Schneider EasyPact TVS contactor 3P(3 NO) - AC-3 - 440 V 95A - 48 V AC coil
# of Pole : 3
Arus Pengenal (A) : 95A
Coil AC : 48V (E7)
Schneider EasyPact TVS contactor 3P(3 NO) - AC-3 - 440 V 95A - 48 V AC coil
Terjual 0
0 (0 Rating)
Ulasan (0)
Rp 1,505,033.00
49.00 %
Rp 2,951,046.00
Rp 2,951,046.00
Option not available
Spesifikasi
range | EasyPact | |
---|---|---|
product name | EasyPact TVS | |
product or component type | Contactor | |
device short name | LC1E | |
contactor application | Resistive load Motor control | |
utilisation category | AC-3 AC-1 | |
poles description | 3P | |
power pole contact composition | 3 NO | |
[Ue] rated operational voltage | Power circuit: <= 690 V AC 50/60 Hz | |
[Ie] rated operational current | 95 A (at <55 °C) at <= 440 V AC AC-3 for power circuit 125 A (at <55 °C) at <= 440 V AC AC-1 for power circuit | |
motor power kW | 45 kW at 415 V 45 kW at 440 V 45 kW at 500 V 25 kW at 220...230 V AC 50/60 Hz 45 kW at 380...400 V 55 kW at 660...690 V | |
control circuit type | AC at 50/60 Hz | |
[Uc] control circuit voltage | 48 V AC 50/60 Hz | |
height | 127 mm | |
width | 85 mm | |
depth | 121 mm | |
net weight | 1.52 kg | |
colour | Grey (RAL 7011) |
auxiliary contact composition | 1 NO + 1 NC | |
---|---|---|
[Uimp] rated impulse withstand voltage | 6 kV coil not connected to the power circuit conforming to IEC 60947 | |
[Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 | |
overvoltage category | III | |
Irms rated making capacity | 950 A at 440 V AC for power circuit conforming to IEC 60947-4-1 | |
rated breaking capacity | 760 A at 440 V for power circuit conforming to IEC 60947 | |
[Icw] rated short-time withstand current | 135 A 40 °C - 600 s for power circuit 800 A 40 °C - 10 s for power circuit 400 A 40 °C - 60 s for power circuit | |
associated fuse rating | 10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1 160 A gG at <= 690 V coordination type 1 for power circuit | |
average impedance | 0.8 mOhm - Ith 120 A 50 Hz for power circuit | |
power dissipation per pole | 7.2 W AC-3 12 W AC-1 | |
control circuit voltage limits | Operational: 0.85...1.1 Uc at 50/60 Hz (at <55 °C) Drop-out: 0.3...0.6 Uc at 50/60 Hz (at <55 °C) | |
operating time | 20...35 ms on closing 6...30 ms on opening | |
mechanical durability | 300000 cycles | |
maximum operating rate | 1200 cyc/h 60 °C | |
inrush power in VA | 200 VA 50 Hz cos phi 0.75 (at 20 °C) 220 VA 60 Hz cos phi 0.75 (at 20 °C) | |
hold-in power consumption in VA | 22 VA 60 Hz cos phi 0.3 (at 20 °C) 20 VA 50 Hz cos phi 0.3 (at 20 °C) | |
heat dissipation | 6…10 W for control circuit | |
minimum switching current | 5 mA for control circuit | |
minimum switching voltage | 17 V for control circuit | |
non-overlap time | 1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact | |
insulation resistance | > 10 MOhm for control circuit | |
electrical durability | 350000 cycles AC-3 900000 cycles AC-1 | |
mounting support | Plate DIN rail | |
connections - terminals | Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 1 4…50 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 4…16 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 4…50 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 2 4…50 mm² - cable stiffness: solid without cable end | |
Recommended tightening torque | Control circuit: 1.2 N.m Power circuit: 12 N.m | |
Max tightening torque | Control circuit: 1.4 N.m Power circuit: 13.5 N.m |
standards | IEC 60947-5-1 IEC 60947-1 IEC 60947-4-1 | |
---|---|---|
product certifications | CE EAC | |
IP degree of protection | IP2x conforming to IEC 60529 | |
protective treatment | TH (pollution degree 3) conforming to IEC 60068-2-30 | |
pollution degree | 3 | |
ambient air temperature for operation | -5…55 °C | |
ambient air temperature for storage | -60…80 °C | |
permissible ambient air temperature around the device | -20…70 °C at Uc | |
operating altitude | 3000 m without derating | |
fire resistance | 850 °C conforming to IEC 60695-2-1 | |
mechanical robustness | Vibrations contactor open: 1.5 Gn, 5...300 Hz Vibrations contactor closed: 3 Gn, 5...300 Hz Shocks contactor open: 6 Gn for 11 ms Shocks contactor closed: 7 Gn for 11 ms |
Package 1 Weight | 1.400 g | |
---|---|---|
Package 1 Height | 121.000 mm | |
Package 1 width | 85.000 mm | |
Package 1 Length | 127.000 mm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
EU RoHS Directive | Compliant EU RoHS Declaration | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | China RoHS declaration Product out of China RoHS scope. Substance declaration for your information | |
Environmental Disclosure | ||
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Specifications for Schneider EasyPact TVS contactor 3P(3 NO) - AC-3 - 440 V 95A - 48 V AC coil
General Information | |
---|---|
# of Pole | 3 |
Arus Pengenal (A) | 95A |
Uncategorized | |
Coil AC | 48V (E7) |
range | EasyPact | |
---|---|---|
product name | EasyPact TVS | |
product or component type | Contactor | |
device short name | LC1E | |
contactor application | Resistive load Motor control | |
utilisation category | AC-3 AC-1 | |
poles description | 3P | |
power pole contact composition | 3 NO | |
[Ue] rated operational voltage | Power circuit: <= 690 V AC 50/60 Hz | |
[Ie] rated operational current | 95 A (at <55 °C) at <= 440 V AC AC-3 for power circuit 125 A (at <55 °C) at <= 440 V AC AC-1 for power circuit | |
motor power kW | 45 kW at 415 V 45 kW at 440 V 45 kW at 500 V 25 kW at 220...230 V AC 50/60 Hz 45 kW at 380...400 V 55 kW at 660...690 V | |
control circuit type | AC at 50/60 Hz | |
[Uc] control circuit voltage | 48 V AC 50/60 Hz | |
height | 127 mm | |
width | 85 mm | |
depth | 121 mm | |
net weight | 1.52 kg | |
colour | Grey (RAL 7011) |
auxiliary contact composition | 1 NO + 1 NC | |
---|---|---|
[Uimp] rated impulse withstand voltage | 6 kV coil not connected to the power circuit conforming to IEC 60947 | |
[Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 | |
overvoltage category | III | |
Irms rated making capacity | 950 A at 440 V AC for power circuit conforming to IEC 60947-4-1 | |
rated breaking capacity | 760 A at 440 V for power circuit conforming to IEC 60947 | |
[Icw] rated short-time withstand current | 135 A 40 °C - 600 s for power circuit 800 A 40 °C - 10 s for power circuit 400 A 40 °C - 60 s for power circuit | |
associated fuse rating | 10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1 160 A gG at <= 690 V coordination type 1 for power circuit | |
average impedance | 0.8 mOhm - Ith 120 A 50 Hz for power circuit | |
power dissipation per pole | 7.2 W AC-3 12 W AC-1 | |
control circuit voltage limits | Operational: 0.85...1.1 Uc at 50/60 Hz (at <55 °C) Drop-out: 0.3...0.6 Uc at 50/60 Hz (at <55 °C) | |
operating time | 20...35 ms on closing 6...30 ms on opening | |
mechanical durability | 300000 cycles | |
maximum operating rate | 1200 cyc/h 60 °C | |
inrush power in VA | 200 VA 50 Hz cos phi 0.75 (at 20 °C) 220 VA 60 Hz cos phi 0.75 (at 20 °C) | |
hold-in power consumption in VA | 22 VA 60 Hz cos phi 0.3 (at 20 °C) 20 VA 50 Hz cos phi 0.3 (at 20 °C) | |
heat dissipation | 6…10 W for control circuit | |
minimum switching current | 5 mA for control circuit | |
minimum switching voltage | 17 V for control circuit | |
non-overlap time | 1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact | |
insulation resistance | > 10 MOhm for control circuit | |
electrical durability | 350000 cycles AC-3 900000 cycles AC-1 | |
mounting support | Plate DIN rail | |
connections - terminals | Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 1 4…50 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 4…16 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 4…50 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 2 4…50 mm² - cable stiffness: solid without cable end | |
Recommended tightening torque | Control circuit: 1.2 N.m Power circuit: 12 N.m | |
Max tightening torque | Control circuit: 1.4 N.m Power circuit: 13.5 N.m |
standards | IEC 60947-5-1 IEC 60947-1 IEC 60947-4-1 | |
---|---|---|
product certifications | CE EAC | |
IP degree of protection | IP2x conforming to IEC 60529 | |
protective treatment | TH (pollution degree 3) conforming to IEC 60068-2-30 | |
pollution degree | 3 | |
ambient air temperature for operation | -5…55 °C | |
ambient air temperature for storage | -60…80 °C | |
permissible ambient air temperature around the device | -20…70 °C at Uc | |
operating altitude | 3000 m without derating | |
fire resistance | 850 °C conforming to IEC 60695-2-1 | |
mechanical robustness | Vibrations contactor open: 1.5 Gn, 5...300 Hz Vibrations contactor closed: 3 Gn, 5...300 Hz Shocks contactor open: 6 Gn for 11 ms Shocks contactor closed: 7 Gn for 11 ms |
Package 1 Weight | 1.400 g | |
---|---|---|
Package 1 Height | 121.000 mm | |
Package 1 width | 85.000 mm | |
Package 1 Length | 127.000 mm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
EU RoHS Directive | Compliant EU RoHS Declaration | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | China RoHS declaration Product out of China RoHS scope. Substance declaration for your information | |
Environmental Disclosure | ||
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Recently Viewed Products
Schneider EasyPact TVS contactor 3P(3 NO) - AC-3 - 440 V 95A - 48 V AC coil
Rp 2,951,046.00
Rp 1,670,586.00
Schneider Orange complete pilot light (D)22 plain lens with integral LED 110.120V
Rp 227,855.00
Rp 134,046.00
Schneider Blue complete pilot light (D)22 plain lens with integral LED 110 120V
Rp 391,025.00
Rp 230,039.00