Schneider TeSys K contactor - 4P (2 NO + 2 NC) - AC-1 440 V 20 A - 220.230 V AC coil
# of Pole : 4
Arus Pengenal (A) : 20A
Coil AC : 220V (M7)
Schneider TeSys K contactor - 4P (2 NO + 2 NC) - AC-1 440 V 20 A - 220.230 V AC coil
Terjual 0
0 (0 Rating)
Ulasan (0)
Rp 431,514.00
48.00 %
Rp 829,836.00
Rp 829,836.00
Option not available
Spesifikasi
| range | TeSys | |
|---|---|---|
| product or component type | Contactor | |
| product name | TeSys K | |
| device application | Control | |
| contactor application | Resistive load |
| utilisation category | AC-1 | |
|---|---|---|
| poles description | 4P | |
| power pole contact composition | 2 NO + 2 NC | |
| [Ue] rated operational voltage | Power circuit: 690 V AC 50/60 Hz | |
| control circuit type | AC at 50/60 Hz | |
| [Uc] control circuit voltage | 220...230 V AC 50/60 Hz | |
| [Uimp] rated impulse withstand voltage | 8 kV | |
| overvoltage category | III | |
| [Ith] conventional free air thermal current | 20 A (at 50 °C) for power circuit | |
| Irms rated making capacity | 110 A AC for power circuit conforming to NF C 63-110 110 A AC for power circuit conforming to IEC 60947 | |
| rated breaking capacity | 110 A at 415 V conforming to IEC 60947 110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 110 A at 220...230 V conforming to IEC 60947 110 A at 380...400 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947 | |
| associated fuse rating | 25 A gG at <= 440 V for power circuit 25 A aM for power circuit | |
| average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit | |
| [Ui] rated insulation voltage | Power circuit: 600 V conforming to UL 508 Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V conforming to CSA C22.2 No 14 | |
| inrush power in VA | 30 VA (at 20 °C) | |
| hold-in power consumption in VA | 4.5 VA (at 20 °C) | |
| heat dissipation | 1.3 W | |
| control circuit voltage limits | Operational: 0.8...1.15 Uc (at <50 °C) Drop-out: 0.2...0.75 Uc (at <50 °C) | |
| connections - terminals | Screw clamp terminals 1 cable(s) 1.5…4 mm²solid Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end Screw clamp terminals 2 cable(s) 1.5…4 mm²solid Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end | |
| maximum operating rate | 3600 cyc/h | |
| signalling circuit frequency | <= 400 Hz | |
| mounting support | Plate Rail | |
| tightening torque | 1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2 1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm | |
| operating time | 10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing 15...25 ms coil de-energisation and NC closing 5...15 ms coil energisation and NC opening | |
| safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | |
| mechanical durability | 10 Mcycles | |
| electrical durability | 0.18 Mcycles 20 A AC-1 at Ue <= 440 V | |
| mechanical robustness | Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 | |
| depth | 57 mm |
| standards | BS 5424 IEC 60947 NF C 63-110 VDE 0660 | |
|---|---|---|
| product certifications | UL CSA | |
| IP degree of protection | IP2x conforming to VDE 0106 | |
| protective treatment | TC conforming to IEC 60068 TC conforming to DIN 50016 | |
| ambient air temperature for storage | -50…80 °C | |
| operating altitude | 2000 m without derating | |
| flame retardance | V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102 |
| Unit Type of Package 1 | PCE | |
|---|---|---|
| Number of Units in Package 1 | 1 | |
| Package 1 Weight | 178 g | |
| Package 1 Height | 4.8 cm | |
| Package 1 width | 6.2 cm | |
| Package 1 Length | 6.5 cm | |
| Unit Type of Package 2 | S02 | |
| Number of Units in Package 2 | 50 | |
| Package 2 Weight | 9.35 kg | |
| Package 2 Height | 15 cm | |
| Package 2 width | 30 cm | |
| Package 2 Length | 40 cm |
| Sustainable offer status | Green Premium product | |
|---|---|---|
| REACh Regulation | ||
| REACh free of SVHC | Yes | |
| EU RoHS Directive | Compliant EU RoHS Declaration | |
| Toxic heavy metal free | Yes | |
| Mercury free | Yes | |
| RoHS exemption information | ||
| China RoHS Regulation | China RoHS declaration Pro-active China RoHS declaration (out of China RoHS legal scope) | |
| Environmental Disclosure | ||
| Circularity Profile | ||
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | |
| California proposition 65 | WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov |
| Warranty | 12 months |
|---|
Specifications for Schneider TeSys K contactor - 4P (2 NO + 2 NC) - AC-1 440 V 20 A - 220.230 V AC coil
| General Information | |
|---|---|
| # of Pole | 4 |
| Arus Pengenal (A) | 20A |
| Uncategorized | |
| Coil AC | 220V (M7) |
| range | TeSys | |
|---|---|---|
| product or component type | Contactor | |
| product name | TeSys K | |
| device application | Control | |
| contactor application | Resistive load |
| utilisation category | AC-1 | |
|---|---|---|
| poles description | 4P | |
| power pole contact composition | 2 NO + 2 NC | |
| [Ue] rated operational voltage | Power circuit: 690 V AC 50/60 Hz | |
| control circuit type | AC at 50/60 Hz | |
| [Uc] control circuit voltage | 220...230 V AC 50/60 Hz | |
| [Uimp] rated impulse withstand voltage | 8 kV | |
| overvoltage category | III | |
| [Ith] conventional free air thermal current | 20 A (at 50 °C) for power circuit | |
| Irms rated making capacity | 110 A AC for power circuit conforming to NF C 63-110 110 A AC for power circuit conforming to IEC 60947 | |
| rated breaking capacity | 110 A at 415 V conforming to IEC 60947 110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 110 A at 220...230 V conforming to IEC 60947 110 A at 380...400 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947 | |
| associated fuse rating | 25 A gG at <= 440 V for power circuit 25 A aM for power circuit | |
| average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit | |
| [Ui] rated insulation voltage | Power circuit: 600 V conforming to UL 508 Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V conforming to CSA C22.2 No 14 | |
| inrush power in VA | 30 VA (at 20 °C) | |
| hold-in power consumption in VA | 4.5 VA (at 20 °C) | |
| heat dissipation | 1.3 W | |
| control circuit voltage limits | Operational: 0.8...1.15 Uc (at <50 °C) Drop-out: 0.2...0.75 Uc (at <50 °C) | |
| connections - terminals | Screw clamp terminals 1 cable(s) 1.5…4 mm²solid Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end Screw clamp terminals 2 cable(s) 1.5…4 mm²solid Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end | |
| maximum operating rate | 3600 cyc/h | |
| signalling circuit frequency | <= 400 Hz | |
| mounting support | Plate Rail | |
| tightening torque | 1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2 1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm | |
| operating time | 10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing 15...25 ms coil de-energisation and NC closing 5...15 ms coil energisation and NC opening | |
| safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | |
| mechanical durability | 10 Mcycles | |
| electrical durability | 0.18 Mcycles 20 A AC-1 at Ue <= 440 V | |
| mechanical robustness | Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 | |
| depth | 57 mm |
| standards | BS 5424 IEC 60947 NF C 63-110 VDE 0660 | |
|---|---|---|
| product certifications | UL CSA | |
| IP degree of protection | IP2x conforming to VDE 0106 | |
| protective treatment | TC conforming to IEC 60068 TC conforming to DIN 50016 | |
| ambient air temperature for storage | -50…80 °C | |
| operating altitude | 2000 m without derating | |
| flame retardance | V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102 |
| Unit Type of Package 1 | PCE | |
|---|---|---|
| Number of Units in Package 1 | 1 | |
| Package 1 Weight | 178 g | |
| Package 1 Height | 4.8 cm | |
| Package 1 width | 6.2 cm | |
| Package 1 Length | 6.5 cm | |
| Unit Type of Package 2 | S02 | |
| Number of Units in Package 2 | 50 | |
| Package 2 Weight | 9.35 kg | |
| Package 2 Height | 15 cm | |
| Package 2 width | 30 cm | |
| Package 2 Length | 40 cm |
| Sustainable offer status | Green Premium product | |
|---|---|---|
| REACh Regulation | ||
| REACh free of SVHC | Yes | |
| EU RoHS Directive | Compliant EU RoHS Declaration | |
| Toxic heavy metal free | Yes | |
| Mercury free | Yes | |
| RoHS exemption information | ||
| China RoHS Regulation | China RoHS declaration Pro-active China RoHS declaration (out of China RoHS legal scope) | |
| Environmental Disclosure | ||
| Circularity Profile | ||
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | |
| California proposition 65 | WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov |
| Warranty | 12 months |
|---|
Recently Viewed Products
Schneider TeSys K contactor - 4P (2 NO + 2 NC) - AC-1 440 V 20 A - 220.230 V AC coil
Rp 829,836.00
Rp 478,980.00
HOT PROMO