• Sign up now and get discount up to 47%

Schneider Multifunction control relay RM17-TE - range 183..528 V AC

Rp 2,040,790.00 Rp 1,183,658.00 1183658 IDR

Rp 2,040,790.00

Option not available

    This combination does not exist.

    Add to Cart

    Schneider Multifunction control relay RM17-TE - range 183..528 V AC
    Terjual 0
    0 (0 Rating)
    Ulasan (0)

    Rp 1,183,658.00
    42.00 % Rp 2,040,790.00 1183658 IDR

    Rp 2,040,790.00

    Option not available

    Atur Jumlah & Catatan
    Stock Total: 20
    Spesifikasi
    Main (see above)
    range of product
    Harmony Control Relays
    product or component type
    3-phase control relay
    relay type
    Multifunction control relay
    product specific application
    For 3-phase supply
    relay name
    RM17TE
    relay monitored parameters
    Undervoltage and overvoltage in window mode
    Asymmetry
    Phase sequence
    Phase failure detection
    time delay
    Adjustable 0.1...10 s, +/- 10 % of the full scale value
    switching capacity in VA
    1250 VA
    measurement range
    208...480 V voltage AC
    contacts type and composition
    1 C/O
    [Uc] control circuit voltage
    208...480 V
    Complementary (see above)
    reset time
    1500 ms time delay
    maximum switching voltage
    250 V AC
    250 V DC
    minimum switching current
    10 mA at 5 V DC
    maximum switching current
    5 A AC
    5 A DC
    supply voltage limits
    183…528 V AC
    control circuit voltage limits
    - 12 % + 10 % Un
    power consumption in VA
    0…22 VA at 400 V AC 50 Hz
    control circuit frequency
    50...60 Hz +/- 10 %
    output contacts
    1 C/O
    nominal output current
    5 A
    measurement voltage limits
    183…528 V AC
    hysteresis
    2 %
    delay at power up
    650 ms
    maximum measuring cycle
    150 ms measurement cycle as true rms value
    threshold adjustment voltage
    -2...-17 % in the range 220 V AC
    +2...+17 % in the range 480 V AC
    -2...-12 % in the range 208 V AC
    2...20 % of Un selected
    voltage range
    208...480 V phase to phase
    adjustment of asymmetry threshold
    5...15 % of Un selected
    repeat accuracy
    0.5 % for input and measurement circuit
    3 % for time delay
    measurement error
    < 0.05 %/°C with temperature variation
    < 1 % over the whole range with voltage variation
    phase failure sensitivity
    0.7 Un
    response time
    < 200 ms (in the event of a fault)
    marking
    CE
    overvoltage category
    III conforming to IEC 60664-1
    insulation resistance
    > 500 MOhm at 500 V DC conforming to IEC 60255-5
    > 500 MOhm at 500 V DC conforming to IEC 60664-1
    [Ui] rated insulation voltage
    400 V conforming to IEC 60664-1
    supply frequency
    50/60 Hz +/- 10 %
    operating position
    Any position without derating
    connections - terminals
    Screw terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable end
    Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end
    Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) flexible with cable end
    Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
    tightening torque
    0.6…1 N.m conforming to IEC 60947-1
    housing material
    Self-extinguishing plastic
    local signalling
    LED (green) for power ON
    LED (yellow) for relay ON
    mounting support
    35 mm symmetrical DIN rail conforming to EN/IEC 60715
    electrical durability
    100000 cycles
    mechanical durability
    30000000 cycles
    operating rate
    <= 360 operations/hour full load
    utilisation category
    AC-12 conforming to IEC 60947-5-1
    AC-13 conforming to IEC 60947-5-1
    AC-14 conforming to IEC 60947-5-1
    AC-15 conforming to IEC 60947-5-1
    DC-12 conforming to IEC 60947-5-1
    DC-13 conforming to IEC 60947-5-1
    safety reliability data
    MTTFd = 502.2 years
    B10d = 470000
    width
    17.5 mm
    net weight
    0.13 kg
    Environment (see above)
    electromagnetic compatibility
    Emission standard for industrial environments conforming to EN/IEC 61000-6-4
    Emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3
    Immunity for industrial environments conforming to EN/IEC 61000-6-2
    standards
    EN/IEC 60255-1
    product certifications
    GOST
    C-Tick
    CSA
    UL
    GL
    directives
    89/336/EEC - electromagnetic compatibility
    73/23/EEC - low voltage directive
    ambient air temperature for storage
    -40…70 °C
    ambient air temperature for operation
    -20…50 °C
    relative humidity
    95 % at 55 °C conforming to IEC 60068-2-30
    vibration resistance
    0.35 mm (f= 5…57.6 Hz) conforming to IEC 60068-2-6
    1 gn (f= 57.6…150 Hz) conforming to IEC 60255-21-1
    shock resistance
    15 gn for 11 ms conforming to IEC 60255-21-1
    IP degree of protection
    IP20 (terminals) conforming to IEC 60529
    IP30 (casing) conforming to IEC 60529
    pollution degree
    3 conforming to IEC 60664-1
    dielectric test voltage
    2 kV, 1 min AC 50 Hz conforming to IEC 60255-5
    2 kV, 1 min AC 50 Hz conforming to IEC 60664-1
    non-dissipating shock wave
    4 kV conforming to IEC 60255-5
    4 kV conforming to IEC 60664-1
    4 kV conforming to IEC 61000-4-5
    Packing Units (see above)
    Unit Type of Package 1
    PCE
    Number of Units in Package 1
    1
    Package 1 Weight
    89 g
    Package 1 Height
    2.7 cm
    Package 1 width
    7.7 cm
    Package 1 Length
    9.6 cm
    Unit Type of Package 2
    S02
    Number of Units in Package 2
    48
    Package 2 Weight
    5.017 kg
    Package 2 Height
    15 cm
    Package 2 width
    30 cm
    Package 2 Length
    40 cm
    Offer Sustainability (see above)
    Sustainable offer status
    Green Premium product
    REACh Regulation
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
    California proposition 65
    WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    Contractual warranty (see above)
    Warranty
    12 months

    Filter By

    Product Public Price Discount Guaranteed Stock QTY Action
    Rp 100,792.00 100.00 % 17
    Rp 144,558.00 100.00 % 22
    Rp 100,792.00 100.00 % 31
    Rp 100,792.00 100.00 % 8
    Rp 92,835.00 100.00 % 10
    Rp 92,835.00 100.00 % 10
    Main (see above)
    range of product
    Harmony Control Relays
    product or component type
    3-phase control relay
    relay type
    Multifunction control relay
    product specific application
    For 3-phase supply
    relay name
    RM17TE
    relay monitored parameters
    Undervoltage and overvoltage in window mode
    Asymmetry
    Phase sequence
    Phase failure detection
    time delay
    Adjustable 0.1...10 s, +/- 10 % of the full scale value
    switching capacity in VA
    1250 VA
    measurement range
    208...480 V voltage AC
    contacts type and composition
    1 C/O
    [Uc] control circuit voltage
    208...480 V
    Complementary (see above)
    reset time
    1500 ms time delay
    maximum switching voltage
    250 V AC
    250 V DC
    minimum switching current
    10 mA at 5 V DC
    maximum switching current
    5 A AC
    5 A DC
    supply voltage limits
    183…528 V AC
    control circuit voltage limits
    - 12 % + 10 % Un
    power consumption in VA
    0…22 VA at 400 V AC 50 Hz
    control circuit frequency
    50...60 Hz +/- 10 %
    output contacts
    1 C/O
    nominal output current
    5 A
    measurement voltage limits
    183…528 V AC
    hysteresis
    2 %
    delay at power up
    650 ms
    maximum measuring cycle
    150 ms measurement cycle as true rms value
    threshold adjustment voltage
    -2...-17 % in the range 220 V AC
    +2...+17 % in the range 480 V AC
    -2...-12 % in the range 208 V AC
    2...20 % of Un selected
    voltage range
    208...480 V phase to phase
    adjustment of asymmetry threshold
    5...15 % of Un selected
    repeat accuracy
    0.5 % for input and measurement circuit
    3 % for time delay
    measurement error
    < 0.05 %/°C with temperature variation
    < 1 % over the whole range with voltage variation
    phase failure sensitivity
    0.7 Un
    response time
    < 200 ms (in the event of a fault)
    marking
    CE
    overvoltage category
    III conforming to IEC 60664-1
    insulation resistance
    > 500 MOhm at 500 V DC conforming to IEC 60255-5
    > 500 MOhm at 500 V DC conforming to IEC 60664-1
    [Ui] rated insulation voltage
    400 V conforming to IEC 60664-1
    supply frequency
    50/60 Hz +/- 10 %
    operating position
    Any position without derating
    connections - terminals
    Screw terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable end
    Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end
    Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) flexible with cable end
    Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
    tightening torque
    0.6…1 N.m conforming to IEC 60947-1
    housing material
    Self-extinguishing plastic
    local signalling
    LED (green) for power ON
    LED (yellow) for relay ON
    mounting support
    35 mm symmetrical DIN rail conforming to EN/IEC 60715
    electrical durability
    100000 cycles
    mechanical durability
    30000000 cycles
    operating rate
    <= 360 operations/hour full load
    utilisation category
    AC-12 conforming to IEC 60947-5-1
    AC-13 conforming to IEC 60947-5-1
    AC-14 conforming to IEC 60947-5-1
    AC-15 conforming to IEC 60947-5-1
    DC-12 conforming to IEC 60947-5-1
    DC-13 conforming to IEC 60947-5-1
    safety reliability data
    MTTFd = 502.2 years
    B10d = 470000
    width
    17.5 mm
    net weight
    0.13 kg
    Environment (see above)
    electromagnetic compatibility
    Emission standard for industrial environments conforming to EN/IEC 61000-6-4
    Emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3
    Immunity for industrial environments conforming to EN/IEC 61000-6-2
    standards
    EN/IEC 60255-1
    product certifications
    GOST
    C-Tick
    CSA
    UL
    GL
    directives
    89/336/EEC - electromagnetic compatibility
    73/23/EEC - low voltage directive
    ambient air temperature for storage
    -40…70 °C
    ambient air temperature for operation
    -20…50 °C
    relative humidity
    95 % at 55 °C conforming to IEC 60068-2-30
    vibration resistance
    0.35 mm (f= 5…57.6 Hz) conforming to IEC 60068-2-6
    1 gn (f= 57.6…150 Hz) conforming to IEC 60255-21-1
    shock resistance
    15 gn for 11 ms conforming to IEC 60255-21-1
    IP degree of protection
    IP20 (terminals) conforming to IEC 60529
    IP30 (casing) conforming to IEC 60529
    pollution degree
    3 conforming to IEC 60664-1
    dielectric test voltage
    2 kV, 1 min AC 50 Hz conforming to IEC 60255-5
    2 kV, 1 min AC 50 Hz conforming to IEC 60664-1
    non-dissipating shock wave
    4 kV conforming to IEC 60255-5
    4 kV conforming to IEC 60664-1
    4 kV conforming to IEC 61000-4-5
    Packing Units (see above)
    Unit Type of Package 1
    PCE
    Number of Units in Package 1
    1
    Package 1 Weight
    89 g
    Package 1 Height
    2.7 cm
    Package 1 width
    7.7 cm
    Package 1 Length
    9.6 cm
    Unit Type of Package 2
    S02
    Number of Units in Package 2
    48
    Package 2 Weight
    5.017 kg
    Package 2 Height
    15 cm
    Package 2 width
    30 cm
    Package 2 Length
    40 cm
    Offer Sustainability (see above)
    Sustainable offer status
    Green Premium product
    REACh Regulation
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
    California proposition 65
    WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    Contractual warranty (see above)
    Warranty
    12 months