Schneider EasyPact TVS contactor 3P(3 NO) - AC-3 - <= 440 V 95A - 220 V AC coil
# of Pole : 3
Rp 1,587,815.00
44.00 %
Rp 2,835,384.00
Rp 2,835,384.00
Option not available
[Deskripsi] Kontaktor yang mencapai 630A untuk pengaplikasian AC3 335kW/ 400V dan 1000A utk AC1. Kontaktor Easypact TVS 3pole dari 6A hingga 630A untuk pengaplikasian motor induktif dan kontaktor 4pole dari 16A hingga 125A untuk pengaplikasian AC1. [Spesifikasi] 1. product name : EasyPact TVS 2. product or component type : Contactor 3. device short name : LC1E 4. contactor application : -Motor control -Resistive load 5. utilisation category : -AC-1 -AC-3 6. poles description : 3P 7. power pole contact composition : 3 NO 8. [Ue] rated operational voltage : Power circuit: <= 690 V AC 50/60 Hz 9. [Ie] rated operational current : -95 A (at <60 °C) at <= 440 V AC AC-3 for power circuit -125 A (at <60 °C) at <= 440 V AC AC-1 for power circuit 10. motor power kW : -45 kW at 415 V -45 kW at 440 V -45 kW at 500 V -25 kW at 220...230 V AC 50/60 Hz -45 kW at 380...400 V -55 kW at 660...690 V 11. control circuit type : AC at 50/60 Hz 12. [Uc] control circuit voltage : 220 V AC 50/60 Hz 13. height : 127 mm 14. width : 85 mm 15. depth : 121 mm 16. net weight : 1.52 kg 17. colour : Grey (RAL 7011) 18. 1 NO + 1 NC 19. [Uimp] rated impulse withstand voltage : 6 kV coil not connected to the power circuit conforming to IEC 60947 20. [Ui] rated insulation voltage : 690 V conforming to IEC 60947-4-1 21. overvoltage category : III 22. Irms rated making capacity : 950 A at 440 V AC for power circuit conforming to IEC 60947-4-1 23. rated breaking capacity : 760 A at 440 V for power circuit conforming to IEC 60947 24. [Icw] rated short-time withstand current : -135 A 40 °C - 10 s for power circuit -800 A 40 °C - 60 s for power circuit -400 A 40 °C - 600 s for power circuit 25. associated fuse rating : -10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1 -160 A gG at <= 690 V coordination type 1 for power circuit 26. average impedance : 0.8 mOhm - Ith 110 A 50 Hz for power circuit 27. power dissipation per pole : -7.2 W AC-3 -1.2 W AC-1 28. control circuit voltage limits : -Operational: 0.85...1.1 Uc at 50 Hz (at <55 °C) -Drop-out: 0.3...0.6 Uc at 50 Hz (at <55 °C) 29. operating time : -20...26 ms on closing -8...12 ms on opening 30. mechanical durability : -5000000 cycles 31. maximum operating rate : 1200 cyc/h 55 °C 32. inrush power in VA : -160 VA 50 Hz cos phi 0.75 (at 20 °C) -140 VA 60 Hz cos phi 0.75 (at 20 °C) 33. hold-in power consumption in VA : -15 VA 50 Hz cos phi 0.3 (at 20 °C) -13 VA 60 Hz cos phi 0.3 (at 20 °C) 34. heat dissipation : 6…10 W for control circuit 35. minimum switching current : 5 mA for control circuit 36. minimum switching voltage : 17 V for control circuit 37. non-overlap time : -1.5 ms on energisation guaranteed between NC and NO contact -1.5 ms on de-energisation guaranteed between NC and NO contact 38. insulation resistance : > 10 MOhm for control circuit 39. electrical durability : -350000 cycles AC-1 -900000 cycles AC-3 40. mounting support : -Plate -DIN rail 41. standards : -IEC 60947-1 -IEC 60947-4-1 -IEC 60947-5-1 42. product certifications : EAC 43. IP degree of protection : IP2x conforming to IEC 60529 44. protective treatment : TH (pollution degree 3) conforming to IEC 60068 45. pollution degree : 3 46. ambient air temperature for operation : -5…55 °C 47. ambient air temperature for storage : -60…80 °C 48. permissible ambient air temperature around the device : -20…70 °C at Uc 49. operating altitude : 3000 m without 50. fire resistance : 850 °C conforming to IEC 60695-2-1 51. mechanical robustness : -Vibrations contactor open: 1.5 Gn, 5...300 Hz -Vibrations contactor closed: 3 Gn, 5...300 Hz -Shocks contactor open: 6 Gn for 11 ms -Shocks contactor closed: 7 Gn for 11 ms
range | EasyPact | |
---|---|---|
product name | EasyPact TVS | |
product or component type | Contactor | |
device short name | LC1E | |
contactor application | Motor control Resistive load | |
utilisation category | AC-3 AC-1 | |
poles description | 3P | |
power pole contact composition | 3 NO | |
[Ue] rated operational voltage | Power circuit: <= 690 V AC 50/60 Hz | |
[Ie] rated operational current | 95 A (at <60 °C) at <= 440 V AC AC-3 for power circuit 125 A (at <60 °C) at <= 440 V AC AC-1 for power circuit | |
motor power kW | 45 kW at 415 V 45 kW at 440 V 45 kW at 500 V 25 kW at 220...230 V AC 50/60 Hz 45 kW at 380...400 V 55 kW at 660...690 V | |
control circuit type | AC at 50/60 Hz | |
[Uc] control circuit voltage | 220 V AC 50/60 Hz | |
height | 127 mm | |
width | 85 mm | |
depth | 121 mm | |
net weight | 1.52 kg | |
colour | Grey (RAL 7011) |
auxiliary contact composition | 1 NO + 1 NC | |
---|---|---|
[Uimp] rated impulse withstand voltage | 6 kV coil not connected to the power circuit conforming to IEC 60947 | |
[Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 | |
overvoltage category | III | |
Irms rated making capacity | 950 A at 440 V AC for power circuit conforming to IEC 60947-4-1 | |
rated breaking capacity | 760 A at 440 V for power circuit conforming to IEC 60947 | |
[Icw] rated short-time withstand current | 135 A 40 °C - 600 s for power circuit 800 A 40 °C - 10 s for power circuit 400 A 40 °C - 60 s for power circuit | |
associated fuse rating | 10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1 160 A gG at <= 690 V coordination type 1 for power circuit | |
average impedance | 0.8 mOhm - Ith 120 A 50 Hz for power circuit | |
power dissipation per pole | 7.2 W AC-3 12 W AC-1 | |
control circuit voltage limits | Operational: 0.85...1.1 Uc at 50/60 Hz (at <55 °C) Drop-out: 0.3...0.6 Uc at 50/60 Hz (at <55 °C) | |
operating time | 20...35 ms on closing 6...30 ms on opening | |
mechanical durability | 300000 cycles | |
maximum operating rate | 1200 cyc/h 60 °C | |
inrush power in VA | 200 VA 50 Hz cos phi 0.75 (at 20 °C) 220 VA 60 Hz cos phi 0.75 (at 20 °C) | |
hold-in power consumption in VA | 22 VA 60 Hz cos phi 0.3 (at 20 °C) 20 VA 50 Hz cos phi 0.3 (at 20 °C) | |
heat dissipation | 6…10 W for control circuit | |
minimum switching current | 5 mA for control circuit | |
minimum switching voltage | 17 V for control circuit | |
non-overlap time | 1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact | |
insulation resistance | > 10 MOhm for control circuit | |
electrical durability | 350000 cycles AC-3 900000 cycles AC-1 | |
mounting support | Plate DIN rail | |
connections - terminals | Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 1 4…50 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 4…16 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 4…50 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 2 4…50 mm² - cable stiffness: solid without cable end | |
Recommended tightening torque | Control circuit: 1.2 N.m Power circuit: 12 N.m | |
Max tightening torque | Control circuit: 1.4 N.m Power circuit: 13.5 N.m |
standards | IEC 60947-5-1 IEC 60947-4-1 IEC 60947-1 | |
---|---|---|
product certifications | EAC CE | |
IP degree of protection | IP2x conforming to IEC 60529 | |
protective treatment | TH (pollution degree 3) conforming to IEC 60068-2-30 test Db | |
pollution degree | 3 | |
ambient air temperature for operation | -5…55 °C | |
ambient air temperature for storage | -60…80 °C | |
permissible ambient air temperature around the device | -20…70 °C at Uc | |
operating altitude | 3000 m without derating | |
fire resistance | 850 °C conforming to IEC 60695-2-1 | |
mechanical robustness | Vibrations contactor open: 1.5 Gn, 5...300 Hz Vibrations contactor closed: 3 Gn, 5...300 Hz Shocks contactor open: 6 Gn for 11 ms Shocks contactor closed: 7 Gn for 11 ms |
Package 1 Weight | 1.400 g | |
---|---|---|
Package 1 Height | 121.000 mm | |
Package 1 width | 85.000 mm | |
Package 1 Length | 127.000 mm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
EU RoHS Directive | Compliant EU RoHS Declaration | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | China RoHS declaration Product out of China RoHS scope. Substance declaration for your information | |
Environmental Disclosure | ||
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Warranty | 12 months |
---|
Specifications for Schneider EasyPact TVS contactor 3P(3 NO) - AC-3 - <= 440 V 95A - 220 V AC coil
# of Pole | 3 |
Filter By
[Deskripsi] Kontaktor yang mencapai 630A untuk pengaplikasian AC3 335kW/ 400V dan 1000A utk AC1. Kontaktor Easypact TVS 3pole dari 6A hingga 630A untuk pengaplikasian motor induktif dan kontaktor 4pole dari 16A hingga 125A untuk pengaplikasian AC1. [Spesifikasi] 1. product name : EasyPact TVS 2. product or component type : Contactor 3. device short name : LC1E 4. contactor application : -Motor control -Resistive load 5. utilisation category : -AC-1 -AC-3 6. poles description : 3P 7. power pole contact composition : 3 NO 8. [Ue] rated operational voltage : Power circuit: <= 690 V AC 50/60 Hz 9. [Ie] rated operational current : -95 A (at <60 °C) at <= 440 V AC AC-3 for power circuit -125 A (at <60 °C) at <= 440 V AC AC-1 for power circuit 10. motor power kW : -45 kW at 415 V -45 kW at 440 V -45 kW at 500 V -25 kW at 220...230 V AC 50/60 Hz -45 kW at 380...400 V -55 kW at 660...690 V 11. control circuit type : AC at 50/60 Hz 12. [Uc] control circuit voltage : 220 V AC 50/60 Hz 13. height : 127 mm 14. width : 85 mm 15. depth : 121 mm 16. net weight : 1.52 kg 17. colour : Grey (RAL 7011) 18. 1 NO + 1 NC 19. [Uimp] rated impulse withstand voltage : 6 kV coil not connected to the power circuit conforming to IEC 60947 20. [Ui] rated insulation voltage : 690 V conforming to IEC 60947-4-1 21. overvoltage category : III 22. Irms rated making capacity : 950 A at 440 V AC for power circuit conforming to IEC 60947-4-1 23. rated breaking capacity : 760 A at 440 V for power circuit conforming to IEC 60947 24. [Icw] rated short-time withstand current : -135 A 40 °C - 10 s for power circuit -800 A 40 °C - 60 s for power circuit -400 A 40 °C - 600 s for power circuit 25. associated fuse rating : -10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1 -160 A gG at <= 690 V coordination type 1 for power circuit 26. average impedance : 0.8 mOhm - Ith 110 A 50 Hz for power circuit 27. power dissipation per pole : -7.2 W AC-3 -1.2 W AC-1 28. control circuit voltage limits : -Operational: 0.85...1.1 Uc at 50 Hz (at <55 °C) -Drop-out: 0.3...0.6 Uc at 50 Hz (at <55 °C) 29. operating time : -20...26 ms on closing -8...12 ms on opening 30. mechanical durability : -5000000 cycles 31. maximum operating rate : 1200 cyc/h 55 °C 32. inrush power in VA : -160 VA 50 Hz cos phi 0.75 (at 20 °C) -140 VA 60 Hz cos phi 0.75 (at 20 °C) 33. hold-in power consumption in VA : -15 VA 50 Hz cos phi 0.3 (at 20 °C) -13 VA 60 Hz cos phi 0.3 (at 20 °C) 34. heat dissipation : 6…10 W for control circuit 35. minimum switching current : 5 mA for control circuit 36. minimum switching voltage : 17 V for control circuit 37. non-overlap time : -1.5 ms on energisation guaranteed between NC and NO contact -1.5 ms on de-energisation guaranteed between NC and NO contact 38. insulation resistance : > 10 MOhm for control circuit 39. electrical durability : -350000 cycles AC-1 -900000 cycles AC-3 40. mounting support : -Plate -DIN rail 41. standards : -IEC 60947-1 -IEC 60947-4-1 -IEC 60947-5-1 42. product certifications : EAC 43. IP degree of protection : IP2x conforming to IEC 60529 44. protective treatment : TH (pollution degree 3) conforming to IEC 60068 45. pollution degree : 3 46. ambient air temperature for operation : -5…55 °C 47. ambient air temperature for storage : -60…80 °C 48. permissible ambient air temperature around the device : -20…70 °C at Uc 49. operating altitude : 3000 m without 50. fire resistance : 850 °C conforming to IEC 60695-2-1 51. mechanical robustness : -Vibrations contactor open: 1.5 Gn, 5...300 Hz -Vibrations contactor closed: 3 Gn, 5...300 Hz -Shocks contactor open: 6 Gn for 11 ms -Shocks contactor closed: 7 Gn for 11 ms
range | EasyPact | |
---|---|---|
product name | EasyPact TVS | |
product or component type | Contactor | |
device short name | LC1E | |
contactor application | Motor control Resistive load | |
utilisation category | AC-3 AC-1 | |
poles description | 3P | |
power pole contact composition | 3 NO | |
[Ue] rated operational voltage | Power circuit: <= 690 V AC 50/60 Hz | |
[Ie] rated operational current | 95 A (at <60 °C) at <= 440 V AC AC-3 for power circuit 125 A (at <60 °C) at <= 440 V AC AC-1 for power circuit | |
motor power kW | 45 kW at 415 V 45 kW at 440 V 45 kW at 500 V 25 kW at 220...230 V AC 50/60 Hz 45 kW at 380...400 V 55 kW at 660...690 V | |
control circuit type | AC at 50/60 Hz | |
[Uc] control circuit voltage | 220 V AC 50/60 Hz | |
height | 127 mm | |
width | 85 mm | |
depth | 121 mm | |
net weight | 1.52 kg | |
colour | Grey (RAL 7011) |
auxiliary contact composition | 1 NO + 1 NC | |
---|---|---|
[Uimp] rated impulse withstand voltage | 6 kV coil not connected to the power circuit conforming to IEC 60947 | |
[Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 | |
overvoltage category | III | |
Irms rated making capacity | 950 A at 440 V AC for power circuit conforming to IEC 60947-4-1 | |
rated breaking capacity | 760 A at 440 V for power circuit conforming to IEC 60947 | |
[Icw] rated short-time withstand current | 135 A 40 °C - 600 s for power circuit 800 A 40 °C - 10 s for power circuit 400 A 40 °C - 60 s for power circuit | |
associated fuse rating | 10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1 160 A gG at <= 690 V coordination type 1 for power circuit | |
average impedance | 0.8 mOhm - Ith 120 A 50 Hz for power circuit | |
power dissipation per pole | 7.2 W AC-3 12 W AC-1 | |
control circuit voltage limits | Operational: 0.85...1.1 Uc at 50/60 Hz (at <55 °C) Drop-out: 0.3...0.6 Uc at 50/60 Hz (at <55 °C) | |
operating time | 20...35 ms on closing 6...30 ms on opening | |
mechanical durability | 300000 cycles | |
maximum operating rate | 1200 cyc/h 60 °C | |
inrush power in VA | 200 VA 50 Hz cos phi 0.75 (at 20 °C) 220 VA 60 Hz cos phi 0.75 (at 20 °C) | |
hold-in power consumption in VA | 22 VA 60 Hz cos phi 0.3 (at 20 °C) 20 VA 50 Hz cos phi 0.3 (at 20 °C) | |
heat dissipation | 6…10 W for control circuit | |
minimum switching current | 5 mA for control circuit | |
minimum switching voltage | 17 V for control circuit | |
non-overlap time | 1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact | |
insulation resistance | > 10 MOhm for control circuit | |
electrical durability | 350000 cycles AC-3 900000 cycles AC-1 | |
mounting support | Plate DIN rail | |
connections - terminals | Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 1 4…50 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 4…16 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 4…50 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 2 4…50 mm² - cable stiffness: solid without cable end | |
Recommended tightening torque | Control circuit: 1.2 N.m Power circuit: 12 N.m | |
Max tightening torque | Control circuit: 1.4 N.m Power circuit: 13.5 N.m |
standards | IEC 60947-5-1 IEC 60947-4-1 IEC 60947-1 | |
---|---|---|
product certifications | EAC CE | |
IP degree of protection | IP2x conforming to IEC 60529 | |
protective treatment | TH (pollution degree 3) conforming to IEC 60068-2-30 test Db | |
pollution degree | 3 | |
ambient air temperature for operation | -5…55 °C | |
ambient air temperature for storage | -60…80 °C | |
permissible ambient air temperature around the device | -20…70 °C at Uc | |
operating altitude | 3000 m without derating | |
fire resistance | 850 °C conforming to IEC 60695-2-1 | |
mechanical robustness | Vibrations contactor open: 1.5 Gn, 5...300 Hz Vibrations contactor closed: 3 Gn, 5...300 Hz Shocks contactor open: 6 Gn for 11 ms Shocks contactor closed: 7 Gn for 11 ms |
Package 1 Weight | 1.400 g | |
---|---|---|
Package 1 Height | 121.000 mm | |
Package 1 width | 85.000 mm | |
Package 1 Length | 127.000 mm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
EU RoHS Directive | Compliant EU RoHS Declaration | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | China RoHS declaration Product out of China RoHS scope. Substance declaration for your information | |
Environmental Disclosure | ||
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Warranty | 12 months |
---|