | |
---|---|---|
product name | TeSys K | |
product or component type | Auxiliary contact block | |
device short name | LA1 | |
range compatibility | TeSys K LC1K TeSys K CA2K TeSys K CA3K | |
mounting location | Front | |
pole contact composition | 2 NO + 2 NC | |
Contacts operation | Instantaneous | |
[Ue] rated operational voltage | 690 V AC 25...400 Hz | |
[Ie] rated operational current | 6 A at 120 V AC-15 1.04 A at 690 V AC-15 0.55 A at 125 V DC-13 0.1 A at 600 V DC-13 | |
[Ui] rated insulation voltage | 690 V conforming to IEC 60947-5-1 600 V conforming to UL 60947-5-1 600 V conforming to CSA C22.2 No 60947-5-1 | |
[Ith] conventional free air thermal current | 10 A (at 50 °C) | |
standards | EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 | |
product certifications | IECEE CB Scheme UL CSA CCC |
Irms rated making capacity | 110 A at <= 690 V AC conforming to IEC 60947 | |
---|---|---|
permissible short-time rating | 80 A 1 s 60 A 500 ms 110 A 100 ms | |
associated fuse rating | 10 A gG at <= 690 V conforming to IEC 60947 | |
minimum switching current | 5 mA | |
minimum switching voltage | 17 V | |
non overlap distance | 0.5 mm | |
insulation resistance | > 10 MOhm | |
connections - terminals | Screw clamp terminals 1 cable(s) 0.34…1.5 mm²flexible with cable end Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end Screw clamp terminals 1 cable(s) 1.5…4 mm²rigid Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end Screw clamp terminals 2 cable(s) 1.5…4 mm²rigid | |
tightening torque | 1.3 N.m - with screwdriver Philips No 2 | |
height | 30 mm | |
width | 38 mm | |
depth | 35 mm | |
net weight | 0.045 kg |
environmental characteristic | Normal environment | |
---|---|---|
IP degree of protection | IP20 conforming to IEC 60529 | |
protective treatment | TC conforming to IEC 60068 | |
ambient air temperature for storage | -50…80 °C | |
ambient air temperature for operation | -25…50 °C | |
operating altitude | 2000 m |
Unit Type of Package 1 | PCE | |
---|---|---|
Number of Units in Package 1 | 1 | |
Package 1 Weight | 30 g | |
Package 1 Height | 3.295 cm | |
Package 1 width | 3.823 cm | |
Package 1 Length | 3.917 cm |
REACh Regulation | ||
---|---|---|
REACh free of SVHC | Yes | |
EU RoHS Directive | Compliant EU RoHS Declaration | |
Toxic heavy metal free | Yes | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | China RoHS declaration Pro-active China RoHS declaration (out of China RoHS legal scope) | |
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
[Deskripsi] TeSys K Relai Kontrol adalah rentang yang mencakup relai, relai kontrol mini, blok kontak bantu, modul penekan koil, dan aksesori. [Spesifikasi] 1. pole contact composition : 2 NO + 2 NC 2. mounting location : Front 3. [Ui] rated insulation voltage : -690 V - for control circuit conforming to BS 5424 -690 V - for control circuit conforming to IEC 60947 -750 V - for control circuit conforming to VDE 0010 group C -600 V - for control circuit conforming to CSA C22.2 4. [Ue] rated operational voltage : <= 690 V AC <= 400 Hz 5. [Ith] conventional free air thermal current : 10 A (at 50 °C) 6. Irms rated making capacity : 110 A at <= 690 V AC conforming to IEC 60947 7. permissible short-time rating : -80 A 1 s -60 A 500 ms -110 A 100 ms 8. associated fuse rating : -10 A gG at <= 690 V conforming to IEC 60947 -10 A gG at <= 690 V conforming to VDE 0660 9. minimum switching current : 5 mA 10. minimum switching voltage : 17 V 11. non overlap distance : 0.5 mm 12. insulation resistance : > 10 MOhm for control circuit 13. tightening torque : 1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2 14. depth : 35 mm 15. net weight : 0.045 kg
range | TeSys | |
---|---|---|
product name | TeSys K | |
product or component type | Auxiliary contact block | |
device short name | LA1 | |
range compatibility | TeSys K LC1K TeSys K CA2K TeSys K CA3K | |
mounting location | Front | |
pole contact composition | 2 NO + 2 NC | |
Contacts operation | Instantaneous | |
[Ue] rated operational voltage | 690 V AC 25...400 Hz | |
[Ie] rated operational current | 6 A at 120 V AC-15 1.04 A at 690 V AC-15 0.55 A at 125 V DC-13 0.1 A at 600 V DC-13 | |
[Ui] rated insulation voltage | 690 V conforming to IEC 60947-5-1 600 V conforming to UL 60947-5-1 600 V conforming to CSA C22.2 No 60947-5-1 | |
[Ith] conventional free air thermal current | 10 A (at 50 °C) | |
standards | EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 | |
product certifications | IECEE CB Scheme UL CSA CCC |
Irms rated making capacity | 110 A at <= 690 V AC conforming to IEC 60947 | |
---|---|---|
permissible short-time rating | 80 A 1 s 60 A 500 ms 110 A 100 ms | |
associated fuse rating | 10 A gG at <= 690 V conforming to IEC 60947 | |
minimum switching current | 5 mA | |
minimum switching voltage | 17 V | |
non overlap distance | 0.5 mm | |
insulation resistance | > 10 MOhm | |
connections - terminals | Screw clamp terminals 1 cable(s) 0.34…1.5 mm²flexible with cable end Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end Screw clamp terminals 1 cable(s) 1.5…4 mm²rigid Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end Screw clamp terminals 2 cable(s) 1.5…4 mm²rigid | |
tightening torque | 1.3 N.m - with screwdriver Philips No 2 | |
height | 30 mm | |
width | 38 mm | |
depth | 35 mm | |
net weight | 0.045 kg |
environmental characteristic | Normal environment | |
---|---|---|
IP degree of protection | IP20 conforming to IEC 60529 | |
protective treatment | TC conforming to IEC 60068 | |
ambient air temperature for storage | -50…80 °C | |
ambient air temperature for operation | -25…50 °C | |
operating altitude | 2000 m |
Unit Type of Package 1 | PCE | |
---|---|---|
Number of Units in Package 1 | 1 | |
Package 1 Weight | 30 g | |
Package 1 Height | 3.295 cm | |
Package 1 width | 3.823 cm | |
Package 1 Length | 3.917 cm |
REACh Regulation | ||
---|---|---|
REACh free of SVHC | Yes | |
EU RoHS Directive | Compliant EU RoHS Declaration | |
Toxic heavy metal free | Yes | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | China RoHS declaration Pro-active China RoHS declaration (out of China RoHS legal scope) | |
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |