Schneider TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 125 A - 220 V AC 50/60 Hz coil
# of Pole : 4
Arus Pengenal (A) : 125A
Coil AC : 220V (M7)
Rp 3,463,101.00
44.00 %
Rp 6,184,109.00
Rp 6,184,109.00
Option not available
[Deskripsi] 1. product name : TeSys D 2. product or component type : Contactor 3. device short name : LC1D 4. contactor application : Resistive load 5. utilisation category : AC-1 6. poles description : 4P 7. [Ue] rated operational voltage : -Power circuit: <= 690 V AC 25...400 Hz -Power circuit: <= 300 V DC 8. [Ie] rated operational current : 125 A (at <60 °C) at <= 440 V AC AC-1 for power circuit 9. control circuit type : AC at 50/60 Hz 10. [Uc] control circuit voltage : 220 V AC 50/60 Hz 11. [Uimp] rated impulse withstand voltage : 8 kV conforming to IEC 60947 12. overvoltage category : III 13. [Ith] conventional free air thermal current : 125 A (at 60 °C) for power circuit 14. Irms rated making capacity : 1100 A at 440 V for power circuit conforming to IEC 60947 15. rated breaking capacity : 1100 A at 440 V for power circuit conforming to IEC 60947 16. [Icw] rated short-time withstand current : -640 A 40 °C - 10 s for power circuit -990 A 40 °C - 1 s for power circuit -135 A 40 °C - 10 min for power circuit -320 A 40 °C - 1 min for power circuit 17. associated fuse rating : -200 A gG at <= 690 V coordination type 1 for power circuit -160 A gG at <= 690 V coordination type 2 for power circuit 18. average impedance : 0.8 mOhm - Ith 125 A 50 Hz for power circuit 19. [Ui] rated insulation voltage : -Power circuit: 690 V conforming to IEC 60947-4-1 -Power circuit: 600 V CSA certified -Power circuit: 600 V UL certified 20. electrical durability : 0.8 Mcycles 60 A AC-1 at Ue <= 440 V 21. power dissipation per pole : 12.5 W AC-1 22. safety cover : With 23. mounting support : -Plate -RaiL 24. standards : -CSA C22.2 No 14 -EN 60947-4-1 -EN 60947-5-1 -IEC 60947-4-1 -IEC 60947-5-1 -UL 508 25. product certifications : -DNV -UL -LROS (Lloyds register of shipping) -CSA -CCC -GL -GOST -RINA -BV 26. coil technology : Without built-in suppressor module 27. control circuit voltage limits : -Drop-out: 0.3...0.6 Uc AC 50/60 Hz (at 60 °C) -Operational: 0.8...1.1 Uc AC 50 Hz (at 60 °C) -Operational: 0.85...1.1 Uc AC 60 Hz (at 60 °C) 28. time constant : - 29. inrush power in VA : -245 VA 60 Hz cos phi 0.75 (at 20 °C) -245 VA 50 Hz cos phi 0.75 (at 20 °C) 30. hold-in power consumption in VA : -26 VA 60 Hz cos phi 0.3 (at 20 °C) -26 VA 50 Hz cos phi 0.3 (at 20 °C) 31. heat dissipation : 6…10 W at 50/60 Hz 32. IP degree of protection : IP20 front face conforming to IEC 60529 33. protective treatment : TH conforming to IEC 60068-2-30 34. pollution degree : 3 35. ambient air temperature for operation : -5…60 °C 36. ambient air temperature for storage : -60…80 °C 37. permissible ambient air temperature around the device : -40…70 °C at Uc 38. operating altitude : 3000 m without 39. fire resistance : 850 °C conforming to IEC 60695-2-1 40. flame retardance : V1 conforming to UL 94 41. mechanical robustness : -Vibrations contactor open: 2 Gn, 5...300 Hz -Vibrations contactor closed: 4 Gn, 5...300 Hz -Shocks contactor closed: 15 Gn for 11 ms -Shocks contactor open: 10 Gn for 11 ms 42. height : 127 mm 43. width : 96 mm 44. depth : 125 mm 45. net weight : 1.76 kg
range | TeSys | |
---|---|---|
product name | TeSys D | |
product or component type | Contactor | |
device short name | LC1D | |
contactor application | Resistive load | |
utilisation category | AC-1 | |
poles description | 4P | |
power pole contact composition | 4 NO | |
[Ue] rated operational voltage | Power circuit: <= 300 V DC 25...400 Hz Power circuit: <= 690 V AC | |
[Ie] rated operational current | 125 A (at <60 °C) at <= 440 V AC AC-1 for power circuit | |
control circuit type | AC at 50/60 Hz | |
[Uc] control circuit voltage | 220 V AC 50/60 Hz | |
[Uimp] rated impulse withstand voltage | 8 kV conforming to IEC 60947 | |
overvoltage category | III | |
[Ith] conventional free air thermal current | 125 A (at 60 °C) for power circuit | |
Irms rated making capacity | 1100 A at 440 V for power circuit conforming to IEC 60947 | |
rated breaking capacity | 1100 A at 440 V for power circuit conforming to IEC 60947 | |
[Icw] rated short-time withstand current | 640 A 40 °C - 10 s for power circuit 990 A 40 °C - 1 s for power circuit 135 A 40 °C - 10 min for power circuit 320 A 40 °C - 1 min for power circuit | |
associated fuse rating | 200 A gG at <= 690 V coordination type 1 for power circuit 160 A gG at <= 690 V coordination type 2 for power circuit | |
average impedance | 0.8 mOhm - Ith 125 A 50 Hz for power circuit | |
[Ui] rated insulation voltage | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Power circuit: 1000 V conforming to IEC 60947-4-1 | |
electrical durability | 0.8 Mcycles 125 A AC-1 at Ue <= 440 V | |
power dissipation per pole | 12.5 W AC-1 | |
Front cover | Without | |
mounting support | Rail Plate | |
standards | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | |
product certifications | DNV LROS (Lloyds register of shipping) GL CSA CCC RINA UL GOST BV | |
connections - terminals | Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end Power circuit: connector 1 cable(s) 4…50 mm²flexible without cable end Power circuit: connector 2 cable(s) 4…25 mm²flexible without cable end Power circuit: connector 1 cable(s) 4…50 mm²flexible with cable end Power circuit: connector 2 cable(s) 4…16 mm²flexible with cable end Power circuit: connector 1 cable(s) 4…50 mm²solid without cable end Power circuit: connector 2 cable(s) 4…25 mm²solid without cable end | |
tightening torque | Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 12 N.m - on connector - with screwdriver flat Ø 6 to Ø 8 mm Power circuit: 12 N.m - on connector hexagonal screw head 4 mm | |
operating time | 20...35 ms closing 6...20 ms opening | |
safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | |
mechanical durability | 4 Mcycles | |
maximum operating rate | 3600 cyc/h 60 °C |
coil technology | Without built-in suppressor module | |
---|---|---|
control circuit voltage limits | 0.85...1.1 Uc (-40…55 °C):operational AC 60 Hz 0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz 0.8...1.1 Uc (-40…55 °C):operational AC 50 Hz 1...1.1 Uc (55…70 °C):operational AC 50/60 Hz | |
inrush power in VA | 245 VA 60 Hz cos phi 0.75 (at 20 °C) 245 VA 50 Hz cos phi 0.75 (at 20 °C) | |
hold-in power consumption in VA | 26 VA 60 Hz cos phi 0.3 (at 20 °C) 26 VA 50 Hz cos phi 0.3 (at 20 °C) | |
heat dissipation | 6…10 W at 50/60 Hz |
IP degree of protection | IP20 front face conforming to IEC 60529 | |
---|---|---|
protective treatment | TH conforming to IEC 60068-2-30 | |
pollution degree | 3 | |
ambient air temperature for operation | -40…60 °C 60…70 °C with derating | |
ambient air temperature for storage | -60…80 °C | |
operating altitude | 0...3000 m | |
fire resistance | 850 °C conforming to IEC 60695-2-1 | |
flame retardance | V1 conforming to UL 94 | |
mechanical robustness | Vibrations contactor open: 2 Gn, 5...300 Hz Shocks contactor open: 8 Gn for 11 ms Vibrations contactor closed: 3 Gn, 5...300 Hz Shocks contactor closed: 10 Gn for 11 ms | |
height | 127 mm | |
width | 96 mm | |
depth | 125 mm | |
net weight | 1.76 kg |
Unit Type of Package 1 | PCE | |
---|---|---|
Number of Units in Package 1 | 1 | |
Package 1 Weight | 1.701 kg | |
Package 1 Height | 11 cm | |
Package 1 width | 13.5 cm | |
Package 1 Length | 15.5 cm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
REACh free of SVHC | Yes | |
EU RoHS Directive | Compliant EU RoHS Declaration | |
Toxic heavy metal free | Yes | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | China RoHS declaration Pro-active China RoHS declaration (out of China RoHS legal scope) | |
Environmental Disclosure | ||
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | |
PVC free | Yes | |
California proposition 65 | WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov |
Warranty | 12 months |
---|
Specifications for Schneider TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 125 A - 220 V AC 50/60 Hz coil
General Information | |
---|---|
# of Pole | 4 |
Arus Pengenal (A) | 125A |
Uncategorized | |
Coil AC | 220V (M7) |
[Deskripsi] 1. product name : TeSys D 2. product or component type : Contactor 3. device short name : LC1D 4. contactor application : Resistive load 5. utilisation category : AC-1 6. poles description : 4P 7. [Ue] rated operational voltage : -Power circuit: <= 690 V AC 25...400 Hz -Power circuit: <= 300 V DC 8. [Ie] rated operational current : 125 A (at <60 °C) at <= 440 V AC AC-1 for power circuit 9. control circuit type : AC at 50/60 Hz 10. [Uc] control circuit voltage : 220 V AC 50/60 Hz 11. [Uimp] rated impulse withstand voltage : 8 kV conforming to IEC 60947 12. overvoltage category : III 13. [Ith] conventional free air thermal current : 125 A (at 60 °C) for power circuit 14. Irms rated making capacity : 1100 A at 440 V for power circuit conforming to IEC 60947 15. rated breaking capacity : 1100 A at 440 V for power circuit conforming to IEC 60947 16. [Icw] rated short-time withstand current : -640 A 40 °C - 10 s for power circuit -990 A 40 °C - 1 s for power circuit -135 A 40 °C - 10 min for power circuit -320 A 40 °C - 1 min for power circuit 17. associated fuse rating : -200 A gG at <= 690 V coordination type 1 for power circuit -160 A gG at <= 690 V coordination type 2 for power circuit 18. average impedance : 0.8 mOhm - Ith 125 A 50 Hz for power circuit 19. [Ui] rated insulation voltage : -Power circuit: 690 V conforming to IEC 60947-4-1 -Power circuit: 600 V CSA certified -Power circuit: 600 V UL certified 20. electrical durability : 0.8 Mcycles 60 A AC-1 at Ue <= 440 V 21. power dissipation per pole : 12.5 W AC-1 22. safety cover : With 23. mounting support : -Plate -RaiL 24. standards : -CSA C22.2 No 14 -EN 60947-4-1 -EN 60947-5-1 -IEC 60947-4-1 -IEC 60947-5-1 -UL 508 25. product certifications : -DNV -UL -LROS (Lloyds register of shipping) -CSA -CCC -GL -GOST -RINA -BV 26. coil technology : Without built-in suppressor module 27. control circuit voltage limits : -Drop-out: 0.3...0.6 Uc AC 50/60 Hz (at 60 °C) -Operational: 0.8...1.1 Uc AC 50 Hz (at 60 °C) -Operational: 0.85...1.1 Uc AC 60 Hz (at 60 °C) 28. time constant : - 29. inrush power in VA : -245 VA 60 Hz cos phi 0.75 (at 20 °C) -245 VA 50 Hz cos phi 0.75 (at 20 °C) 30. hold-in power consumption in VA : -26 VA 60 Hz cos phi 0.3 (at 20 °C) -26 VA 50 Hz cos phi 0.3 (at 20 °C) 31. heat dissipation : 6…10 W at 50/60 Hz 32. IP degree of protection : IP20 front face conforming to IEC 60529 33. protective treatment : TH conforming to IEC 60068-2-30 34. pollution degree : 3 35. ambient air temperature for operation : -5…60 °C 36. ambient air temperature for storage : -60…80 °C 37. permissible ambient air temperature around the device : -40…70 °C at Uc 38. operating altitude : 3000 m without 39. fire resistance : 850 °C conforming to IEC 60695-2-1 40. flame retardance : V1 conforming to UL 94 41. mechanical robustness : -Vibrations contactor open: 2 Gn, 5...300 Hz -Vibrations contactor closed: 4 Gn, 5...300 Hz -Shocks contactor closed: 15 Gn for 11 ms -Shocks contactor open: 10 Gn for 11 ms 42. height : 127 mm 43. width : 96 mm 44. depth : 125 mm 45. net weight : 1.76 kg
range | TeSys | |
---|---|---|
product name | TeSys D | |
product or component type | Contactor | |
device short name | LC1D | |
contactor application | Resistive load | |
utilisation category | AC-1 | |
poles description | 4P | |
power pole contact composition | 4 NO | |
[Ue] rated operational voltage | Power circuit: <= 300 V DC 25...400 Hz Power circuit: <= 690 V AC | |
[Ie] rated operational current | 125 A (at <60 °C) at <= 440 V AC AC-1 for power circuit | |
control circuit type | AC at 50/60 Hz | |
[Uc] control circuit voltage | 220 V AC 50/60 Hz | |
[Uimp] rated impulse withstand voltage | 8 kV conforming to IEC 60947 | |
overvoltage category | III | |
[Ith] conventional free air thermal current | 125 A (at 60 °C) for power circuit | |
Irms rated making capacity | 1100 A at 440 V for power circuit conforming to IEC 60947 | |
rated breaking capacity | 1100 A at 440 V for power circuit conforming to IEC 60947 | |
[Icw] rated short-time withstand current | 640 A 40 °C - 10 s for power circuit 990 A 40 °C - 1 s for power circuit 135 A 40 °C - 10 min for power circuit 320 A 40 °C - 1 min for power circuit | |
associated fuse rating | 200 A gG at <= 690 V coordination type 1 for power circuit 160 A gG at <= 690 V coordination type 2 for power circuit | |
average impedance | 0.8 mOhm - Ith 125 A 50 Hz for power circuit | |
[Ui] rated insulation voltage | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Power circuit: 1000 V conforming to IEC 60947-4-1 | |
electrical durability | 0.8 Mcycles 125 A AC-1 at Ue <= 440 V | |
power dissipation per pole | 12.5 W AC-1 | |
Front cover | Without | |
mounting support | Rail Plate | |
standards | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | |
product certifications | DNV LROS (Lloyds register of shipping) GL CSA CCC RINA UL GOST BV | |
connections - terminals | Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end Power circuit: connector 1 cable(s) 4…50 mm²flexible without cable end Power circuit: connector 2 cable(s) 4…25 mm²flexible without cable end Power circuit: connector 1 cable(s) 4…50 mm²flexible with cable end Power circuit: connector 2 cable(s) 4…16 mm²flexible with cable end Power circuit: connector 1 cable(s) 4…50 mm²solid without cable end Power circuit: connector 2 cable(s) 4…25 mm²solid without cable end | |
tightening torque | Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 12 N.m - on connector - with screwdriver flat Ø 6 to Ø 8 mm Power circuit: 12 N.m - on connector hexagonal screw head 4 mm | |
operating time | 20...35 ms closing 6...20 ms opening | |
safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | |
mechanical durability | 4 Mcycles | |
maximum operating rate | 3600 cyc/h 60 °C |
coil technology | Without built-in suppressor module | |
---|---|---|
control circuit voltage limits | 0.85...1.1 Uc (-40…55 °C):operational AC 60 Hz 0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz 0.8...1.1 Uc (-40…55 °C):operational AC 50 Hz 1...1.1 Uc (55…70 °C):operational AC 50/60 Hz | |
inrush power in VA | 245 VA 60 Hz cos phi 0.75 (at 20 °C) 245 VA 50 Hz cos phi 0.75 (at 20 °C) | |
hold-in power consumption in VA | 26 VA 60 Hz cos phi 0.3 (at 20 °C) 26 VA 50 Hz cos phi 0.3 (at 20 °C) | |
heat dissipation | 6…10 W at 50/60 Hz |
IP degree of protection | IP20 front face conforming to IEC 60529 | |
---|---|---|
protective treatment | TH conforming to IEC 60068-2-30 | |
pollution degree | 3 | |
ambient air temperature for operation | -40…60 °C 60…70 °C with derating | |
ambient air temperature for storage | -60…80 °C | |
operating altitude | 0...3000 m | |
fire resistance | 850 °C conforming to IEC 60695-2-1 | |
flame retardance | V1 conforming to UL 94 | |
mechanical robustness | Vibrations contactor open: 2 Gn, 5...300 Hz Shocks contactor open: 8 Gn for 11 ms Vibrations contactor closed: 3 Gn, 5...300 Hz Shocks contactor closed: 10 Gn for 11 ms | |
height | 127 mm | |
width | 96 mm | |
depth | 125 mm | |
net weight | 1.76 kg |
Unit Type of Package 1 | PCE | |
---|---|---|
Number of Units in Package 1 | 1 | |
Package 1 Weight | 1.701 kg | |
Package 1 Height | 11 cm | |
Package 1 width | 13.5 cm | |
Package 1 Length | 15.5 cm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
REACh free of SVHC | Yes | |
EU RoHS Directive | Compliant EU RoHS Declaration | |
Toxic heavy metal free | Yes | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | China RoHS declaration Pro-active China RoHS declaration (out of China RoHS legal scope) | |
Environmental Disclosure | ||
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | |
PVC free | Yes | |
California proposition 65 | WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov |
Warranty | 12 months |
---|