Spesifikasi
| range | EasyPact | |
|---|---|---|
| product name | EasyPact TVS | |
| product or component type | Differential thermal overload relay | |
| device short name | LRE | |
| relay application | Motor protection | |
| phase failure sensitivity | Tripping current 130 % of Ir on two phase, the last one at 0 conforming to IEC 60947-4-1 | |
| colour | Grey (RAL 7011) |
| product compatibility | LC1E06...38 | |
|---|---|---|
| network type | AC | |
| network frequency | 50...60 Hz | |
| mounting support | Under contactor Plate, with specific accessories Rail, with specific accessories | |
| thermal overload class | Class 10A conforming to IEC 60947-4-1 | |
| signalling function | Relay trip indicator | |
| thermal protection adjustment range | 0.16…0.25 A | |
| tripping threshold | 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1 | |
| mechanical robustness | Shocks: 6 Gn for 11 ms conforming to IEC 60068-2-7 Vibrations: 3 Gn conforming to IEC 60068-2-6 | |
| auxiliary contact composition | 1 NO + 1 NC | |
| [Ith] conventional free air thermal current | 5 A for signalling circuit | |
| [Ue] rated operational voltage | <= 690 V AC | |
| associated fuse rating | 2 A gG for power circuit 0.5 A aM for power circuit 5 A gG for signalling circuit | |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 | |
| [Uimp] rated impulse withstand voltage | 6 kV | |
| local signalling | Trip indicator | |
| control type | Push-button red stop: Push-button green reset: | |
| temperature compensation | -20…60 °C | |
| connections - terminals | Power circuit: screw clamp terminals 1 1.5…6 mm² - cable stiffness: flexible without cable end Power circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 1…6 mm² - cable stiffness: solid without cable end Signalling circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible without cable end Signalling circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end Signalling circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: solid without cable end | |
| Recommended tightening torque | Power circuit: 1.7 N.m - on screw clamp terminals Signalling circuit: 1.7 N.m - on screw clamp terminals | |
| height | 44.5 mm | |
| width | 45 mm | |
| depth | 70 mm | |
| net weight | 0.13 kg |
| standards | IEC 60947-5-1 IEC 60947-4-1 | |
|---|---|---|
| product certifications | EAC | |
| protective treatment | TH conforming to IEC 60068 | |
| IP degree of protection | IP20 conforming to IEC 60529 | |
| ambient air temperature for operation | -20…60 °C without derating conforming to IEC 60947-4-1 -20…70 °C with derating | |
| ambient air temperature for storage | -60…80 °C | |
| fire resistance | 850 °C conforming to IEC 60068-2-1 | |
| dielectric strength | 6 kV at 50 Hz conforming to IEC 60255-5 | |
| electromagnetic compatibility | Surge withstand: 6 kV conforming to IEC 60801-5 |
| Package 1 Weight | 0.142 kg | |
|---|---|---|
| Package 1 Height | 0.550 dm | |
| Package 1 width | 0.800 dm | |
| Package 1 Length | 0.850 dm |
| REACh Regulation | ||
|---|---|---|
| REACh free of SVHC | Yes | |
| EU RoHS Directive | Compliant EU RoHS Declaration | |
| Mercury free | Yes | |
| RoHS exemption information | ||
| China RoHS Regulation | China RoHS declaration Product out of China RoHS scope. Substance declaration for your information | |
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Warranty | 12 months |
|---|
| range | EasyPact | |
|---|---|---|
| product name | EasyPact TVS | |
| product or component type | Differential thermal overload relay | |
| device short name | LRE | |
| relay application | Motor protection | |
| phase failure sensitivity | Tripping current 130 % of Ir on two phase, the last one at 0 conforming to IEC 60947-4-1 | |
| colour | Grey (RAL 7011) |
| product compatibility | LC1E06...38 | |
|---|---|---|
| network type | AC | |
| network frequency | 50...60 Hz | |
| mounting support | Under contactor Plate, with specific accessories Rail, with specific accessories | |
| thermal overload class | Class 10A conforming to IEC 60947-4-1 | |
| signalling function | Relay trip indicator | |
| thermal protection adjustment range | 0.16…0.25 A | |
| tripping threshold | 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1 | |
| mechanical robustness | Shocks: 6 Gn for 11 ms conforming to IEC 60068-2-7 Vibrations: 3 Gn conforming to IEC 60068-2-6 | |
| auxiliary contact composition | 1 NO + 1 NC | |
| [Ith] conventional free air thermal current | 5 A for signalling circuit | |
| [Ue] rated operational voltage | <= 690 V AC | |
| associated fuse rating | 2 A gG for power circuit 0.5 A aM for power circuit 5 A gG for signalling circuit | |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 | |
| [Uimp] rated impulse withstand voltage | 6 kV | |
| local signalling | Trip indicator | |
| control type | Push-button red stop: Push-button green reset: | |
| temperature compensation | -20…60 °C | |
| connections - terminals | Power circuit: screw clamp terminals 1 1.5…6 mm² - cable stiffness: flexible without cable end Power circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 1…6 mm² - cable stiffness: solid without cable end Signalling circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible without cable end Signalling circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end Signalling circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: solid without cable end | |
| Recommended tightening torque | Power circuit: 1.7 N.m - on screw clamp terminals Signalling circuit: 1.7 N.m - on screw clamp terminals | |
| height | 44.5 mm | |
| width | 45 mm | |
| depth | 70 mm | |
| net weight | 0.13 kg |
| standards | IEC 60947-5-1 IEC 60947-4-1 | |
|---|---|---|
| product certifications | EAC | |
| protective treatment | TH conforming to IEC 60068 | |
| IP degree of protection | IP20 conforming to IEC 60529 | |
| ambient air temperature for operation | -20…60 °C without derating conforming to IEC 60947-4-1 -20…70 °C with derating | |
| ambient air temperature for storage | -60…80 °C | |
| fire resistance | 850 °C conforming to IEC 60068-2-1 | |
| dielectric strength | 6 kV at 50 Hz conforming to IEC 60255-5 | |
| electromagnetic compatibility | Surge withstand: 6 kV conforming to IEC 60801-5 |
| Package 1 Weight | 0.142 kg | |
|---|---|---|
| Package 1 Height | 0.550 dm | |
| Package 1 width | 0.800 dm | |
| Package 1 Length | 0.850 dm |
| REACh Regulation | ||
|---|---|---|
| REACh free of SVHC | Yes | |
| EU RoHS Directive | Compliant EU RoHS Declaration | |
| Mercury free | Yes | |
| RoHS exemption information | ||
| China RoHS Regulation | China RoHS declaration Product out of China RoHS scope. Substance declaration for your information | |
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Warranty | 12 months |
|---|
Recently Viewed Products
Schneider EasyPact TVS differential thermal overload relay 0.16.0.25 A - class 10A
Rp 427,350.00
Rp 241,922.00
Schneider Blue complete pilot light (D)22 plain lens with integral LED 110 120V
Rp 409,645.00
Rp 240,993.00
Schneider Blue flush complete illum pushbutton (D)22 spring return 1NO+1NC 220.240V
Rp 457,264.00
Rp 269,007.00
HOT PROMO