• Sign up now and get discount up to 47%

Schneider Harmony K1/K2 - cam switch - 3 poles - 12 A - for D 22 mm

Rp 954,655.00 Rp 553,699.00 553699 IDR

Rp 954,655.00

Option not available

    This combination does not exist.

    Add to Cart

    Schneider Harmony K1/K2 - cam switch - 3 poles - 12 A - for D 22 mm
    Terjual 0
    0 (0 Rating)
    Ulasan (0)

    Rp 553,699.00
    42.00 % Rp 954,655.00 553699 IDR

    Rp 954,655.00

    Option not available

    Atur Jumlah & Catatan
    Stock Total: 2
    Spesifikasi
    Main (see above)
    range of product
    Harmony K
    product or component type
    Complete cam switch
    component name
    K1
    [Ith] conventional free air thermal current
    12 A
    fixing mode
    Ø 16 or 22 mm hole
    cam switch head type
    With front plate 45 x 45 mm
    type of operator
    Black handle, length = 35 mm
    rotary handle padlocking
    Without
    presentation of legend
    With metallic legend black marking
    cam switch function
    Switch
    return
    Without
    off position
    With Off position
    poles description
    4P
    switching positions
    Right: 0° - 45° - 90° - 135° - 180°
    IP degree of protection
    IP65 conforming to IEC 529
    IP65 conforming to NF C 20-010
    Complementary (see above)
    number of steps
    45
    [Ui] rated insulation voltage
    690 V (pollution degree 3) conforming to IEC 60947-1
    [Ithe] conventional enclosed thermal current
    10 A
    rated operational power in W
    10500 W AC-21, 500...660 V 3 phases conforming to IEC 947-3
    1100 W AC-3, 230 V 3 phases conforming to IEC 947-3
    1500 W AC-23A, 230 V 3 phases conforming to IEC 947-3
    1500 W AC-3, 400 V 1 phase conforming to IEC 947-3
    1500 W AC-3, 400 V 3 phases conforming to IEC 947-3
    1500 W AC-3, 500 V 3 phases conforming to IEC 947-3
    1500 W AC-3, 690 V 3 phases conforming to IEC 947-3
    2200 W AC-23A, 400 V 3 phases conforming to IEC 947-3
    2200 W AC-23A, 500 V 3 phases conforming to IEC 947-3
    2200 W AC-23A, 690 V 3 phases conforming to IEC 947-3
    4800 W AC-21, 230 V 3 phases conforming to IEC 947-3
    600 W AC-3, 230 V 1 phase conforming to IEC 947-3
    8300 W AC-21, 400 V 3 phases conforming to IEC 947-3
    [Ie] rated operational current AC
    1.8 A at 690 V AC-3 3 phases conforming to IEC 947-3
    2.8 A at 500 V AC-3 3 phases conforming to IEC 947-3
    2.8 A at 690 V AC-23A 3 phases conforming to IEC 947-3
    3.3 A at 400 V AC-3 3 phases conforming to IEC 947-3
    3.8 A at 500 V AC-23A 3 phases conforming to IEC 947-3
    4.6 A at 230 V AC-3 3 phases conforming to IEC 947-3
    4.8 A at 400 V AC-23A 3 phases conforming to IEC 947-3
    5.6 A at 230 V AC-23A 3 phases conforming to IEC 947-3
    1 A at 500 V AC-15 conforming to IEC 947-5-1
    2 A at 400 V AC-15 conforming to IEC 947-5-1
    3 A at 230 V AC-15 conforming to IEC 947-5-1
    electrical durability
    1000000 cycles AC-15
    1000000 cycles AC-21
    500000 cycles AC-23
    500000 cycles AC-3
    maximum operating rate
    8333 cyc/mn AC-15
    2.5 cyc/mn AC-21
    2.5 cyc/mn AC-23
    2.5 cyc/mn AC-3
    short-circuit current
    10000 A
    short-circuit protection
    16 A cartridge fuse, type gG
    [Uimp] rated impulse withstand voltage
    4 kV in isolating function
    6 kV conforming to IEC 947-1
    contact operation
    Slow-break
    positive opening
    With
    electrical connection
    Captive screw clamp terminals flexible, clamping capacity: 2 x 1.5 mm²
    Captive screw clamp terminals solid, clamping capacity: 1 x 2.5 mm²
    mechanical durability
    1000000 cycles
    CAD overall width
    45 mm
    CAD overall height
    50 mm
    CAD overall depth
    49 mm
    net weight
    0.123 kg
    Environment (see above)
    standards
    EN/IEC 60947-3 for power circuit
    EN/IEC 60947-5-1 for control circuit
    CSA C22.2 No 14 for power circuit
    CSA C22.2 No 14 for control circuit
    UL 508 for power circuit
    UL 508 for control circuit
    product certifications
    CSA 240 V 3 hp 3 phases 2 -pole(s)
    UL 240 V 0.33 hp 1 phase 2 -pole(s)
    CSA 240 V 1 hp 1 phase
    UL 240 V 1 hp 3 phases
    protective treatment
    TC
    ambient air temperature for operation
    -25…55 °C
    ambient air temperature for storage
    -40…70 °C
    shock resistance
    30 gn conforming to IEC 68-2-27
    vibration resistance
    5 gn conforming to IEC 68-2-6 (f = 10…150 Hz)
    overvoltage category
    Class II conforming to IEC 536
    Class II conforming to NF C 20-030
    Packing Units (see above)
    Package 1 Weight
    1.000 g
    Offer Sustainability (see above)
    REACh Regulation
    REACh free of SVHC
    Yes
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Toxic heavy metal free
    Yes
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

    Filter By

    Product Public Price Discount Guaranteed Stock QTY Action
    Rp 192,303.00 100.00 % 205
    Rp 82,557.00 100.00 % 55
    Rp 49,070.00 100.00 % 185
    Rp 82,557.00 100.00 % 53
    Rp 49,070.00 100.00 % 296
    Rp 82,557.00 100.00 % 10
    HOT PROMO
    Main (see above)
    range of product
    Harmony K
    product or component type
    Complete cam switch
    component name
    K1
    [Ith] conventional free air thermal current
    12 A
    fixing mode
    Ø 16 or 22 mm hole
    cam switch head type
    With front plate 45 x 45 mm
    type of operator
    Black handle, length = 35 mm
    rotary handle padlocking
    Without
    presentation of legend
    With metallic legend black marking
    cam switch function
    Switch
    return
    Without
    off position
    With Off position
    poles description
    4P
    switching positions
    Right: 0° - 45° - 90° - 135° - 180°
    IP degree of protection
    IP65 conforming to IEC 529
    IP65 conforming to NF C 20-010
    Complementary (see above)
    number of steps
    45
    [Ui] rated insulation voltage
    690 V (pollution degree 3) conforming to IEC 60947-1
    [Ithe] conventional enclosed thermal current
    10 A
    rated operational power in W
    10500 W AC-21, 500...660 V 3 phases conforming to IEC 947-3
    1100 W AC-3, 230 V 3 phases conforming to IEC 947-3
    1500 W AC-23A, 230 V 3 phases conforming to IEC 947-3
    1500 W AC-3, 400 V 1 phase conforming to IEC 947-3
    1500 W AC-3, 400 V 3 phases conforming to IEC 947-3
    1500 W AC-3, 500 V 3 phases conforming to IEC 947-3
    1500 W AC-3, 690 V 3 phases conforming to IEC 947-3
    2200 W AC-23A, 400 V 3 phases conforming to IEC 947-3
    2200 W AC-23A, 500 V 3 phases conforming to IEC 947-3
    2200 W AC-23A, 690 V 3 phases conforming to IEC 947-3
    4800 W AC-21, 230 V 3 phases conforming to IEC 947-3
    600 W AC-3, 230 V 1 phase conforming to IEC 947-3
    8300 W AC-21, 400 V 3 phases conforming to IEC 947-3
    [Ie] rated operational current AC
    1.8 A at 690 V AC-3 3 phases conforming to IEC 947-3
    2.8 A at 500 V AC-3 3 phases conforming to IEC 947-3
    2.8 A at 690 V AC-23A 3 phases conforming to IEC 947-3
    3.3 A at 400 V AC-3 3 phases conforming to IEC 947-3
    3.8 A at 500 V AC-23A 3 phases conforming to IEC 947-3
    4.6 A at 230 V AC-3 3 phases conforming to IEC 947-3
    4.8 A at 400 V AC-23A 3 phases conforming to IEC 947-3
    5.6 A at 230 V AC-23A 3 phases conforming to IEC 947-3
    1 A at 500 V AC-15 conforming to IEC 947-5-1
    2 A at 400 V AC-15 conforming to IEC 947-5-1
    3 A at 230 V AC-15 conforming to IEC 947-5-1
    electrical durability
    1000000 cycles AC-15
    1000000 cycles AC-21
    500000 cycles AC-23
    500000 cycles AC-3
    maximum operating rate
    8333 cyc/mn AC-15
    2.5 cyc/mn AC-21
    2.5 cyc/mn AC-23
    2.5 cyc/mn AC-3
    short-circuit current
    10000 A
    short-circuit protection
    16 A cartridge fuse, type gG
    [Uimp] rated impulse withstand voltage
    4 kV in isolating function
    6 kV conforming to IEC 947-1
    contact operation
    Slow-break
    positive opening
    With
    electrical connection
    Captive screw clamp terminals flexible, clamping capacity: 2 x 1.5 mm²
    Captive screw clamp terminals solid, clamping capacity: 1 x 2.5 mm²
    mechanical durability
    1000000 cycles
    CAD overall width
    45 mm
    CAD overall height
    50 mm
    CAD overall depth
    49 mm
    net weight
    0.123 kg
    Environment (see above)
    standards
    EN/IEC 60947-3 for power circuit
    EN/IEC 60947-5-1 for control circuit
    CSA C22.2 No 14 for power circuit
    CSA C22.2 No 14 for control circuit
    UL 508 for power circuit
    UL 508 for control circuit
    product certifications
    CSA 240 V 3 hp 3 phases 2 -pole(s)
    UL 240 V 0.33 hp 1 phase 2 -pole(s)
    CSA 240 V 1 hp 1 phase
    UL 240 V 1 hp 3 phases
    protective treatment
    TC
    ambient air temperature for operation
    -25…55 °C
    ambient air temperature for storage
    -40…70 °C
    shock resistance
    30 gn conforming to IEC 68-2-27
    vibration resistance
    5 gn conforming to IEC 68-2-6 (f = 10…150 Hz)
    overvoltage category
    Class II conforming to IEC 536
    Class II conforming to NF C 20-030
    Packing Units (see above)
    Package 1 Weight
    1.000 g
    Offer Sustainability (see above)
    REACh Regulation
    REACh free of SVHC
    Yes
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Toxic heavy metal free
    Yes
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins