Schneider EasyPact TVS contactor 3P(3 NO) - AC-3 - <= 440 V 25A - 220 V AC coil
# of Pole : 3
Rp 312,440.00
44.00 %
Rp 557,930.00
Rp 557,930.00
Option not available
[Deskripsi] 1. product name : EasyPact TVS 2. product or component type : Contactor 3. device short name : LC1E 4. contactor application : -Resistive load -Motor control 5. utilisation category : -AC-1 -AC-3 6. poles description : 3P 7. power pole contact composition : 3 NO 8. [Ue] rated operational voltage : Power circuit: <= 690 V AC 50/60 Hz 9. [Ie] rated operational current : -25 A (at <60 °C) at <= 440 V AC AC-3 for power circuit -36 A (at <60 °C) at <= 440 V AC AC-1 for power circuit 10. motor power kW : -5.5 kW at 220...230 V AC 50/60 Hz -11 kW at 380...400 V -11 kW at 415 V -11 kW at 440 V -15 kW at 500 V -15 kW at 660...690 V 11. control circuit type : AC at 50/60 Hz 12. [Uc] control circuit voltage : 220 V AC 50/60 Hz 13. height : 74 mm 14. width : 45 mm 15. depth : 80 mm 16. product weight : 0.36 kg 27. colour : Grey (RAL 7011) 28. auxiliary contact composition : 1 NC 29. [Uimp] rated impulse withstand voltage : 6 kV coil not connected to the power circuit conforming to IEC 60947 30. [Ui] rated insulation voltage : 690 V conforming to IEC 60947-4-1 31. overvoltage category : III 32. Irms rated making capacity : 250 A at 440 V AC for power circuit conforming to IEC 60947-4-1 33. rated breaking capacity : 200 A at 440 V for power circuit conforming to IEC 60947 34. [Icw] rated short-time withstand current : -240 A 40 °C - 10 s for power circuit -120 A 40 °C - 60 s for power circuit -50 A 40 °C - 600 s for power circuit 35. associated fuse rating : -10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1 -40 A gG at <= 690 V coordination type 1 for power circuit 36. average impedance : 2.5 mOhm - Ith 20 A 50 Hz for power circuit 37. power dissipation per pole : -2.5 W AC-3 -1.6 W AC-1 38. control circuit voltage limits : -Operational: 0.85...1.1 Uc at 50 Hz (at <55 °C) -Drop-out: 0.3...0.6 Uc at 50 Hz (at <55 °C) 39. operating time : -12...22 ms on closing -4...19 ms on opening 40. mechanical durability : 10000000 cycles 41. maximum operating rate : 1800 cyc/h 60 °C 42. inrush power in VA : -95 VA 50 Hz cos phi 0.75 (at 20 °C) -95 VA 60 Hz cos phi 0.75 (at 20 °C) 43. hold-in power consumption in VA : -8.5 VA 50 Hz cos phi 0.3 (at 20 °C) -8.5 VA 60 Hz cos phi 0.3 (at 20 °C) 44. heat dissipation : 2…3 W for control circuit 45. minimum switching current : 5 mA for control circuit 46. minimum switching voltage : 17 V for control circuit 47. non-overlap time : -1.5 ms on energisation guaranteed between NC and NO contact -1.5 ms on de-energisation guaranteed between NC and NO contact 48. insulation resistance : > 10 MOhm for control circuit 49. electrical durability : -1400000 cycles AC-3 -150000 cycles AC-1 50. mounting support : -DIN rail -Plate 51. standards : -IEC 60947-5-1 -IEC 60947-1 -IEC 60947-4-1 52. product certifications : EAC 53. IP degree of protection : IP2x conforming to IEC 60529 54. protective treatment : TH (pollution degree 3) conforming to IEC 60068 55. pollution degree : 3 56. ambient air temperature for operation : -5…55 °C 57. ambient air temperature for storage : -60…80 °C 58. permissible ambient air temperature around the device : -20…70 °C at Uc 59. operating altitude : 3000 m without 60. fire resistance : 850 °C conforming to IEC 60695-2-1 61. mechanical robustness : -Vibrations contactor open: 1.5 Gn, 5...300 Hz -Vibrations contactor closed: 3 Gn, 5...300 Hz -Shocks contactor open: 7 Gn for 11 ms -Shocks contactor closed: 10 Gn for 11 ms
range | EasyPact | |
---|---|---|
product name | EasyPact TVS | |
product or component type | Contactor | |
device short name | LC1E | |
contactor application | Motor control Resistive load | |
utilisation category | AC-3 AC-1 | |
poles description | 3P | |
power pole contact composition | 3 NO | |
[Ue] rated operational voltage | Power circuit: <= 690 V AC 50/60 Hz | |
[Ie] rated operational current | 25 A (at <60 °C) at <= 440 V AC AC-3 for power circuit 36 A (at <60 °C) at <= 440 V AC AC-1 for power circuit | |
motor power kW | 5.5 kW at 220...230 V AC 50/60 Hz 11 kW at 380...400 V 11 kW at 415 V 11 kW at 440 V 15 kW at 500 V 15 kW at 660...690 V | |
control circuit type | AC at 50/60 Hz | |
[Uc] control circuit voltage | 220 V AC 50/60 Hz | |
height | 74 mm | |
width | 45 mm | |
depth | 85 mm | |
net weight | 0.36 kg | |
colour | Grey (RAL 7011) |
auxiliary contact composition | 1 NC | |
---|---|---|
[Uimp] rated impulse withstand voltage | 6 kV coil not connected to the power circuit conforming to IEC 60947 | |
[Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 | |
overvoltage category | III | |
Irms rated making capacity | 250 A at 440 V AC for power circuit conforming to IEC 60947-4-1 | |
rated breaking capacity | 200 A at 440 V for power circuit conforming to IEC 60947 | |
[Icw] rated short-time withstand current | 240 A 40 °C - 10 s for power circuit 120 A 40 °C - 60 s for power circuit 50 A 40 °C - 600 s for power circuit | |
associated fuse rating | 10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1 40 A gG at <= 690 V coordination type 1 for power circuit | |
average impedance | 2.5 mOhm - Ith 36 A 50 Hz for power circuit | |
power dissipation per pole | 1.6 W AC-1 2.5 W AC-3 | |
control circuit voltage limits | Operational: 0.85...1.1 Uc at 50/60 Hz (at <55 °C) Drop-out: 0.3...0.6 Uc at 50/60 Hz (at <55 °C) | |
operating time | 12...22 ms on closing 4...19 ms on opening | |
mechanical durability | 1000000 cycles | |
maximum operating rate | 1800 cyc/h 60 °C | |
inrush power in VA | 95 VA 50 Hz cos phi 0.75 (at 20 °C) 95 VA 60 Hz cos phi 0.75 (at 20 °C) | |
hold-in power consumption in VA | 8.3 VA 50 Hz cos phi 0.3 (at 20 °C) 8.5 VA 60 Hz cos phi 0.3 (at 20 °C) | |
heat dissipation | 2…3 W for control circuit | |
minimum switching current | 5 mA for control circuit | |
minimum switching voltage | 17 V for control circuit | |
non-overlap time | 1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact | |
insulation resistance | > 10 MOhm for control circuit | |
electrical durability | 1200000 cycles AC-3 350000 cycles AC-1 | |
mounting support | DIN rail Plate | |
connections - terminals | Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 1 1.5…6 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 2 1.5…6 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 1 1…6 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible with cable end | |
Recommended tightening torque | Control circuit: 1.2 N.m Power circuit: 1.5 N.m | |
Max tightening torque | Control circuit: 1.4 N.m Power circuit: 1.7 N.m |
standards | IEC 60947-1 IEC 60947-4-1 IEC 60947-5-1 | |
---|---|---|
product certifications | EAC CE | |
IP degree of protection | IP2x conforming to IEC 60529 | |
protective treatment | TH (pollution degree 3) conforming to IEC 60068-2-30 test Db | |
pollution degree | 3 | |
ambient air temperature for operation | -5…55 °C | |
ambient air temperature for storage | -60…80 °C | |
permissible ambient air temperature around the device | -20…70 °C at Uc | |
operating altitude | 3000 m without derating | |
fire resistance | 850 °C conforming to IEC 60695-2-1 | |
mechanical robustness | Vibrations contactor open: 1.5 Gn, 5...300 Hz Vibrations contactor closed: 3 Gn, 5...300 Hz Shocks contactor closed: 10 Gn for 11 ms Shocks contactor open: 6 Gn for 11 ms |
Package 1 Weight | 340.000 g | |
---|---|---|
Package 1 Height | 85.000 mm | |
Package 1 width | 45.000 mm | |
Package 1 Length | 74.000 mm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
REACh free of SVHC | Yes | |
EU RoHS Directive | Compliant EU RoHS Declaration | |
Toxic heavy metal free | Yes | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | ||
Environmental Disclosure | ||
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Specifications for Schneider EasyPact TVS contactor 3P(3 NO) - AC-3 - <= 440 V 25A - 220 V AC coil
# of Pole | 3 |
[Deskripsi] 1. product name : EasyPact TVS 2. product or component type : Contactor 3. device short name : LC1E 4. contactor application : -Resistive load -Motor control 5. utilisation category : -AC-1 -AC-3 6. poles description : 3P 7. power pole contact composition : 3 NO 8. [Ue] rated operational voltage : Power circuit: <= 690 V AC 50/60 Hz 9. [Ie] rated operational current : -25 A (at <60 °C) at <= 440 V AC AC-3 for power circuit -36 A (at <60 °C) at <= 440 V AC AC-1 for power circuit 10. motor power kW : -5.5 kW at 220...230 V AC 50/60 Hz -11 kW at 380...400 V -11 kW at 415 V -11 kW at 440 V -15 kW at 500 V -15 kW at 660...690 V 11. control circuit type : AC at 50/60 Hz 12. [Uc] control circuit voltage : 220 V AC 50/60 Hz 13. height : 74 mm 14. width : 45 mm 15. depth : 80 mm 16. product weight : 0.36 kg 27. colour : Grey (RAL 7011) 28. auxiliary contact composition : 1 NC 29. [Uimp] rated impulse withstand voltage : 6 kV coil not connected to the power circuit conforming to IEC 60947 30. [Ui] rated insulation voltage : 690 V conforming to IEC 60947-4-1 31. overvoltage category : III 32. Irms rated making capacity : 250 A at 440 V AC for power circuit conforming to IEC 60947-4-1 33. rated breaking capacity : 200 A at 440 V for power circuit conforming to IEC 60947 34. [Icw] rated short-time withstand current : -240 A 40 °C - 10 s for power circuit -120 A 40 °C - 60 s for power circuit -50 A 40 °C - 600 s for power circuit 35. associated fuse rating : -10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1 -40 A gG at <= 690 V coordination type 1 for power circuit 36. average impedance : 2.5 mOhm - Ith 20 A 50 Hz for power circuit 37. power dissipation per pole : -2.5 W AC-3 -1.6 W AC-1 38. control circuit voltage limits : -Operational: 0.85...1.1 Uc at 50 Hz (at <55 °C) -Drop-out: 0.3...0.6 Uc at 50 Hz (at <55 °C) 39. operating time : -12...22 ms on closing -4...19 ms on opening 40. mechanical durability : 10000000 cycles 41. maximum operating rate : 1800 cyc/h 60 °C 42. inrush power in VA : -95 VA 50 Hz cos phi 0.75 (at 20 °C) -95 VA 60 Hz cos phi 0.75 (at 20 °C) 43. hold-in power consumption in VA : -8.5 VA 50 Hz cos phi 0.3 (at 20 °C) -8.5 VA 60 Hz cos phi 0.3 (at 20 °C) 44. heat dissipation : 2…3 W for control circuit 45. minimum switching current : 5 mA for control circuit 46. minimum switching voltage : 17 V for control circuit 47. non-overlap time : -1.5 ms on energisation guaranteed between NC and NO contact -1.5 ms on de-energisation guaranteed between NC and NO contact 48. insulation resistance : > 10 MOhm for control circuit 49. electrical durability : -1400000 cycles AC-3 -150000 cycles AC-1 50. mounting support : -DIN rail -Plate 51. standards : -IEC 60947-5-1 -IEC 60947-1 -IEC 60947-4-1 52. product certifications : EAC 53. IP degree of protection : IP2x conforming to IEC 60529 54. protective treatment : TH (pollution degree 3) conforming to IEC 60068 55. pollution degree : 3 56. ambient air temperature for operation : -5…55 °C 57. ambient air temperature for storage : -60…80 °C 58. permissible ambient air temperature around the device : -20…70 °C at Uc 59. operating altitude : 3000 m without 60. fire resistance : 850 °C conforming to IEC 60695-2-1 61. mechanical robustness : -Vibrations contactor open: 1.5 Gn, 5...300 Hz -Vibrations contactor closed: 3 Gn, 5...300 Hz -Shocks contactor open: 7 Gn for 11 ms -Shocks contactor closed: 10 Gn for 11 ms
range | EasyPact | |
---|---|---|
product name | EasyPact TVS | |
product or component type | Contactor | |
device short name | LC1E | |
contactor application | Motor control Resistive load | |
utilisation category | AC-3 AC-1 | |
poles description | 3P | |
power pole contact composition | 3 NO | |
[Ue] rated operational voltage | Power circuit: <= 690 V AC 50/60 Hz | |
[Ie] rated operational current | 25 A (at <60 °C) at <= 440 V AC AC-3 for power circuit 36 A (at <60 °C) at <= 440 V AC AC-1 for power circuit | |
motor power kW | 5.5 kW at 220...230 V AC 50/60 Hz 11 kW at 380...400 V 11 kW at 415 V 11 kW at 440 V 15 kW at 500 V 15 kW at 660...690 V | |
control circuit type | AC at 50/60 Hz | |
[Uc] control circuit voltage | 220 V AC 50/60 Hz | |
height | 74 mm | |
width | 45 mm | |
depth | 85 mm | |
net weight | 0.36 kg | |
colour | Grey (RAL 7011) |
auxiliary contact composition | 1 NC | |
---|---|---|
[Uimp] rated impulse withstand voltage | 6 kV coil not connected to the power circuit conforming to IEC 60947 | |
[Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 | |
overvoltage category | III | |
Irms rated making capacity | 250 A at 440 V AC for power circuit conforming to IEC 60947-4-1 | |
rated breaking capacity | 200 A at 440 V for power circuit conforming to IEC 60947 | |
[Icw] rated short-time withstand current | 240 A 40 °C - 10 s for power circuit 120 A 40 °C - 60 s for power circuit 50 A 40 °C - 600 s for power circuit | |
associated fuse rating | 10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1 40 A gG at <= 690 V coordination type 1 for power circuit | |
average impedance | 2.5 mOhm - Ith 36 A 50 Hz for power circuit | |
power dissipation per pole | 1.6 W AC-1 2.5 W AC-3 | |
control circuit voltage limits | Operational: 0.85...1.1 Uc at 50/60 Hz (at <55 °C) Drop-out: 0.3...0.6 Uc at 50/60 Hz (at <55 °C) | |
operating time | 12...22 ms on closing 4...19 ms on opening | |
mechanical durability | 1000000 cycles | |
maximum operating rate | 1800 cyc/h 60 °C | |
inrush power in VA | 95 VA 50 Hz cos phi 0.75 (at 20 °C) 95 VA 60 Hz cos phi 0.75 (at 20 °C) | |
hold-in power consumption in VA | 8.3 VA 50 Hz cos phi 0.3 (at 20 °C) 8.5 VA 60 Hz cos phi 0.3 (at 20 °C) | |
heat dissipation | 2…3 W for control circuit | |
minimum switching current | 5 mA for control circuit | |
minimum switching voltage | 17 V for control circuit | |
non-overlap time | 1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact | |
insulation resistance | > 10 MOhm for control circuit | |
electrical durability | 1200000 cycles AC-3 350000 cycles AC-1 | |
mounting support | DIN rail Plate | |
connections - terminals | Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 1 1.5…6 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 2 1.5…6 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 1 1…6 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible with cable end | |
Recommended tightening torque | Control circuit: 1.2 N.m Power circuit: 1.5 N.m | |
Max tightening torque | Control circuit: 1.4 N.m Power circuit: 1.7 N.m |
standards | IEC 60947-1 IEC 60947-4-1 IEC 60947-5-1 | |
---|---|---|
product certifications | EAC CE | |
IP degree of protection | IP2x conforming to IEC 60529 | |
protective treatment | TH (pollution degree 3) conforming to IEC 60068-2-30 test Db | |
pollution degree | 3 | |
ambient air temperature for operation | -5…55 °C | |
ambient air temperature for storage | -60…80 °C | |
permissible ambient air temperature around the device | -20…70 °C at Uc | |
operating altitude | 3000 m without derating | |
fire resistance | 850 °C conforming to IEC 60695-2-1 | |
mechanical robustness | Vibrations contactor open: 1.5 Gn, 5...300 Hz Vibrations contactor closed: 3 Gn, 5...300 Hz Shocks contactor closed: 10 Gn for 11 ms Shocks contactor open: 6 Gn for 11 ms |
Package 1 Weight | 340.000 g | |
---|---|---|
Package 1 Height | 85.000 mm | |
Package 1 width | 45.000 mm | |
Package 1 Length | 74.000 mm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
REACh free of SVHC | Yes | |
EU RoHS Directive | Compliant EU RoHS Declaration | |
Toxic heavy metal free | Yes | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | ||
Environmental Disclosure | ||
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |